title: "Delta SIG110 Bath Fan (110 CFM, 0.3 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/delta-sig110/
description: "ENERGY STAR specs for Delta SIG110: 110 CFM, 0.3 sones (#24 of 607), 9.0 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Delta SIG110 Exhaust Fan Specifications

ENERGY STAR PD #2249236 · Bathroom/Utility Room · Qualified 2015-10-01

Verified Specification Summary

Rated for 110 CFM open-air (96.5 CFM at 0.25 in. w.g.), Delta SIG110 registers #24 of 607 in quietness (0.3 sones) and delivers 9.0 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 96 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SIG110 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 96.5 CFM

- **Noise @ 0.1"**: 0.3 sones (#24/607)

- **Efficacy Rank**: 9.0 CFM/W (#298/1,145)

- **Static Retention**: 87.7% @ 0.25"

- **Motor Draw**: 12.2 W (4.5 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta SIG110 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.3 sones (#24 of 607 rated models, quietest 8.1% of 607 rated models, quieter than 91.9% of rated models, 0.70 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 96.5 CFM out of 110 CFM (87.7% retention, equal to the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Delta's 121-unit lineup, SIG110 (series: BreezSignature) carries PD #2249236 dating to 2015-10-01. Lighting kit: No. At 9.0 CFM/W (#298 of 1,145, top 26.1% of 1,145 rated models, more efficient than 73.9% of rated models, 4.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.2 watts, about 4.5 kWh/yr (~$0.72/yr at $0.16/kWh) for 1 hr/day shower timers or 106.9 kWh/yr (~$17.10/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-E110THA (110.0 CFM) and Delta 110LED-ADJ (110.0 CFM).

## How does Delta SIG110 acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Delta SIG110 (0.3 sones).

## How do flex elbows choke Delta SIG110 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Delta SIG110 moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Delta SIG110 meet residential exhaust fan code specs?

Inspect Delta SIG110 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SIG110 / BreezSignature | PD ID 2249236 (Qualified 2015-10-01) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (96.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.3 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Which bathroom duties match Delta SIG110 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Delta SIG110 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Delta SIG110

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 96 sq ft | 1 CFM/sq ft @ 96.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 85 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 46 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.5 kWh/yr (~$0.72/yr) | 12.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 106.9 kWh/yr (~$17.10/yr) | 12.2 W x 8,760 hrs / 1,000 |

## Which competing models share Delta SIG110 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Panasonic Eco Solutions RG-E110THA**](https://siematic-charleston.com/ventilation-fans/panasonic-eco-solutions-rg-e110tha/) | 110 / 110.3 CFM | 0.5 sones (+0.20) | 9.9 CFM/W | 4 in. diameter |
| [**Delta 110LED-ADJ**](https://siematic-charleston.com/ventilation-fans/delta-110led-adj/) | 110 / 98.1 CFM | 0.4 sones (+0.10) | 8.3 CFM/W | 4 in. diameter |
| [**Dayton 5AE70B**](https://siematic-charleston.com/ventilation-fans/dayton-5ae70b/) | 120 / N/A CFM | 0.5 sones (+0.20) | 6.2 CFM/W | 6 x 8 in. rectangular |
| [**Greenheck SP-A110**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-a110/) | 120 / 98 CFM | 0.1 sones (-0.20) | 6.2 CFM/W | 6 x 8 in. rectangular |
| [**Broan (Canada) XB110L1**](https://siematic-charleston.com/ventilation-fans/broan-canada-xb110l1/) | 110 / 110.3 CFM | 0.3 sones (Same) | 12.6 CFM/W | 6 in. diameter |

## How much airflow margin does Delta SIG110 give your bath?

Run a quick local room-volume check for Delta SIG110 by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Delta SIG110 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Delta SIG110 for residential use.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 46 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Ideal fit:** Bathroom floor <= 96 sq ft with 8-ft ceilings (85 sq ft at 9-ft height)
- **Primary match:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What should homeowners verify first about Delta SIG110?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Delta SIG110.

### Does Delta SIG110 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Delta SIG110 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Delta SIG110 undersized or poorly matched for a bath renovation?

Skip Delta SIG110 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Delta SIG110 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Delta SIG110 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

### How does Delta SIG110 sound output compare to noisy contractor-grade fans?

Rated at 0.3 sones, Delta SIG110 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Delta SIG110?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Delta SIG110 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SIG110's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta SIG110?

Delta SIG110 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta SIG110's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SIG110's safe coverage footprint from 50 sq ft to 44 sq ft.

## Which GradeMark tools pair best with Delta SIG110?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Delta SIG110.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Pennbarry ZQ110 6" Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/pennbarry-zq110-6/)
- [Broan RB80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-rb80/)
- [Broan XB110HL1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-xb110hl1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)