title: "Delta SIG80-110 Bath Fan (110 (10-2343169) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/delta-sig80-110-2343169/
description: "ENERGY STAR specs for Delta SIG80-110: 110 CFM, 10.5 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes, and."
---

#  Delta SIG80-110 Exhaust Fan Specifications

ENERGY STAR PD #2343169 · Bathroom/Utility Room · Qualified 2018-01-19

Verified Specification Summary

Homeowners specifying Delta SIG80-110 gain 110 CFM at 0.1 in. w.g. (110.7 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 10.5 CFM/W efficacy, venting bathrooms up to 110 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SIG80-110 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 110.7 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 10.5 CFM/W (#158/1,145)

- **Static Retention**: 100.6% @ 0.25"

- **Motor Draw**: 10.5 W (3.8 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Most Eff.

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta SIG80-110 vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta SIG80-110 (EPA filing PD #2343169) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 110.7 CFM out of 110 CFM (100.6% retention, 12.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Delta registers 121 certified models, with SKU SIG80-110 (series: BreezSignature) (PD #2343169) certified since 2018-01-19. Lighting kit: No. At 10.5 CFM/W (#158 of 1,145, top 14.8% of 1,145 rated models, more efficient than 85.2% of rated models, 5.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.5 watts, about 3.8 kWh/yr (~$0.61/yr at $0.16/kWh) for 1 hr/day shower timers or 92.0 kWh/yr (~$14.72/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

## Which exterior damper path suits Delta SIG80-110 best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Delta SIG80-110 housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Delta SIG80-110 acoustic and static metrics stand?

Compare Delta SIG80-110 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SIG80-110 / BreezSignature | PD ID 2343169 (Qualified 2018-01-19) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (110.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Delta SIG80-110 handle taller ceilings or walk-in tub steam?

Evaluate how Delta SIG80-110 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Delta SIG80-110

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 110 sq ft | 1 CFM/sq ft @ 110.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 98 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 60 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.8 kWh/yr (~$0.61/yr) | 10.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 92.0 kWh/yr (~$14.72/yr) | 10.5 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Delta SIG80-110?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**DewStop - Breeze Easy BEL110**](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-bel110/) | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| [**Revent RVL110**](https://siematic-charleston.com/ventilation-fans/revent-rvl110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| [**Revent RVLH110**](https://siematic-charleston.com/ventilation-fans/revent-rvlh110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |

## Is Delta SIG80-110 sized right for your shower or tub room?

Check whether Delta SIG80-110 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Delta SIG80-110 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Delta SIG80-110 carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 60 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Choose this if:** Moisture load fits 110.7 CFM net static output
- **Works well for:** Collar pairs with 4 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Delta SIG80-110?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Delta SIG80-110.

### How loud is Delta SIG80-110 compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Delta SIG80-110 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Delta SIG80-110 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Delta SIG80-110 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Delta SIG80-110 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SIG80-110's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta SIG80-110?

Delta SIG80-110 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta SIG80-110's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SIG80-110's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Delta SIG80-110 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Delta SIG80-110 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Delta SIG80-110?

Rule out Delta SIG80-110 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Delta SIG80-110 capacity?

Because static drag at 0.25 in. w.g. lowers Delta SIG80-110 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

## How can you cross-check Delta SIG80-110 against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Delta SIG80-110.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta SIG80-110D Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-sig80-110d/)
- [Delta SIG80-110D Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-sig80-110d-2343165/)
- [Delta SIG80-110 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-sig80-110/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)