#  Delta SIG80-110MH Exhaust Fan Specifications

ENERGY STAR PD #2343170 · Bathroom/Utility Room · Qualified 2018-01-19

Verified Specification Summary

Rated for 110 CFM open-air (110.9 CFM at 0.25 in. w.g.), Delta SIG80-110MH omits a published 0.1-inch sone rating and delivers 15.3 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 110 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SIG80-110MH Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 110.9 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 15.3 CFM/W (#24/1,145)

- **Static Retention**: 100.8% @ 0.25"

- **Motor Draw**: 7.2 W (2.6 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Most Eff.

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta SIG80-110MH vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta SIG80-110MH (EPA filing PD #2343170) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 110.9 CFM out of 110 CFM (100.8% retention, 13.1 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Certification audit confirms Delta SIG80-110MH (series: BreezSignature) under PD #2343170 (121 models registered, 2018-01-19). Lighting kit: No. At 15.3 CFM/W (#24 of 1,145, top 2.4% of 1,145 rated models, more efficient than 97.6% of rated models, 10.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.2 watts, about 2.6 kWh/yr (~$0.42/yr at $0.16/kWh) for 1 hr/day shower timers or 63.1 kWh/yr (~$10.10/yr) continuously. Closest competing matches include Panasonic FV-0511VKS3S (110.0 CFM) and Panasonic FV-0511VKSL3K (110.0 CFM).

## How do flex elbows choke Delta SIG80-110MH at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Delta SIG80-110MH moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Delta SIG80-110MH meet residential exhaust fan code specs?

Inspect Delta SIG80-110MH mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SIG80-110MH / BreezSignature | PD ID 2343170 (Qualified 2018-01-19) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (110.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Which bathroom duties match Delta SIG80-110MH airflow output?

Annual electricity figures and room square-footage ceilings below reflect Delta SIG80-110MH tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Delta SIG80-110MH

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 110 sq ft | 1 CFM/sq ft @ 110.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 98 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 60 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.6 kWh/yr (~$0.42/yr) | 7.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 63.1 kWh/yr (~$10.10/yr) | 7.2 W x 8,760 hrs / 1,000 |

## Which competing models share Delta SIG80-110MH airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Panasonic FV-0511VKS3S**](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vks3s/) | 110 / 111.9 CFM | Unpublished | 15.1 CFM/W | 6 in. diameter |
| [**Panasonic FV-0511VKSL3K**](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vksl3k/) | 110 / 111.1 CFM | Unpublished | 15.6 CFM/W | 6 in. diameter |
| [**Panasonic FV-0511VKL3**](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vkl3-3442063/) | 110 / 114.4 CFM | Unpublished | 15.7 CFM/W | 6 in. diameter |
| [**Panasonic FV-0511VKSL3**](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0511vksl3/) | 110 / 114.4 CFM | Unpublished | 15.7 CFM/W | 6 in. diameter |
| [**Broan-Nutone PTE511RK**](https://siematic-charleston.com/ventilation-fans/broan-nutone-pte511rk/) | 110 / 110.8 CFM | Unpublished | 14.5 CFM/W | 6 in. diameter |

## How much airflow margin does Delta SIG80-110MH give your bath?

Run a quick local room-volume check for Delta SIG80-110MH by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Delta SIG80-110MH in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Delta SIG80-110MH for residential use.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 60 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Ideal fit:** Bathroom floor <= 110 sq ft with 8-ft ceilings (98 sq ft at 9-ft height)
- **Primary match:** Exterior run uses smooth rigid metal matched to 6 in. diameter

## What should homeowners verify first about Delta SIG80-110MH?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Delta SIG80-110MH.

### Why check Delta SIG80-110MH CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Delta SIG80-110MH registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.

### How does Delta SIG80-110MH sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Delta SIG80-110MH produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Delta SIG80-110MH?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Delta SIG80-110MH pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SIG80-110MH's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta SIG80-110MH?

Delta SIG80-110MH features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta SIG80-110MH's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SIG80-110MH's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Delta SIG80-110MH satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Delta SIG80-110MH clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Delta SIG80-110MH undersized or poorly matched for a bath renovation?

Skip Delta SIG80-110MH if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

## Which GradeMark tools pair best with Delta SIG80-110MH?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Delta SIG80-110MH.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta SIG80-110MH Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-sig80-110mh-2343171/)
- [DewStop - Breeze Easy BEL5080110 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-bel5080110/)
- [Delta SIG80-110H Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-sig80-110h-2343167/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)