title: "Delta SIG80D Bath Fan (80 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/delta-sig80d/
description: "ENERGY STAR specs for Delta SIG80D: 80 CFM, 9.6 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes, and."
---

#  Delta SIG80D Exhaust Fan Specifications

ENERGY STAR PD #2249240 · Bathroom/Utility Room · Qualified 2015-10-01

Verified Specification Summary

Tested under HVI protocols, the Delta SIG80D exhaust unit achieves 80 CFM at 0.1 in. w.g. (80.4 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 9.6 CFM/W efficacy, covering standard baths up to 80 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SIG80D Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 80.4 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 9.6 CFM/W (#206/1,145)

- **Static Retention**: 100.5% @ 0.25"

- **Motor Draw**: 8.3 W (3.0 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta SIG80D vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta SIG80D (EPA filing PD #2249240) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 80.4 CFM out of 80 CFM (100.5% retention, 12.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Delta maintains 121 active ENERGY STAR blowers; SIG80D (series: BreezSignature) (PD #2249240) gained qualification on 2015-10-01. Lighting kit: No. At 9.6 CFM/W (#206 of 1,145, top 20.3% of 1,145 rated models, more efficient than 79.7% of rated models, 4.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 8.3 watts, about 3.0 kWh/yr (~$0.48/yr at $0.16/kWh) for 1 hr/day shower timers or 72.7 kWh/yr (~$11.63/yr) continuously. Closest competing matches include Utilitech 7142-70-L (70.0 CFM) and Delta VFB080B4A1-LVDC (80.0 CFM).

## What attic duct routing preserves Delta SIG80D CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Delta SIG80D, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Delta SIG80D measure up on airflow and noise ratings?

Each row below breaks down Delta SIG80D certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SIG80D / BreezSignature | PD ID 2249240 (Qualified 2015-10-01) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (80.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Delta SIG80D CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Delta SIG80D

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 80 sq ft | 1 CFM/sq ft @ 80.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 71 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 30 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.0 kWh/yr (~$0.48/yr) | 8.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 72.7 kWh/yr (~$11.63/yr) | 8.3 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Delta SIG80D?

Compare Delta SIG80D side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech 7142-70-L**](https://siematic-charleston.com/ventilation-fans/utilitech-7142-70-l/) | 70 / 55.5 CFM | 1.5 sones | 7.2 CFM/W | 3 in. diameter |
| [**Delta VFB080B4A1-LVDC**](https://siematic-charleston.com/ventilation-fans/delta-vfb080b4a1-lvdc/) | 80 / 61.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Delta ITG80**](https://siematic-charleston.com/ventilation-fans/delta-itg80/) | 80 / 68.3 CFM | 1.3 sones | 8.4 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-BN**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-bn/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## Can you size Delta SIG80D for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Delta SIG80D verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Delta SIG80D on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Delta SIG80D carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 80.4 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Choose this if:** Target comfort around ENERGY STAR sones up to 80 sq ft
- **Works well for:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Delta SIG80D?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Delta SIG80D.

### Will long attic ducting choke Delta SIG80D capacity?

Because static drag at 0.25 in. w.g. lowers Delta SIG80D from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Delta SIG80D compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Delta SIG80D produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Delta SIG80D consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Delta SIG80D draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Delta SIG80D pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SIG80D's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta SIG80D?

Delta SIG80D features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta SIG80D's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SIG80D's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Delta SIG80D score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Delta SIG80D delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Delta SIG80D?

Rule out Delta SIG80D when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

## What neighboring pages and tools support Delta SIG80D?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Delta SIG80D.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Nutone 744RNL Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/nutone-744rnl/)
- [PROJECT SOURCE 8768-DS-PS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/project-source-8768-ds-ps/)
- [Delta ITG80H Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-itg80h/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)