---
title: "Delta SLM50 Bath Fan (50 CFM, 1.0 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/delta-slm50/
description: "ENERGY STAR specs for Delta SLM50: 50 CFM, 1.0 sones (#265 of 607), 11.6 CFM/W, 3 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Delta SLM50 Exhaust Fan Specifications

ENERGY STAR PD #2255839 · Bathroom/Utility Room · Qualified 2015-12-31

Verified Specification Summary

Homeowners specifying Delta SLM50 gain 50 CFM at 0.1 in. w.g. (41.3 CFM at 0.25 in. w.g.) where it registers #265 of 607 in quietness (1.0 sones) and delivers 11.6 CFM/W efficacy, venting bathrooms up to 41 sq ft cleanly through 3 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SLM50 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 50 / 41.3 CFM

- **Noise @ 0.1"**: 1.0 sones (#265/607)

- **Efficacy Rank**: 11.6 CFM/W (#104/1,145)

- **Static Retention**: 82.6% @ 0.25"

- **Motor Draw**: 4.3 W (1.6 kWh/yr)

- **Duct & Tier**: 3 in. diameter · Most Eff.

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta SLM50 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 50 CFM open-air to 41.3 CFM at 0.25 in. w.g. (82.6% retention, 5.1 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Delta SLM50 (series: BreezSlim) under PD #2255839 (121 models registered, 2015-12-31). Lighting kit: No. At 11.6 CFM/W (#104 of 1,145, top 9.2% of 1,145 rated models, more efficient than 90.8% of rated models, 6.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 4.3 watts, about 1.6 kWh/yr (~$0.26/yr at $0.16/kWh) for 1 hr/day shower timers or 37.7 kWh/yr (~$6.03/yr) continuously. Closest competing matches include Hampton Bay 7114-02 (50.0 CFM) and HomeWerks Worldwide 7114-02-HW (50.0 CFM).

## What acoustic percentile does Delta SLM50 occupy among 1,145 bath blowers?

Inspect how Delta SLM50 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

## Which exterior damper path suits Delta SLM50 best?

Exterior roof or wall damper termination paired with insulated 3 in. diameter metal pipe prevents condensation buildup around Delta SLM50 housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Delta SLM50 acoustic and static metrics stand?

Compare Delta SLM50 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SLM50 / BreezSlim | PD ID 2255839 (Qualified 2015-12-31) |
| **Duct Connection** | 3 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | CONTINUOUS ONLY (41.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (1.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Delta SLM50 handle taller ceilings or walk-in tub steam?

Evaluate how Delta SLM50 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Delta SLM50

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 41 sq ft | 1 CFM/sq ft @ 41.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 36 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 1.6 kWh/yr (~$0.26/yr) | 4.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 37.7 kWh/yr (~$6.03/yr) | 4.3 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Delta SLM50?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Hampton Bay 7114-02**](https://siematic-charleston.com/ventilation-fans/hampton-bay-7114-02/) | 50 / 36.9 CFM | 1.0 sones (Same) | 10.2 CFM/W | 3 in. diameter |
| [**HomeWerks Worldwide 7114-02-HW**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7114-02-hw/) | 50 / 36.9 CFM | 1.0 sones (Same) | 10.2 CFM/W | 3 in. diameter |
| [**Utilitech 7114-02-L**](https://siematic-charleston.com/ventilation-fans/utilitech-7114-02-l/) | 50 / 36.9 CFM | 1.0 sones (Same) | 10.2 CFM/W | 3 in. diameter |
| [**Delta 50F**](https://siematic-charleston.com/ventilation-fans/delta-50f/) | 50 / 41.3 CFM | 1.0 sones (Same) | 11.6 CFM/W | 3 in. diameter |
| [**Revent RVS50**](https://siematic-charleston.com/ventilation-fans/revent-rvs50/) | 50 / 50 CFM | 1.0 sones (Same) | 9.1 CFM/W | 4 in. diameter |

## Is Delta SLM50 sized right for your shower or tub room?

Check whether Delta SLM50 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Delta SLM50?

Compare where Delta SLM50 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Supplementary continuous trickle ventilation
- **Suited to:** Collar pairs with 3 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Delta SLM50?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Delta SLM50.

### Is Delta SLM50 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Delta SLM50 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SLM50's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta SLM50?

Delta SLM50 features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta SLM50's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SLM50's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Delta SLM50 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Delta SLM50 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Delta SLM50 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Delta SLM50 lacks adequate reserve.

### How does Delta SLM50 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Delta SLM50 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 3 in. diameter rigid metal ducting protects real exhaust.

### Is Delta SLM50 quiet enough for a primary bedroom bathroom?

At 1.0 sones, Delta SLM50 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

## How can you cross-check Delta SLM50 against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Delta SLM50.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Hampton Bay 7114-02 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/hampton-bay-7114-02/)
- [HomeWerks Worldwide 7114-02-HW Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7114-02-hw/)
- [Delta 50F Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-50f/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
