title: "Delta SLM80-110D-C Bath Fan (110 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/delta-slm80-110d-c/
description: "ENERGY STAR specs for Delta SLM80-110D-C: 110 CFM, 8.0 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes."
---

#  Delta SLM80-110D-C Exhaust Fan Specifications

ENERGY STAR PD #2374794 · Bathroom/Utility Room · Qualified 2021-03-12

Verified Specification Summary

Certified by EPA ENERGY STAR, Delta SLM80-110D-C delivers 110 CFM free-air (114 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 8.0 CFM/W efficacy, clearing residential IRC M1505 sizing up to 114 sq ft (8-ft height) or 101 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SLM80-110D-C Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 114 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 8.0 CFM/W (#352/1,145)

- **Static Retention**: 103.6% @ 0.25"

- **Motor Draw**: 13.8 W (5.0 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta SLM80-110D-C vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta SLM80-110D-C (EPA filing PD #2374794) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 114 CFM out of 110 CFM (103.6% retention, 15.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Delta SLM80-110D-C (series: BreezSlim) under PD #2374794 (121 models registered, 2021-03-12). Lighting kit: No. At 8.0 CFM/W (#352 of 1,145, top 31.0% of 1,145 rated models, more efficient than 69.0% of rated models, 3.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.8 watts, about 5.0 kWh/yr (~$0.80/yr at $0.16/kWh) for 1 hr/day shower timers or 120.9 kWh/yr (~$19.34/yr) continuously. Closest competing matches include Utilitech UTLDS110 (110.0 CFM) and Utilitech 7115-02 (100.0 CFM).

## Why does rigid 4 in. diameter ducting protect Delta SLM80-110D-C airflow?

Connecting Delta SLM80-110D-C through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Delta SLM80-110D-C performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Delta SLM80-110D-C lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SLM80-110D-C / BreezSlim | PD ID 2374794 (Qualified 2021-03-12) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (114 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Delta SLM80-110D-C?

Calculated coverage metrics translate Delta SLM80-110D-C airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Delta SLM80-110D-C

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 114 sq ft | 1 CFM/sq ft @ 114 CFM |
| Tall Bath (9-ft Ceiling) | Up to 101 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 64 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.0 kWh/yr (~$0.80/yr) | 13.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 120.9 kWh/yr (~$19.34/yr) | 13.8 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Delta SLM80-110D-C?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-BN**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-bn/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-CH**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-ch/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-MB**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-mb/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## Does Delta SLM80-110D-C match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Delta SLM80-110D-C percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Delta SLM80-110D-C?

Match Delta SLM80-110D-C directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 64 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Best for:** Moisture load fits 114 CFM net static output
- **Optimal use:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for Delta SLM80-110D-C?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Delta SLM80-110D-C.

### What does Delta SLM80-110D-C cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Delta SLM80-110D-C 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Delta SLM80-110D-C pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SLM80-110D-C's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta SLM80-110D-C?

Delta SLM80-110D-C features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta SLM80-110D-C's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SLM80-110D-C's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can Delta SLM80-110D-C ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Delta SLM80-110D-C covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does Delta SLM80-110D-C run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Delta SLM80-110D-C.

### What happens to Delta SLM80-110D-C CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Delta SLM80-110D-C moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

### Where does Delta SLM80-110D-C sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Delta SLM80-110D-C produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

## Where can you explore more benchmarks around Delta SLM80-110D-C?

Use the related reference pages and estimators below to cross-check Delta SLM80-110D-C against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta SLM80-110DLED Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-slm80-110dled/)
- [Delta SLM80-110DLED-C Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-slm80-110dled-c/)
- [Delta SLM80-110D Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-slm80-110d/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)