#  Delta SLM80-110DLED Exhaust Fan Specifications

ENERGY STAR PD #2367520 · Bathroom/Utility Room · Qualified 2020-10-16

Verified Specification Summary

Certified by EPA ENERGY STAR, Delta SLM80-110DLED delivers 110 CFM free-air (108.5 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 7.1 CFM/W efficacy, clearing residential IRC M1505 sizing up to 108 sq ft (8-ft height) or 96 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SLM80-110DLED Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 108.5 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 7.1 CFM/W (#415/1,145)

- **Static Retention**: 98.6% @ 0.25"

- **Motor Draw**: 15.5 W (5.7 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta SLM80-110DLED vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta SLM80-110DLED (EPA filing PD #2367520) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 108.5 CFM out of 110 CFM (98.6% retention, 10.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2367520 verifies SLM80-110DLED (series: BreezSlim) under Delta (121 listed models, qualified 2020-10-16). Lighting kit: Yes. At 7.1 CFM/W (#415 of 1,145, top 36.6% of 1,145 rated models, more efficient than 63.4% of rated models, 2.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 15.5 watts, about 5.7 kWh/yr (~$0.91/yr at $0.16/kWh) for 1 hr/day shower timers or 135.8 kWh/yr (~$21.73/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-N110LHA (110.0 CFM) and Utilitech 7131-04 (100.0 CFM).

## Why does rigid 4 in. diameter ducting protect Delta SLM80-110DLED airflow?

Connecting Delta SLM80-110DLED through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Delta SLM80-110DLED performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Delta SLM80-110DLED lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SLM80-110DLED / BreezSlim | PD ID 2367520 (Qualified 2020-10-16) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (108.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What room sizes and annual power draw fit Delta SLM80-110DLED?

Calculated coverage metrics translate Delta SLM80-110DLED airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Delta SLM80-110DLED

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 108 sq ft | 1 CFM/sq ft @ 108.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 96 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 58 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.7 kWh/yr (~$0.91/yr) | 15.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 135.8 kWh/yr (~$21.73/yr) | 15.5 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Delta SLM80-110DLED?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Panasonic Eco Solutions RG-N110LHA**](https://siematic-charleston.com/ventilation-fans/panasonic-eco-solutions-rg-n110lha/) | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| [**Utilitech 7131-04**](https://siematic-charleston.com/ventilation-fans/utilitech-7131-04/) | 100 / 88 CFM | 1.5 sones | 7.6 CFM/W | 4 in. diameter |
| [**Utilitech 7115-01**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-01/) | 100 / 95.4 CFM | 1.5 sones | 6.5 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-BN**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-bn/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## Does Delta SLM80-110DLED match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Delta SLM80-110DLED percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Delta SLM80-110DLED in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Delta SLM80-110DLED for residential use.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 58 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Ideal fit:** Moisture load fits 108.5 CFM net static output
- **Primary match:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for Delta SLM80-110DLED?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Delta SLM80-110DLED.

### Does Delta SLM80-110DLED satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Delta SLM80-110DLED clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Delta SLM80-110DLED undersized or poorly matched for a bath renovation?

Skip Delta SLM80-110DLED if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Delta SLM80-110DLED CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Delta SLM80-110DLED registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

### How does Delta SLM80-110DLED sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Delta SLM80-110DLED produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Delta SLM80-110DLED?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Delta SLM80-110DLED pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SLM80-110DLED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta SLM80-110DLED?

Delta SLM80-110DLED features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta SLM80-110DLED's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SLM80-110DLED's safe coverage footprint from 50 sq ft to 44 sq ft.

## Where can you explore more benchmarks around Delta SLM80-110DLED?

Use the related reference pages and estimators below to cross-check Delta SLM80-110DLED against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta SLM80-110DLED-C Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-slm80-110dled-c/)
- [Delta SLM80-110H-C Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-slm80-110h-c/)
- [Delta SLM80-110D-C Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-slm80-110d-c/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)