#  Delta SLM80-110LED Exhaust Fan Specifications

ENERGY STAR PD #2367522 · Bathroom/Utility Room · Qualified 2020-10-16

Verified Specification Summary

Homeowners specifying Delta SLM80-110LED gain 110 CFM at 0.1 in. w.g. (108.5 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 7.1 CFM/W efficacy, venting bathrooms up to 108 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SLM80-110LED Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 108.5 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 7.1 CFM/W (#415/1,145)

- **Static Retention**: 98.6% @ 0.25"

- **Motor Draw**: 15.5 W (5.7 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta SLM80-110LED vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta SLM80-110LED (EPA filing PD #2367522) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 108.5 CFM out of 110 CFM (98.6% retention, 10.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Delta maintains 121 active ENERGY STAR blowers; SLM80-110LED (series: BreezSlim) (PD #2367522) gained qualification on 2020-10-16. Lighting kit: Yes. At 7.1 CFM/W (#415 of 1,145, top 36.6% of 1,145 rated models, more efficient than 63.4% of rated models, 2.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 15.5 watts, about 5.7 kWh/yr (~$0.91/yr at $0.16/kWh) for 1 hr/day shower timers or 135.8 kWh/yr (~$21.73/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-N110LHA (110.0 CFM) and Utilitech 7131-04 (100.0 CFM).

## Which exterior damper path suits Delta SLM80-110LED best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Delta SLM80-110LED housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Delta SLM80-110LED acoustic and static metrics stand?

Compare Delta SLM80-110LED published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SLM80-110LED / BreezSlim | PD ID 2367522 (Qualified 2020-10-16) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (108.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## Can Delta SLM80-110LED handle taller ceilings or walk-in tub steam?

Evaluate how Delta SLM80-110LED scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Delta SLM80-110LED

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 108 sq ft | 1 CFM/sq ft @ 108.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 96 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 58 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.7 kWh/yr (~$0.91/yr) | 15.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 135.8 kWh/yr (~$21.73/yr) | 15.5 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Delta SLM80-110LED?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Panasonic Eco Solutions RG-N110LHA**](https://siematic-charleston.com/ventilation-fans/panasonic-eco-solutions-rg-n110lha/) | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| [**Utilitech 7131-04**](https://siematic-charleston.com/ventilation-fans/utilitech-7131-04/) | 100 / 88 CFM | 1.5 sones | 7.6 CFM/W | 4 in. diameter |
| [**Utilitech 7115-01**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-01/) | 100 / 95.4 CFM | 1.5 sones | 6.5 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02-BN**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02-bn/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## Is Delta SLM80-110LED sized right for your shower or tub room?

Check whether Delta SLM80-110LED clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Delta SLM80-110LED on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Delta SLM80-110LED carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 58 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Choose this if:** Moisture load fits 108.5 CFM net static output
- **Works well for:** Collar pairs with 4 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Delta SLM80-110LED?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Delta SLM80-110LED.

### Will long attic ducting choke Delta SLM80-110LED capacity?

Because static drag at 0.25 in. w.g. lowers Delta SLM80-110LED from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Delta SLM80-110LED compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Delta SLM80-110LED produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Delta SLM80-110LED consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Delta SLM80-110LED draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Delta SLM80-110LED pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SLM80-110LED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta SLM80-110LED?

Delta SLM80-110LED features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta SLM80-110LED's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SLM80-110LED's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Delta SLM80-110LED score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Delta SLM80-110LED delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Delta SLM80-110LED?

Rule out Delta SLM80-110LED when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

## How can you cross-check Delta SLM80-110LED against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Delta SLM80-110LED.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta SLM80-110LED-C Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-slm80-110led-c/)
- [DewStop - Breeze Easy FL300-2W Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-fl300-2w/)
- [Delta SLM80-110H-C Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-slm80-110h-c/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)