title: "Delta SMT130 Bath Fan (130 CFM, 0.0 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/delta-smt130/
description: "ENERGY STAR specs for Delta SMT130: 130 CFM, 0.0 sones (#1 of 607), 11.4 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Delta SMT130 Exhaust Fan Specifications

ENERGY STAR PD #2287981 · Bathroom/Utility Room · Qualified 2017-01-06

Verified Specification Summary

Tested under HVI protocols, the Delta SMT130 exhaust unit achieves 130 CFM at 0.1 in. w.g. (126.3 CFM at 0.25 in. w.g.), registers #1 of 607 in quietness (0.0 sones) and delivers 11.4 CFM/W efficacy, covering standard baths up to 126 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SMT130 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 130 / 126.3 CFM

- **Noise @ 0.1"**: 0.0 sones (#1/607)

- **Efficacy Rank**: 11.4 CFM/W (#115/1,145)

- **Static Retention**: 97.2% @ 0.25"

- **Motor Draw**: 11.4 W (4.2 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta SMT130 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.0 sones (#1 of 607 rated models, quietest 1.5% of 607 rated models, quieter than 98.5% of rated models, 1.00 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 126.3 CFM out of 130 CFM (97.2% retention, 9.5 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #2287981 verifies SMT130 (series: BreezSmart) under Delta (121 listed models, qualified 2017-01-06). Lighting kit: No. At 11.4 CFM/W (#115 of 1,145, top 10.7% of 1,145 rated models, more efficient than 89.3% of rated models, 6.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.4 watts, about 4.2 kWh/yr (~$0.67/yr at $0.16/kWh) for 1 hr/day shower timers or 99.9 kWh/yr (~$15.98/yr) continuously. Closest competing matches include Panasonic RG-E130A (130.0 CFM) and Broan (Canada) XB110L1 (110.0 CFM).

## Where do Delta SMT130 sones rank across EPA ENERGY STAR fans?

Comparing Delta SMT130 (0.0 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves Delta SMT130 CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Delta SMT130, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Delta SMT130 measure up on airflow and noise ratings?

Each row below breaks down Delta SMT130 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SMT130 / BreezSmart | PD ID 2287981 (Qualified 2017-01-06) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (126.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Delta SMT130 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Delta SMT130

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 126 sq ft | 1 CFM/sq ft @ 126.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 112 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 76 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.2 kWh/yr (~$0.67/yr) | 11.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 99.9 kWh/yr (~$15.98/yr) | 11.4 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Delta SMT130?

Compare Delta SMT130 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Panasonic RG-E130A**](https://siematic-charleston.com/ventilation-fans/panasonic-rg-e130a/) | 130 / 132 CFM | 0.4 sones (+0.40) | 12.5 CFM/W | 6 in. diameter |
| [**Broan (Canada) XB110L1**](https://siematic-charleston.com/ventilation-fans/broan-canada-xb110l1/) | 110 / 110.3 CFM | 0.3 sones (+0.30) | 12.6 CFM/W | 6 in. diameter |
| [**Broan XB110HL1**](https://siematic-charleston.com/ventilation-fans/broan-xb110hl1/) | 110 / 110.3 CFM | 0.3 sones (+0.30) | 12.6 CFM/W | 6 in. diameter |
| [**Pennbarry ZQ110 6"**](https://siematic-charleston.com/ventilation-fans/pennbarry-zq110-6/) | 110 / N/A CFM | 0.3 sones (+0.30) | 13.1 CFM/W | 8 in. diameter |
| [**Broan XB110=XB000HwithXB110F**](https://siematic-charleston.com/ventilation-fans/broan-xb110-xb000hwithxb110f/) | 110 / 110.2 CFM | 0.1 sones (+0.10) | 14.3 CFM/W | 6 in. diameter |

## Can you size Delta SMT130 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Delta SMT130 verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Delta SMT130?

Match Delta SMT130 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 126.3 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Best for:** Target comfort around 0.0 sones up to 126 sq ft
- **Optimal use:** Paired with rigid galvanized 6 in. diameter transition

## How do federal and code standards apply to Delta SMT130?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Delta SMT130.

### What bathroom square footage can Delta SMT130 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Delta SMT130 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does Delta SMT130 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Delta SMT130.

### What happens to Delta SMT130 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Delta SMT130 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.

### Where does Delta SMT130 sit on acoustic comfort for senior homeowners?

Measuring 0.0 sones, Delta SMT130 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Delta SMT130 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Delta SMT130 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Delta SMT130 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SMT130's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta SMT130?

Delta SMT130 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta SMT130's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SMT130's safe coverage footprint from 50 sq ft to 44 sq ft.

## What neighboring pages and tools support Delta SMT130?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Delta SMT130.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Best HBN223012SS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/best-hbn223012ss/)
- [Best HBN223612SS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/best-hbn223612ss/)
- [Best HBN566212SS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/best-hbn566212ss/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)