#  Delta SMT130H Exhaust Fan Specifications

ENERGY STAR PD #2287982 · Bathroom/Utility Room · Qualified 2017-01-06

Verified Specification Summary

In EPA dataset 8dv7-nngq, Delta SMT130H tests at 130 CFM free discharge (126.3 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 11.4 CFM/W efficacy, meeting residential IRC M1505 sizing up to 126 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SMT130H Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 130 / 126.3 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 11.4 CFM/W (#115/1,145)

- **Static Retention**: 97.2% @ 0.25"

- **Motor Draw**: 11.4 W (4.2 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Delta SMT130H vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta SMT130H (EPA filing PD #2287982) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 126.3 CFM out of 130 CFM (97.2% retention, 9.5 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #2287982 verifies SMT130H (series: BreezSmart) under Delta (121 listed models, qualified 2017-01-06). Lighting kit: No. At 11.4 CFM/W (#115 of 1,145, top 10.7% of 1,145 rated models, more efficient than 89.3% of rated models, 6.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.4 watts, about 4.2 kWh/yr (~$0.67/yr at $0.16/kWh) for 1 hr/day shower timers or 99.9 kWh/yr (~$15.98/yr) continuously. Closest competing matches include Loren Cook Company GCVF 100 (127.0 CFM) and Utilitech UTLDR110 (110.0 CFM).

## Why avoid unvented attic termination with Delta SMT130H?

Under ASHRAE 62.2 best practice, Delta SMT130H needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Delta SMT130H?

Before cutting ceiling drywall or sizing attic transitions for Delta SMT130H, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Delta (121 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SMT130H / BreezSmart | PD ID 2287982 (Qualified 2017-01-06) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (126.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit Delta SMT130H?

Bathroom ventilation sizing below maps Delta SMT130H motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Delta SMT130H

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 126 sq ft | 1 CFM/sq ft @ 126.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 112 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 76 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.2 kWh/yr (~$0.67/yr) | 11.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 99.9 kWh/yr (~$15.98/yr) | 11.4 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Delta SMT130H in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Delta SMT130H.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Loren Cook Company GCVF 100**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gcvf-100/) | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Revent RVL110**](https://siematic-charleston.com/ventilation-fans/revent-rvl110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| [**Revent RVLH110**](https://siematic-charleston.com/ventilation-fans/revent-rvlh110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| [**DewStop - Breeze Easy BEL110**](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-bel110/) | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |

## What percentage of room demand does Delta SMT130H cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Delta SMT130H tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Delta SMT130H?

Compare where Delta SMT130H excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 126.3 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Target comfort around ENERGY STAR sones up to 126 sq ft
- **Suited to:** Paired with rigid galvanized 6 in. diameter transition

## Where do official rules set limits for Delta SMT130H?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Delta SMT130H.

### Is Delta SMT130H quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Delta SMT130H produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Delta SMT130H energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Delta SMT130H pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SMT130H's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Delta SMT130H?

Delta SMT130H features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Delta SMT130H's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SMT130H's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Delta SMT130H serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Delta SMT130H supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Delta SMT130H for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Delta SMT130H lacks adequate reserve.

### How does Delta SMT130H handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Delta SMT130H yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

## What related resources expand on Delta SMT130H?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Delta SMT130M Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-smt130m/)
- [KOHLER 34454 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kohler-34454/)
- [Broan PM400SS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-pm400ss/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)