title: "Fantech FG 12XL EC Bath Fan (750 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/fantech-fg-12xl-ec/
description: "ENERGY STAR specs for Fantech FG 12XL EC: 750 CFM, 4.6 CFM/W, 12 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes."
---

#  Fantech FG 12XL EC Exhaust Fan Specifications

ENERGY STAR PD #2349680 · In-line (single-port) · Qualified 2019-11-08

Verified Specification Summary

The Fantech FG 12XL EC (FG 12XL EC) moves 750 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating, and delivers 4.6 CFM/W efficacy, sizing bathrooms up to 750 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech FG 12XL EC Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 750 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.6 CFM/W (#578/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 163.0 W (59.5 kWh/yr)

- **Duct & Tier**: 12 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Fantech FG 12XL EC vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech FG 12XL EC (EPA filing PD #2349680) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 750 CFM (#1 of 1,145 certified models) via a 12 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 12 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Fantech registers 52 certified models, with SKU FG 12XL EC (series: FG 12XL EC) (PD #2349680) certified since 2019-11-08. Lighting kit: No. At 4.6 CFM/W (#578 of 1,145, below median tier among 1,145 rated models; more efficient than 44.9% of rated models, 0.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 163.0 watts, about 59.5 kWh/yr (~$9.52/yr at $0.16/kWh) for 1 hr/day shower timers or 1427.9 kWh/yr (~$228.46/yr) continuously. Closest competing matches include Delta VDBFRS200HT (200.0 CFM) and Delta VDBFRS200HT-P (200.0 CFM).

## How does duct geometry alter Fantech FG 12XL EC static pressure?

Smooth 12 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Fantech FG 12XL EC?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Fantech FG 12XL EC alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Fantech (52 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FG 12XL EC / FG 12XL EC | PD ID 2349680 (Qualified 2019-11-08) |
| **Duct Connection** | 12 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (750 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can Fantech FG 12XL EC ventilate safely?

Sizing outputs below convert Fantech FG 12XL EC tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Fantech FG 12XL EC

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 750 sq ft | 1 CFM/sq ft @ 750 CFM |
| Tall Bath (9-ft Ceiling) | Up to 666 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 700 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 59.5 kWh/yr (~$9.52/yr) | 163.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 1427.9 kWh/yr (~$228.46/yr) | 163.0 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Fantech FG 12XL EC closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta VDBFRS200HT**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200ht/) | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| [**Delta VDBFRS200HT-P**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200ht-p/) | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| [**Delta VDBFRS200**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200/) | 200 / N/A CFM | Unpublished | 5.3 CFM/W | 6 in. diameter |
| [**Delta VDB200**](https://siematic-charleston.com/ventilation-fans/delta-vdb200/) | 200 / N/A CFM | Unpublished | 6.6 CFM/W | 6 in. diameter |
| [**Best HBN536212SS**](https://siematic-charleston.com/ventilation-fans/best-hbn536212ss/) | 200 / N/A CFM | 0.0 sones | 16.6 CFM/W | 10 in. diameter |

## Will Fantech FG 12XL EC clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Fantech FG 12XL EC satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Fantech FG 12XL EC on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Fantech FG 12XL EC carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 700 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Choose this if:** Bathroom floor <= 750 sq ft with 8-ft ceilings (666 sq ft at 9-ft height)
- **Works well for:** Exterior run uses smooth rigid metal matched to 12 in. diameter

## What key rules and numbers govern Fantech FG 12XL EC?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Fantech FG 12XL EC.

### What duct and room conditions disqualify Fantech FG 12XL EC?

Rule out Fantech FG 12XL EC when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Fantech FG 12XL EC capacity?

Because static drag at 0.25 in. w.g. lowers Fantech FG 12XL EC from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 12 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Fantech FG 12XL EC compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Fantech FG 12XL EC produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Fantech FG 12XL EC consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Fantech FG 12XL EC draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Fantech FG 12XL EC pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech FG 12XL EC's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Fantech FG 12XL EC?

Fantech FG 12XL EC features a 12 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Fantech FG 12XL EC's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech FG 12XL EC's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Fantech FG 12XL EC score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Fantech FG 12XL EC delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

## Which guides and calculators connect next to Fantech FG 12XL EC?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Fantech FG 12XL EC.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Ortech OIF10-670 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ortech-oif10-670/)
- [Fantech FG 10 EC Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-fg-10-ec/)
- [Air King AK280LS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-ak280ls/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)