#  Fantech FG 4 (40402) Exhaust Fan Specifications

ENERGY STAR PD #2394306 · In-line (single-port) · Qualified 2022-04-01

Verified Specification Summary

The Fantech FG 4 (40402) (FG Series) moves 100 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating, and delivers 5.5 CFM/W efficacy, sizing bathrooms up to 100 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech FG 4 (40402) Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 5.5 CFM/W (#471/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 18.2 W (6.6 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Fantech FG 4 (40402) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech FG 4 (40402) (EPA filing PD #2394306) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 100 CFM (#621 of 1,145 certified models) via a 4 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Fantech's 52-unit lineup, FG 4 (40402) (series: FG Series) carries PD #2394306 dating to 2022-04-01. Lighting kit: No. At 5.5 CFM/W (#471 of 1,145, top 42.8% of 1,145 rated models, more efficient than 57.2% of rated models, 0.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.2 watts, about 6.6 kWh/yr (~$1.06/yr at $0.16/kWh) for 1 hr/day shower timers or 159.4 kWh/yr (~$25.50/yr) continuously. Closest competing matches include Utilitech 7115-01 (100.0 CFM) and ACIQ AES100 (100.0 CFM).

## How does duct geometry alter Fantech FG 4 (40402) static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Fantech FG 4 (40402)?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Fantech FG 4 (40402) alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Fantech (52 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FG 4 (40402) / FG Series | PD ID 2394306 (Qualified 2022-04-01) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (100 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can Fantech FG 4 (40402) ventilate safely?

Sizing outputs below convert Fantech FG 4 (40402) tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Fantech FG 4 (40402)

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 100 sq ft | 1 CFM/sq ft @ 100 CFM |
| Tall Bath (9-ft Ceiling) | Up to 88 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 50 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.6 kWh/yr (~$1.06/yr) | 18.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 159.4 kWh/yr (~$25.50/yr) | 18.2 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Fantech FG 4 (40402) closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech 7115-01**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-01/) | 100 / 95.4 CFM | 1.5 sones | 6.5 CFM/W | 4 in. diameter |
| [**ACIQ AES100**](https://siematic-charleston.com/ventilation-fans/aciq-aes100/) | 100 / 90.2 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**CFM TF100N**](https://siematic-charleston.com/ventilation-fans/cfm-tf100n/) | 100 / 90.2 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**S&P PCLP100XP**](https://siematic-charleston.com/ventilation-fans/s-p-pclp100xp/) | 100 / 90.2 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Panasonic Eco Solutions RG-N110LHA**](https://siematic-charleston.com/ventilation-fans/panasonic-eco-solutions-rg-n110lha/) | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |

## Will Fantech FG 4 (40402) clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Fantech FG 4 (40402) satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Fantech FG 4 (40402) in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Fantech FG 4 (40402) for residential use.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 50 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Ideal fit:** Bathroom floor <= 100 sq ft with 8-ft ceilings (88 sq ft at 9-ft height)
- **Primary match:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern Fantech FG 4 (40402)?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Fantech FG 4 (40402).

### How does Fantech FG 4 (40402) sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Fantech FG 4 (40402) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Fantech FG 4 (40402)?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Fantech FG 4 (40402) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech FG 4 (40402)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Fantech FG 4 (40402)?

Fantech FG 4 (40402) features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Fantech FG 4 (40402)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech FG 4 (40402)'s safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Fantech FG 4 (40402) satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Fantech FG 4 (40402) clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Fantech FG 4 (40402) undersized or poorly matched for a bath renovation?

Skip Fantech FG 4 (40402) if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Fantech FG 4 (40402) CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Fantech FG 4 (40402) registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

## Which guides and calculators connect next to Fantech FG 4 (40402)?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Fantech FG 4 (40402).

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Fantech FGC 4 (40420) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-fgc-4-40420/)
- [Fantech PB110 (40568) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-pb110-40568/)
- [Delta SLM50-100LED Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-slm50-100led/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)