title: "Fantech FG 4XL EC (56015) Bath Fan (160 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/fantech-fg-4xl-ec-56015/
description: "ENERGY STAR specs for Fantech FG 4XL EC (56015): 160 CFM, 4.8 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering."
---

#  Fantech FG 4XL EC (56015) Exhaust Fan Specifications

ENERGY STAR PD #2669947 · In-line (single-port) · Qualified 2023-09-29

Verified Specification Summary

Certified by EPA ENERGY STAR, Fantech FG 4XL EC (56015) delivers 160 CFM free-air (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 4.8 CFM/W efficacy, clearing residential IRC M1505 sizing up to 160 sq ft (8-ft height) or 142 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech FG 4XL EC (56015) Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 160 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.8 CFM/W (#534/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 33.3 W (12.2 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Fantech FG 4XL EC (56015) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech FG 4XL EC (56015) (EPA filing PD #2669947) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 160 CFM (#84 of 1,145 certified models) via a 4 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Fantech's 52-unit lineup, FG 4XL EC (56015) (series: FG EC Series) carries PD #2669947 dating to 2023-09-29. Lighting kit: No. At 4.8 CFM/W (#534 of 1,145, top 47.5% of 1,145 rated models, more efficient than 52.5% of rated models, 0.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 33.3 watts, about 12.2 kWh/yr (~$1.95/yr at $0.16/kWh) for 1 hr/day shower timers or 291.7 kWh/yr (~$46.67/yr) continuously. Closest competing matches include Broan QT150LE (150.0 CFM) and Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM).

## Why does rigid 4 in. diameter ducting protect Fantech FG 4XL EC (56015) airflow?

Connecting Fantech FG 4XL EC (56015) through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Fantech FG 4XL EC (56015) performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Fantech FG 4XL EC (56015) lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Fantech (52 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FG 4XL EC (56015) / FG EC Series | PD ID 2669947 (Qualified 2023-09-29) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (160 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Fantech FG 4XL EC (56015)?

Calculated coverage metrics translate Fantech FG 4XL EC (56015) airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Fantech FG 4XL EC (56015)

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 160 sq ft | 1 CFM/sq ft @ 160 CFM |
| Tall Bath (9-ft Ceiling) | Up to 142 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 110 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.2 kWh/yr (~$1.95/yr) | 33.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 291.7 kWh/yr (~$46.67/yr) | 33.3 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Fantech FG 4XL EC (56015)?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan QT150LE**](https://siematic-charleston.com/ventilation-fans/broan-qt150le/) | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Tech Drive TD-BF-24L-5CCT(BL)**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-24l-5cct-bl/) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Broan ALT4306SS**](https://siematic-charleston.com/ventilation-fans/broan-alt4306ss/) | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |
| [**Loren Cook Company GC-242**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gc-242/) | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| [**OREiN OL1700376**](https://siematic-charleston.com/ventilation-fans/orein-ol1700376/) | 160 / 152 CFM | 1.0 sones | 4.8 CFM/W | 6 in. diameter |

## Does Fantech FG 4XL EC (56015) match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Fantech FG 4XL EC (56015) percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Fantech FG 4XL EC (56015) suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Fantech FG 4XL EC (56015) for your remodel.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 110 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Strong scenario:** Moisture load fits 160 CFM net static output
- **Best application:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for Fantech FG 4XL EC (56015)?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Fantech FG 4XL EC (56015).

### Does Fantech FG 4XL EC (56015) pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Fantech FG 4XL EC (56015) easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Fantech FG 4XL EC (56015) in a bathroom remodel?

Avoid specifying Fantech FG 4XL EC (56015) in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Fantech FG 4XL EC (56015) airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Fantech FG 4XL EC (56015) achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Fantech FG 4XL EC (56015) occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Fantech FG 4XL EC (56015) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

### How many kWh per year does Fantech FG 4XL EC (56015) add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Fantech FG 4XL EC (56015) averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Fantech FG 4XL EC (56015) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech FG 4XL EC (56015)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Fantech FG 4XL EC (56015)?

Fantech FG 4XL EC (56015) features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Fantech FG 4XL EC (56015)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech FG 4XL EC (56015)'s safe coverage footprint from 50 sq ft to 44 sq ft.

## Where can you explore more benchmarks around Fantech FG 4XL EC (56015)?

Use the related reference pages and estimators below to cross-check Fantech FG 4XL EC (56015) against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Revent RVSC120140160 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/revent-rvsc120140160/)
- [S&P TD-125 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/s-p-td-125/)
- [Commercial Electric BF1115 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/commercial-electric-bf1115/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)