title: "Fantech FG 6M EC Bath Fan (330 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/fantech-fg-6m-ec/
description: "ENERGY STAR specs for Fantech FG 6M EC: 330 CFM, 4.4 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes, and."
---

#  Fantech FG 6M EC Exhaust Fan Specifications

ENERGY STAR PD #2346010 · In-line (single-port) · Qualified 2019-09-06

Verified Specification Summary

Certified by EPA ENERGY STAR, Fantech FG 6M EC delivers 330 CFM free-air (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 4.4 CFM/W efficacy, clearing residential IRC M1505 sizing up to 330 sq ft (8-ft height) or 293 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech FG 6M EC Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 330 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.4 CFM/W (#679/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 75.0 W (27.4 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Fantech FG 6M EC vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech FG 6M EC (EPA filing PD #2346010) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 330 CFM (#13 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Manufacturer coverage places FG 6M EC (series: FG 6M EC) (PD #2346010) among 52 Fantech entries qualified through 2019-09-06. Lighting kit: No. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 75.0 watts, about 27.4 kWh/yr (~$4.38/yr at $0.16/kWh) for 1 hr/day shower timers or 657.0 kWh/yr (~$105.12/yr) continuously. Closest competing matches include Delta VDBFRS200HT (200.0 CFM) and Delta VDBFRS200HT-P (200.0 CFM).

## Why does rigid 6 in. diameter ducting protect Fantech FG 6M EC airflow?

Connecting Fantech FG 6M EC through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Fantech FG 6M EC performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Fantech FG 6M EC lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Fantech (52 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FG 6M EC / FG 6M EC | PD ID 2346010 (Qualified 2019-09-06) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (330 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Fantech FG 6M EC?

Calculated coverage metrics translate Fantech FG 6M EC airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Fantech FG 6M EC

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 330 sq ft | 1 CFM/sq ft @ 330 CFM |
| Tall Bath (9-ft Ceiling) | Up to 293 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 280 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 27.4 kWh/yr (~$4.38/yr) | 75.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 657.0 kWh/yr (~$105.12/yr) | 75.0 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Fantech FG 6M EC?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta VDBFRS200HT**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200ht/) | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| [**Delta VDBFRS200HT-P**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200ht-p/) | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| [**Delta VDBFRS200**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200/) | 200 / N/A CFM | Unpublished | 5.3 CFM/W | 6 in. diameter |
| [**Delta VDB200**](https://siematic-charleston.com/ventilation-fans/delta-vdb200/) | 200 / N/A CFM | Unpublished | 6.6 CFM/W | 6 in. diameter |
| [**Broan FIN-180B**](https://siematic-charleston.com/ventilation-fans/broan-fin-180b/) | 180 / N/A CFM | Unpublished | 6.8 CFM/W | 6 in. diameter |

## Does Fantech FG 6M EC match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Fantech FG 6M EC percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Fantech FG 6M EC suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Fantech FG 6M EC for your remodel.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 280 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Strong scenario:** Moisture load fits 330 CFM net static output
- **Best application:** Collar pairs with 6 in. diameter duct straight outdoors

## Which homeowner questions come up most for Fantech FG 6M EC?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Fantech FG 6M EC.

### Does Fantech FG 6M EC pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Fantech FG 6M EC easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Fantech FG 6M EC in a bathroom remodel?

Avoid specifying Fantech FG 6M EC in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Fantech FG 6M EC airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Fantech FG 6M EC achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Fantech FG 6M EC occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Fantech FG 6M EC produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

### How many kWh per year does Fantech FG 6M EC add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Fantech FG 6M EC averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Fantech FG 6M EC pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech FG 6M EC's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Fantech FG 6M EC?

Fantech FG 6M EC features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Fantech FG 6M EC's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech FG 6M EC's safe coverage footprint from 50 sq ft to 44 sq ft.

## Where can you explore more benchmarks around Fantech FG 6M EC?

Use the related reference pages and estimators below to cross-check Fantech FG 6M EC against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Fantech FGC 6M EC Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-fgc-6m-ec/)
- [Broan L300E Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-l300e/)
- [Ortech OIF8-560 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ortech-oif8-560/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)