title: "Fantech FG 8 (40408) Bath Fan (390 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/fantech-fg-8-40408/
description: "ENERGY STAR specs for Fantech FG 8 (40408): 390 CFM, 4.0 CFM/W, 8 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes."
---

#  Fantech FG 8 (40408) Exhaust Fan Specifications

ENERGY STAR PD #4016345 · In-line (single-port) · Qualified 2025-04-25

Verified Specification Summary

Certified by EPA ENERGY STAR, Fantech FG 8 (40408) delivers 390 CFM free-air (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 4.0 CFM/W efficacy, clearing residential IRC M1505 sizing up to 390 sq ft (8-ft height) or 346 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech FG 8 (40408) Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 390 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.0 CFM/W (#847/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 97.5 W (35.6 kWh/yr)

- **Duct & Tier**: 8 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Fantech FG 8 (40408) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech FG 8 (40408) (EPA filing PD #4016345) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 390 CFM (#7 of 1,145 certified models) via a 8 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 8 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Fantech registers 52 certified models, with SKU FG 8 (40408) (series: FG Series) (PD #4016345) certified since 2025-04-25. Lighting kit: No. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 97.5 watts, about 35.6 kWh/yr (~$5.70/yr at $0.16/kWh) for 1 hr/day shower timers or 854.1 kWh/yr (~$136.66/yr) continuously. Closest competing matches include Delta VDBFRS200HT (200.0 CFM) and Delta VDBFRS200HT-P (200.0 CFM).

## Why does rigid 8 in. diameter ducting protect Fantech FG 8 (40408) airflow?

Connecting Fantech FG 8 (40408) through rigid 8 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Fantech FG 8 (40408) performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Fantech FG 8 (40408) lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Fantech (52 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FG 8 (40408) / FG Series | PD ID 4016345 (Qualified 2025-04-25) |
| **Duct Connection** | 8 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (390 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Fantech FG 8 (40408)?

Calculated coverage metrics translate Fantech FG 8 (40408) airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Fantech FG 8 (40408)

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 390 sq ft | 1 CFM/sq ft @ 390 CFM |
| Tall Bath (9-ft Ceiling) | Up to 346 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 340 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 35.6 kWh/yr (~$5.70/yr) | 97.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 854.1 kWh/yr (~$136.66/yr) | 97.5 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Fantech FG 8 (40408)?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta VDBFRS200HT**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200ht/) | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| [**Delta VDBFRS200HT-P**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200ht-p/) | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| [**Delta VDBFRS200**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200/) | 200 / N/A CFM | Unpublished | 5.3 CFM/W | 6 in. diameter |
| [**Delta VDB200**](https://siematic-charleston.com/ventilation-fans/delta-vdb200/) | 200 / N/A CFM | Unpublished | 6.6 CFM/W | 6 in. diameter |
| [**Broan FIN-180B**](https://siematic-charleston.com/ventilation-fans/broan-fin-180b/) | 180 / N/A CFM | Unpublished | 6.8 CFM/W | 6 in. diameter |

## Does Fantech FG 8 (40408) match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Fantech FG 8 (40408) percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Fantech FG 8 (40408) on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Fantech FG 8 (40408) carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 340 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Choose this if:** Moisture load fits 390 CFM net static output
- **Works well for:** Collar pairs with 8 in. diameter duct straight outdoors

## Which homeowner questions come up most for Fantech FG 8 (40408)?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Fantech FG 8 (40408).

### How does Fantech FG 8 (40408) score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Fantech FG 8 (40408) delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

### What duct and room conditions disqualify Fantech FG 8 (40408)?

Rule out Fantech FG 8 (40408) when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Fantech FG 8 (40408) capacity?

Because static drag at 0.25 in. w.g. lowers Fantech FG 8 (40408) from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 8 in. diameter rigid ducting straight to a dedicated exterior damper.

### How loud is Fantech FG 8 (40408) compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Fantech FG 8 (40408) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Fantech FG 8 (40408) consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Fantech FG 8 (40408) draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Fantech FG 8 (40408) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech FG 8 (40408)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Fantech FG 8 (40408)?

Fantech FG 8 (40408) features a 8 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Fantech FG 8 (40408)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech FG 8 (40408)'s safe coverage footprint from 50 sq ft to 44 sq ft.

## Where can you explore more benchmarks around Fantech FG 8 (40408)?

Use the related reference pages and estimators below to cross-check Fantech FG 8 (40408) against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Fantech FGC 8 (40423) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-fgc-8-40423/)
- [Greenheck CSP-A390-VG Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-csp-a390-vg/)
- [S&P TD-200 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/s-p-td-200/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)