title: "Fantech FGC 4 (40420) Bath Fan (100 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/fantech-fgc-4-40420/
description: "ENERGY STAR specs for Fantech FGC 4 (40420): 100 CFM, 5.5 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering."
---

#  Fantech FGC 4 (40420) Exhaust Fan Specifications

ENERGY STAR PD #2394294 · In-line (single-port) · Qualified 2022-04-01

Verified Specification Summary

Tested under HVI protocols, the Fantech FGC 4 (40420) exhaust unit achieves 100 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating and delivers 5.5 CFM/W efficacy, covering standard baths up to 100 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech FGC 4 (40420) Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 5.5 CFM/W (#471/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 18.2 W (6.6 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Fantech FGC 4 (40420) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech FGC 4 (40420) (EPA filing PD #2394294) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 100 CFM (#621 of 1,145 certified models) via a 4 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Fantech registers 52 certified models, with SKU FGC 4 (40420) (series: FG Series) (PD #2394294) certified since 2022-04-01. Lighting kit: No. At 5.5 CFM/W (#471 of 1,145, top 42.8% of 1,145 rated models, more efficient than 57.2% of rated models, 0.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.2 watts, about 6.6 kWh/yr (~$1.06/yr at $0.16/kWh) for 1 hr/day shower timers or 159.4 kWh/yr (~$25.50/yr) continuously. Closest competing matches include Utilitech 7115-01 (100.0 CFM) and ACIQ AES100 (100.0 CFM).

## What attic duct routing preserves Fantech FGC 4 (40420) CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Fantech FGC 4 (40420), preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Fantech FGC 4 (40420) measure up on airflow and noise ratings?

Each row below breaks down Fantech FGC 4 (40420) certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Fantech (52 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FGC 4 (40420) / FG Series | PD ID 2394294 (Qualified 2022-04-01) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (100 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Fantech FGC 4 (40420) CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Fantech FGC 4 (40420)

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 100 sq ft | 1 CFM/sq ft @ 100 CFM |
| Tall Bath (9-ft Ceiling) | Up to 88 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 50 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.6 kWh/yr (~$1.06/yr) | 18.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 159.4 kWh/yr (~$25.50/yr) | 18.2 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Fantech FGC 4 (40420)?

Compare Fantech FGC 4 (40420) side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech 7115-01**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-01/) | 100 / 95.4 CFM | 1.5 sones | 6.5 CFM/W | 4 in. diameter |
| [**ACIQ AES100**](https://siematic-charleston.com/ventilation-fans/aciq-aes100/) | 100 / 90.2 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**CFM TF100N**](https://siematic-charleston.com/ventilation-fans/cfm-tf100n/) | 100 / 90.2 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**S&P PCLP100XP**](https://siematic-charleston.com/ventilation-fans/s-p-pclp100xp/) | 100 / 90.2 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Panasonic Eco Solutions RG-N110LHA**](https://siematic-charleston.com/ventilation-fans/panasonic-eco-solutions-rg-n110lha/) | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |

## Can you size Fantech FGC 4 (40420) for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Fantech FGC 4 (40420) verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Fantech FGC 4 (40420)?

Compare where Fantech FGC 4 (40420) excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 100 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Target comfort around ENERGY STAR sones up to 100 sq ft
- **Suited to:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Fantech FGC 4 (40420)?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Fantech FGC 4 (40420).

### Why might a contractor swap Fantech FGC 4 (40420) for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Fantech FGC 4 (40420) lacks adequate reserve.

### How does Fantech FGC 4 (40420) handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Fantech FGC 4 (40420) yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

### Is Fantech FGC 4 (40420) quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Fantech FGC 4 (40420) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Fantech FGC 4 (40420) energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Fantech FGC 4 (40420) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech FGC 4 (40420)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Fantech FGC 4 (40420)?

Fantech FGC 4 (40420) features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Fantech FGC 4 (40420)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech FGC 4 (40420)'s safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Fantech FGC 4 (40420) serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Fantech FGC 4 (40420) supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

## What neighboring pages and tools support Fantech FGC 4 (40420)?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Fantech FGC 4 (40420).

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Fantech PB110 (40568) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-pb110-40568/)
- [Fantech PB110L10 (44943) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-pb110l10-44943/)
- [Fantech FG 4 (40402) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-fg-4-40402/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)