#  Fantech FGC 8 EC Exhaust Fan Specifications

ENERGY STAR PD #2346866 · In-line (single-port) · Qualified 2019-09-20

Verified Specification Summary

Homeowners specifying Fantech FGC 8 EC gain 380 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output) where it omits a published 0.1-inch sone rating and delivers 5.5 CFM/W efficacy, venting bathrooms up to 380 sq ft cleanly through 8 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech FGC 8 EC Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 380 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 5.5 CFM/W (#471/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 69.1 W (25.2 kWh/yr)

- **Duct & Tier**: 8 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Fantech FGC 8 EC vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech FGC 8 EC (EPA filing PD #2346866) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 380 CFM (#10 of 1,145 certified models) via a 8 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 8 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Fantech maintains 52 active ENERGY STAR blowers; FGC 8 EC (series: FGC 8 EC) (PD #2346866) gained qualification on 2019-09-20. Lighting kit: No. At 5.5 CFM/W (#471 of 1,145, top 42.8% of 1,145 rated models, more efficient than 57.2% of rated models, 0.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 69.1 watts, about 25.2 kWh/yr (~$4.03/yr at $0.16/kWh) for 1 hr/day shower timers or 605.3 kWh/yr (~$96.85/yr) continuously. Closest competing matches include Delta VDBFRS200 (200.0 CFM) and Delta VDBFRS200HT (200.0 CFM).

## Which exterior damper path suits Fantech FGC 8 EC best?

Exterior roof or wall damper termination paired with insulated 8 in. diameter metal pipe prevents condensation buildup around Fantech FGC 8 EC housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Fantech FGC 8 EC acoustic and static metrics stand?

Compare Fantech FGC 8 EC published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Fantech (52 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FGC 8 EC / FGC 8 EC | PD ID 2346866 (Qualified 2019-09-20) |
| **Duct Connection** | 8 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (380 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Fantech FGC 8 EC handle taller ceilings or walk-in tub steam?

Evaluate how Fantech FGC 8 EC scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Fantech FGC 8 EC

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 380 sq ft | 1 CFM/sq ft @ 380 CFM |
| Tall Bath (9-ft Ceiling) | Up to 337 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 330 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 25.2 kWh/yr (~$4.03/yr) | 69.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 605.3 kWh/yr (~$96.85/yr) | 69.1 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Fantech FGC 8 EC?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta VDBFRS200**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200/) | 200 / N/A CFM | Unpublished | 5.3 CFM/W | 6 in. diameter |
| [**Delta VDBFRS200HT**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200ht/) | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| [**Delta VDBFRS200HT-P**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200ht-p/) | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| [**Delta VDB200**](https://siematic-charleston.com/ventilation-fans/delta-vdb200/) | 200 / N/A CFM | Unpublished | 6.6 CFM/W | 6 in. diameter |
| [**Broan FIN-180B**](https://siematic-charleston.com/ventilation-fans/broan-fin-180b/) | 180 / N/A CFM | Unpublished | 6.8 CFM/W | 6 in. diameter |

## Is Fantech FGC 8 EC sized right for your shower or tub room?

Check whether Fantech FGC 8 EC clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Fantech FGC 8 EC?

Compare where Fantech FGC 8 EC excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 330 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Moisture load fits 380 CFM net static output
- **Suited to:** Collar pairs with 8 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Fantech FGC 8 EC?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Fantech FGC 8 EC.

### Is Fantech FGC 8 EC energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Fantech FGC 8 EC pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech FGC 8 EC's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Fantech FGC 8 EC?

Fantech FGC 8 EC features a 8 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Fantech FGC 8 EC's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech FGC 8 EC's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Fantech FGC 8 EC serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Fantech FGC 8 EC supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Fantech FGC 8 EC for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Fantech FGC 8 EC lacks adequate reserve.

### How does Fantech FGC 8 EC handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Fantech FGC 8 EC yields unlisted 0.25 in. w.g. backpressure figures, so smooth 8 in. diameter rigid metal ducting protects real exhaust.

### Is Fantech FGC 8 EC quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Fantech FGC 8 EC produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

## How can you cross-check Fantech FGC 8 EC against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Fantech FGC 8 EC.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Ortech OIF8-560 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ortech-oif8-560/)
- [Fantech FG 6M EC Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-fg-6m-ec/)
- [Fantech FG 8 EC Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-fg-8-ec/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)