#  Fantech FR 150 (411334) Exhaust Fan Specifications

ENERGY STAR PD #2405570 · In-line (single-port) · Qualified 2022-12-09

Verified Specification Summary

Tested under HVI protocols, the Fantech FR 150 (411334) exhaust unit achieves 280 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating and delivers 4.3 CFM/W efficacy, covering standard baths up to 280 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech FR 150 (411334) Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 280 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.3 CFM/W (#718/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 65.1 W (23.8 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Fantech FR 150 (411334) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech FR 150 (411334) (EPA filing PD #2405570) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 280 CFM (#20 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Manufacturer coverage places FR 150 (411334) (series: FR) (PD #2405570) among 52 Fantech entries qualified through 2022-12-09. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 65.1 watts, about 23.8 kWh/yr (~$3.81/yr at $0.16/kWh) for 1 hr/day shower timers or 570.3 kWh/yr (~$91.25/yr) continuously. Closest competing matches include Panasonic FV-30VQ3 (280.0 CFM) and S&P TD-150S (270.0 CFM).

## What attic duct routing preserves Fantech FR 150 (411334) CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Fantech FR 150 (411334), preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Fantech FR 150 (411334) measure up on airflow and noise ratings?

Each row below breaks down Fantech FR 150 (411334) certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Fantech (52 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FR 150 (411334) / FR | PD ID 2405570 (Qualified 2022-12-09) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (280 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Fantech FR 150 (411334) CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Fantech FR 150 (411334)

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 280 sq ft | 1 CFM/sq ft @ 280 CFM |
| Tall Bath (9-ft Ceiling) | Up to 248 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 230 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 23.8 kWh/yr (~$3.81/yr) | 65.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 570.3 kWh/yr (~$91.25/yr) | 65.1 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Fantech FR 150 (411334)?

Compare Fantech FR 150 (411334) side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Panasonic FV-30VQ3**](https://siematic-charleston.com/ventilation-fans/panasonic-fv-30vq3/) | 280 / 254.4 CFM | 2.0 sones | 4.4 CFM/W | 6 in. diameter |
| [**S&P TD-150S**](https://siematic-charleston.com/ventilation-fans/s-p-td-150s/) | 270 / N/A CFM | Unpublished | 4.5 CFM/W | 6 in. diameter |
| [**Broan L250E**](https://siematic-charleston.com/ventilation-fans/broan-l250e/) | 270 / 245 CFM | Unpublished | 4.6 CFM/W | 8 in. diameter |
| [**Broan L300EL**](https://siematic-charleston.com/ventilation-fans/broan-l300el/) | 270 / N/A CFM | Unpublished | 3.9 CFM/W | 8 in. diameter |
| [**S&P TD-150**](https://siematic-charleston.com/ventilation-fans/s-p-td-150/) | 260 / N/A CFM | Unpublished | 4.3 CFM/W | 6 in. diameter |

## Can you size Fantech FR 150 (411334) for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Fantech FR 150 (411334) verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Fantech FR 150 (411334) in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Fantech FR 150 (411334) for residential use.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 280 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Ideal fit:** Target comfort around ENERGY STAR sones up to 280 sq ft
- **Primary match:** Paired with rigid galvanized 6 in. diameter transition

## How do federal and code standards apply to Fantech FR 150 (411334)?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Fantech FR 150 (411334).

### When is Fantech FR 150 (411334) undersized or poorly matched for a bath renovation?

Skip Fantech FR 150 (411334) if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Fantech FR 150 (411334) CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Fantech FR 150 (411334) registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.

### How does Fantech FR 150 (411334) sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Fantech FR 150 (411334) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Fantech FR 150 (411334)?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Fantech FR 150 (411334) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech FR 150 (411334)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Fantech FR 150 (411334)?

Fantech FR 150 (411334) features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Fantech FR 150 (411334)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech FR 150 (411334)'s safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Fantech FR 150 (411334) satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Fantech FR 150 (411334) clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

## What neighboring pages and tools support Fantech FR 150 (411334)?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Fantech FR 150 (411334).

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan L250E Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-l250e/)
- [Broan L300EL Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-l300el/)
- [Ortech ODD-300-3 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ortech-odd-300-3/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)