#  Fantech PB 270-2 (40572) Exhaust Fan Specifications

ENERGY STAR PD #2394297 · In-line (single-port) · Qualified 2022-04-01

Verified Specification Summary

Certified by EPA ENERGY STAR, Fantech PB 270-2 (40572) delivers 260 CFM free-air (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 3.9 CFM/W efficacy, clearing residential IRC M1505 sizing up to 260 sq ft (8-ft height) or 231 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech PB 270-2 (40572) Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 260 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 3.9 CFM/W (#876/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 66.7 W (24.3 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Fantech PB 270-2 (40572) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech PB 270-2 (40572) (EPA filing PD #2394297) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 260 CFM (#28 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Brand catalog footprint: Fantech registers 52 certified models, with SKU PB 270-2 (40572) (series: PB 270 Series) (PD #2394297) certified since 2022-04-01. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 66.7 watts, about 24.3 kWh/yr (~$3.89/yr at $0.16/kWh) for 1 hr/day shower timers or 584.3 kWh/yr (~$93.49/yr) continuously. Closest competing matches include Dayton 5AE72A (240.0 CFM) and Greenheck SP-A200 (240.0 CFM).

## Why does rigid 6 in. diameter ducting protect Fantech PB 270-2 (40572) airflow?

Connecting Fantech PB 270-2 (40572) through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Fantech PB 270-2 (40572) performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Fantech PB 270-2 (40572) lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Fantech (52 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | PB 270-2 (40572) / PB 270 Series | PD ID 2394297 (Qualified 2022-04-01) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (260 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Fantech PB 270-2 (40572)?

Calculated coverage metrics translate Fantech PB 270-2 (40572) airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Fantech PB 270-2 (40572)

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 260 sq ft | 1 CFM/sq ft @ 260 CFM |
| Tall Bath (9-ft Ceiling) | Up to 231 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 210 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 24.3 kWh/yr (~$3.89/yr) | 66.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 584.3 kWh/yr (~$93.49/yr) | 66.7 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Fantech PB 270-2 (40572)?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Dayton 5AE72A**](https://siematic-charleston.com/ventilation-fans/dayton-5ae72a/) | 240 / N/A CFM | 1.4 sones | 4.3 CFM/W | 8 x 8 in. rectangular |
| [**Greenheck SP-A200**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-a200/) | 240 / 224 CFM | 1.4 sones | 4.3 CFM/W | 8 x 8 in. rectangular |
| [**S&P TD-150**](https://siematic-charleston.com/ventilation-fans/s-p-td-150/) | 260 / N/A CFM | Unpublished | 4.3 CFM/W | 6 in. diameter |
| [**Broan L300EL**](https://siematic-charleston.com/ventilation-fans/broan-l300el/) | 270 / N/A CFM | Unpublished | 3.9 CFM/W | 8 in. diameter |
| [**S&P TD-150S**](https://siematic-charleston.com/ventilation-fans/s-p-td-150s/) | 270 / N/A CFM | Unpublished | 4.5 CFM/W | 6 in. diameter |

## Does Fantech PB 270-2 (40572) match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Fantech PB 270-2 (40572) percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Fantech PB 270-2 (40572) in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Fantech PB 270-2 (40572) for residential use.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 210 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Ideal fit:** Moisture load fits 260 CFM net static output
- **Primary match:** Collar pairs with 6 in. diameter duct straight outdoors

## Which homeowner questions come up most for Fantech PB 270-2 (40572)?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Fantech PB 270-2 (40572).

### When is Fantech PB 270-2 (40572) undersized or poorly matched for a bath renovation?

Skip Fantech PB 270-2 (40572) if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Fantech PB 270-2 (40572) CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Fantech PB 270-2 (40572) registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.

### How does Fantech PB 270-2 (40572) sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Fantech PB 270-2 (40572) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define Fantech PB 270-2 (40572)?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Fantech PB 270-2 (40572) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech PB 270-2 (40572)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Fantech PB 270-2 (40572)?

Fantech PB 270-2 (40572) features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Fantech PB 270-2 (40572)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech PB 270-2 (40572)'s safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Fantech PB 270-2 (40572) satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Fantech PB 270-2 (40572) clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

## Where can you explore more benchmarks around Fantech PB 270-2 (40572)?

Use the related reference pages and estimators below to cross-check Fantech PB 270-2 (40572) against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Fantech PB 270L10-2 (44945) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-pb-270l10-2-44945/)
- [Fantech PB 270L10V2 (44947) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-pb-270l10v2-44947/)
- [Fantech FGC 6 (40381) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-fgc-6-40381/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)