title: "Fantech PB 270L7V-2 (44946) Bath Fan (260 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/fantech-pb-270l7v-2-44946/
description: "ENERGY STAR specs for Fantech PB 270L7V-2 (44946): 260 CFM, 3.9 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering."
---

#  Fantech PB 270L7V-2 (44946) Exhaust Fan Specifications

ENERGY STAR PD #2394308 · Bathroom/Utility Room · Qualified 2022-04-01

Verified Specification Summary

In EPA dataset 8dv7-nngq, Fantech PB 270L7V-2 (44946) tests at 260 CFM free discharge (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 3.9 CFM/W efficacy, meeting residential IRC M1505 sizing up to 260 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech PB 270L7V-2 (44946) Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 260 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 3.9 CFM/W (#876/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 66.7 W (24.3 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Fantech PB 270L7V-2 (44946) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech PB 270L7V-2 (44946) (EPA filing PD #2394308) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Free-discharge delivery reaches 260 CFM (#28 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Brand catalog footprint: Fantech registers 52 certified models, with SKU PB 270L7V-2 (44946) (series: PB 270 Series) (PD #2394308) certified since 2022-04-01. Lighting kit: Yes. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 66.7 watts, about 24.3 kWh/yr (~$3.89/yr at $0.16/kWh) for 1 hr/day shower timers or 584.3 kWh/yr (~$93.49/yr) continuously. Closest competing matches include Dayton 5AE72A (240.0 CFM) and Greenheck SP-A200 (240.0 CFM).

## Why avoid unvented attic termination with Fantech PB 270L7V-2 (44946)?

Under ASHRAE 62.2 best practice, Fantech PB 270L7V-2 (44946) needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Fantech PB 270L7V-2 (44946)?

Before cutting ceiling drywall or sizing attic transitions for Fantech PB 270L7V-2 (44946), confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Fantech (52 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | PB 270L7V-2 (44946) / PB 270 Series | PD ID 2394308 (Qualified 2022-04-01) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (260 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What daily runtime and room footprint suit Fantech PB 270L7V-2 (44946)?

Bathroom ventilation sizing below maps Fantech PB 270L7V-2 (44946) motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Fantech PB 270L7V-2 (44946)

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 260 sq ft | 1 CFM/sq ft @ 260 CFM |
| Tall Bath (9-ft Ceiling) | Up to 231 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 210 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 24.3 kWh/yr (~$3.89/yr) | 66.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 584.3 kWh/yr (~$93.49/yr) | 66.7 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Fantech PB 270L7V-2 (44946) in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Fantech PB 270L7V-2 (44946).

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Dayton 5AE72A**](https://siematic-charleston.com/ventilation-fans/dayton-5ae72a/) | 240 / N/A CFM | 1.4 sones | 4.3 CFM/W | 8 x 8 in. rectangular |
| [**Greenheck SP-A200**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-a200/) | 240 / 224 CFM | 1.4 sones | 4.3 CFM/W | 8 x 8 in. rectangular |
| [**S&P TD-150**](https://siematic-charleston.com/ventilation-fans/s-p-td-150/) | 260 / N/A CFM | Unpublished | 4.3 CFM/W | 6 in. diameter |
| [**Broan L300EL**](https://siematic-charleston.com/ventilation-fans/broan-l300el/) | 270 / N/A CFM | Unpublished | 3.9 CFM/W | 8 in. diameter |
| [**S&P TD-150S**](https://siematic-charleston.com/ventilation-fans/s-p-td-150s/) | 270 / N/A CFM | Unpublished | 4.5 CFM/W | 6 in. diameter |

## What percentage of room demand does Fantech PB 270L7V-2 (44946) cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Fantech PB 270L7V-2 (44946) tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Fantech PB 270L7V-2 (44946) fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Fantech PB 270L7V-2 (44946).

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 260 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Recommended when:** Target comfort around ENERGY STAR sones up to 260 sq ft
- **Target scenario:** Paired with rigid galvanized 6 in. diameter transition

## Where do official rules set limits for Fantech PB 270L7V-2 (44946)?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Fantech PB 270L7V-2 (44946).

### Which bathroom layouts should pick a larger blower than Fantech PB 270L7V-2 (44946)?

Do not force Fantech PB 270L7V-2 (44946) into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Fantech PB 270L7V-2 (44946) retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Fantech PB 270L7V-2 (44946) produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.

### Will Fantech PB 270L7V-2 (44946) disturb adjacent bedrooms during night use?

Acoustic measurement places Fantech PB 270L7V-2 (44946) at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running Fantech PB 270L7V-2 (44946) continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Fantech PB 270L7V-2 (44946) draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Fantech PB 270L7V-2 (44946) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech PB 270L7V-2 (44946)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Fantech PB 270L7V-2 (44946)?

Fantech PB 270L7V-2 (44946) features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Fantech PB 270L7V-2 (44946)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech PB 270L7V-2 (44946)'s safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Fantech PB 270L7V-2 (44946) code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Fantech PB 270L7V-2 (44946) clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

## What related resources expand on Fantech PB 270L7V-2 (44946)?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [S&P TD-150 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/s-p-td-150/)
- [Broan L200E Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-l200e/)
- [Fantech PB 270L710-2 (44948) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-pb-270l710-2-44948/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)