#  Fantech PB110 (40568) Exhaust Fan Specifications

ENERGY STAR PD #2393563 · In-line (single-port) · Qualified 2022-03-04

Verified Specification Summary

Homeowners specifying Fantech PB110 (40568) gain 100 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output) where it omits a published 0.1-inch sone rating and delivers 5.5 CFM/W efficacy, venting bathrooms up to 100 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech PB110 (40568) Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / N/A CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 5.5 CFM/W (#471/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 18.2 W (6.6 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Fantech PB110 (40568) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech PB110 (40568) (EPA filing PD #2393563) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 100 CFM (#621 of 1,145 certified models) via a 4 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places PB110 (40568) (series: PB 110 Series) (PD #2393563) among 52 Fantech entries qualified through 2022-03-04. Lighting kit: No. At 5.5 CFM/W (#471 of 1,145, top 42.8% of 1,145 rated models, more efficient than 57.2% of rated models, 0.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.2 watts, about 6.6 kWh/yr (~$1.06/yr at $0.16/kWh) for 1 hr/day shower timers or 159.4 kWh/yr (~$25.50/yr) continuously. Closest competing matches include Utilitech 7115-01 (100.0 CFM) and ACIQ AES100 (100.0 CFM).

## Which exterior damper path suits Fantech PB110 (40568) best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Fantech PB110 (40568) housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Fantech PB110 (40568) acoustic and static metrics stand?

Compare Fantech PB110 (40568) published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Fantech (52 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | PB110 (40568) / PB 110 Series | PD ID 2393563 (Qualified 2022-03-04) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (100 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Fantech PB110 (40568) handle taller ceilings or walk-in tub steam?

Evaluate how Fantech PB110 (40568) scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Fantech PB110 (40568)

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 100 sq ft | 1 CFM/sq ft @ 100 CFM |
| Tall Bath (9-ft Ceiling) | Up to 88 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 50 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.6 kWh/yr (~$1.06/yr) | 18.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 159.4 kWh/yr (~$25.50/yr) | 18.2 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Fantech PB110 (40568)?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech 7115-01**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-01/) | 100 / 95.4 CFM | 1.5 sones | 6.5 CFM/W | 4 in. diameter |
| [**ACIQ AES100**](https://siematic-charleston.com/ventilation-fans/aciq-aes100/) | 100 / 90.2 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**CFM TF100N**](https://siematic-charleston.com/ventilation-fans/cfm-tf100n/) | 100 / 90.2 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**S&P PCLP100XP**](https://siematic-charleston.com/ventilation-fans/s-p-pclp100xp/) | 100 / 90.2 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Panasonic Eco Solutions RG-N110LHA**](https://siematic-charleston.com/ventilation-fans/panasonic-eco-solutions-rg-n110lha/) | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |

## Is Fantech PB110 (40568) sized right for your shower or tub room?

Check whether Fantech PB110 (40568) clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Fantech PB110 (40568)?

Compare where Fantech PB110 (40568) excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 50 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Moisture load fits 100 CFM net static output
- **Suited to:** Collar pairs with 4 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Fantech PB110 (40568)?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Fantech PB110 (40568).

### Is Fantech PB110 (40568) quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Fantech PB110 (40568) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Fantech PB110 (40568) energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Fantech PB110 (40568) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech PB110 (40568)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Fantech PB110 (40568)?

Fantech PB110 (40568) features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Fantech PB110 (40568)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech PB110 (40568)'s safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Fantech PB110 (40568) serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Fantech PB110 (40568) supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Fantech PB110 (40568) for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Fantech PB110 (40568) lacks adequate reserve.

### How does Fantech PB110 (40568) handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Fantech PB110 (40568) yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

## How can you cross-check Fantech PB110 (40568) against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Fantech PB110 (40568).

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Fantech PB110L10 (44943) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-pb110l10-44943/)
- [Fantech PB110L7 (44942) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-pb110l7-44942/)
- [Fantech FGC 4 (40420) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-fgc-4-40420/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)