title: "Fantech S110-130-150 (484315) Bath Fan (150 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/fantech-s110-130-150-484315/
description: "ENERGY STAR specs for Fantech S110-130-150 (484315): 150 CFM, 12.9 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Fantech S110-130-150 (484315) Exhaust Fan Specifications

ENERGY STAR PD #2507831 · Bathroom/Utility Room · Qualified 2023-05-19

Verified Specification Summary

The Fantech S110-130-150 (484315) (bathfan Select) moves 150 CFM at 0.1 in. w.g. (150 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 12.9 CFM/W efficacy, sizing bathrooms up to 150 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech S110-130-150 (484315) Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 150 / 150 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 12.9 CFM/W (#54/1,145)

- **Static Retention**: 100.0% @ 0.25"

- **Motor Draw**: 11.6 W (4.2 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Fantech S110-130-150 (484315) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech S110-130-150 (484315) (EPA filing PD #2507831) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 150 CFM out of 150 CFM (100.0% retention, 12.3 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Fantech's 52-unit lineup, S110-130-150 (484315) (series: bathfan Select) carries PD #2507831 dating to 2023-05-19. Lighting kit: No. At 12.9 CFM/W (#54 of 1,145, top 5.2% of 1,145 rated models, more efficient than 94.8% of rated models, 8.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.6 watts, about 4.2 kWh/yr (~$0.67/yr at $0.16/kWh) for 1 hr/day shower timers or 101.6 kWh/yr (~$16.26/yr) continuously. Closest competing matches include Loren Cook Company GCVF 100 (127.0 CFM) and Panasonic FV-1115VQ1 (150.0 CFM).

## How does duct geometry alter Fantech S110-130-150 (484315) static pressure?

Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Fantech S110-130-150 (484315)?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Fantech S110-130-150 (484315) alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Fantech (52 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | S110-130-150 (484315) / bathfan Select | PD ID 2507831 (Qualified 2023-05-19) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (150 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can Fantech S110-130-150 (484315) ventilate safely?

Sizing outputs below convert Fantech S110-130-150 (484315) tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Fantech S110-130-150 (484315)

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 150 sq ft | 1 CFM/sq ft @ 150 CFM |
| Tall Bath (9-ft Ceiling) | Up to 133 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 100 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.2 kWh/yr (~$0.67/yr) | 11.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 101.6 kWh/yr (~$16.26/yr) | 11.6 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Fantech S110-130-150 (484315) closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Loren Cook Company GCVF 100**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gcvf-100/) | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
| [**Panasonic FV-1115VQ1**](https://siematic-charleston.com/ventilation-fans/panasonic-fv-1115vq1/) | 150 / 154.7 CFM | Unpublished | 12.9 CFM/W | 6 in. diameter |
| [**Panasonic FV-1115VKL3**](https://siematic-charleston.com/ventilation-fans/panasonic-fv-1115vkl3/) | 150 / 152.1 CFM | Unpublished | 12.2 CFM/W | 6 in. diameter |
| [**Panasonic FV-1115VKL3 with FV-VS15VK1**](https://siematic-charleston.com/ventilation-fans/panasonic-fv-1115vkl3-with-fv-vs15vk1/) | 150 / 152.1 CFM | Unpublished | 12.2 CFM/W | 6 in. diameter |
| [**Panasonic FV-1115VK3**](https://siematic-charleston.com/ventilation-fans/panasonic-fv-1115vk3/) | 150 / 158.7 CFM | Unpublished | 13.7 CFM/W | 6 in. diameter |

## Will Fantech S110-130-150 (484315) clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Fantech S110-130-150 (484315) satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Fantech S110-130-150 (484315) suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Fantech S110-130-150 (484315) for your remodel.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 100 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Strong scenario:** Bathroom floor <= 150 sq ft with 8-ft ceilings (133 sq ft at 9-ft height)
- **Best application:** Exterior run uses smooth rigid metal matched to 6 in. diameter

## What key rules and numbers govern Fantech S110-130-150 (484315)?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Fantech S110-130-150 (484315).

### What acoustic sone tier does Fantech S110-130-150 (484315) occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Fantech S110-130-150 (484315) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

### How many kWh per year does Fantech S110-130-150 (484315) add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Fantech S110-130-150 (484315) averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Fantech S110-130-150 (484315) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech S110-130-150 (484315)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Fantech S110-130-150 (484315)?

Fantech S110-130-150 (484315) features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Fantech S110-130-150 (484315)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech S110-130-150 (484315)'s safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Fantech S110-130-150 (484315) pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Fantech S110-130-150 (484315) easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Fantech S110-130-150 (484315) in a bathroom remodel?

Avoid specifying Fantech S110-130-150 (484315) in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Fantech S110-130-150 (484315) airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Fantech S110-130-150 (484315) achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.

## Which guides and calculators connect next to Fantech S110-130-150 (484315)?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Fantech S110-130-150 (484315).

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Fantech S110-130-150L (484316) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-s110-130-150l-484316/)
- [Fantech SC110-130-150H (484317) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-sc110-130-150h-484317/)
- [Delta SMT150D Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-smt150d/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)