Verified Specification Summary

The Fantech SC50-80-110H (494140) (bathfan Select S Series) moves 110 CFM at 0.1 in. w.g. (114.7 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 10.7 CFM/W efficacy, sizing bathrooms up to 114 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech SC50-80-110H (494140) Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 114.7 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 10.7 CFM/W (#144/1,145)

- **Static Retention**: 104.3% @ 0.25"

- **Motor Draw**: 10.3 W (3.8 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Fantech SC50-80-110H (494140) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech SC50-80-110H (494140) (EPA filing PD #3892104) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 114.7 CFM out of 110 CFM (104.3% retention, 16.6 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Fantech maintains 52 active ENERGY STAR blowers; SC50-80-110H (494140) (series: bathfan Select S Series) (PD #3892104) gained qualification on 2024-11-22. Lighting kit: No. At 10.7 CFM/W (#144 of 1,145, top 13.2% of 1,145 rated models, more efficient than 86.8% of rated models, 6.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.3 watts, about 3.8 kWh/yr (~$0.61/yr at $0.16/kWh) for 1 hr/day shower timers or 90.2 kWh/yr (~$14.43/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

## How does duct geometry alter Fantech SC50-80-110H (494140) static pressure?

Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Fantech SC50-80-110H (494140)?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Fantech SC50-80-110H (494140) alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Fantech (52 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SC50-80-110H (494140) / bathfan Select S Series | PD ID 3892104 (Qualified 2024-11-22) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (114.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can Fantech SC50-80-110H (494140) ventilate safely?

Sizing outputs below convert Fantech SC50-80-110H (494140) tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Fantech SC50-80-110H (494140)

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 114 sq ft | 1 CFM/sq ft @ 114.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 101 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 64 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.8 kWh/yr (~$0.61/yr) | 10.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 90.2 kWh/yr (~$14.43/yr) | 10.3 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Fantech SC50-80-110H (494140) closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**DewStop - Breeze Easy BEL110**](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-bel110/) | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| [**Revent RVL110**](https://siematic-charleston.com/ventilation-fans/revent-rvl110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| [**Revent RVLH110**](https://siematic-charleston.com/ventilation-fans/revent-rvlh110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |

## Will Fantech SC50-80-110H (494140) clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Fantech SC50-80-110H (494140) satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Fantech SC50-80-110H (494140)?

Compare where Fantech SC50-80-110H (494140) excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 64 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Bathroom floor <= 114 sq ft with 8-ft ceilings (101 sq ft at 9-ft height)
- **Suited to:** Exterior run uses smooth rigid metal matched to 6 in. diameter

## What key rules and numbers govern Fantech SC50-80-110H (494140)?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Fantech SC50-80-110H (494140).

### Is Fantech SC50-80-110H (494140) energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Fantech SC50-80-110H (494140) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech SC50-80-110H (494140)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Fantech SC50-80-110H (494140)?

Fantech SC50-80-110H (494140) features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Fantech SC50-80-110H (494140)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech SC50-80-110H (494140)'s safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Fantech SC50-80-110H (494140) serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Fantech SC50-80-110H (494140) supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Fantech SC50-80-110H (494140) for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Fantech SC50-80-110H (494140) lacks adequate reserve.

### How does Fantech SC50-80-110H (494140) handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Fantech SC50-80-110H (494140) yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

### Is Fantech SC50-80-110H (494140) quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Fantech SC50-80-110H (494140) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

## Which guides and calculators connect next to Fantech SC50-80-110H (494140)?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Fantech SC50-80-110H (494140).

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Fantech SC50-80-110L (484314) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-sc50-80-110l-484314/)
- [Greenheck SP-AP0511W Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-ap0511w/)
- [Fantech SC50-80-110 (484313) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-sc50-80-110-484313/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)