#  Fantech SC50-80-110L (484314) Exhaust Fan Specifications

ENERGY STAR PD #2507881 · Bathroom/Utility Room · Qualified 2023-05-19

Verified Specification Summary

In EPA dataset 8dv7-nngq, Fantech SC50-80-110L (484314) tests at 110 CFM free discharge (114.7 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 10.7 CFM/W efficacy, meeting residential IRC M1505 sizing up to 114 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech SC50-80-110L (484314) Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 114.7 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 10.7 CFM/W (#144/1,145)

- **Static Retention**: 104.3% @ 0.25"

- **Motor Draw**: 10.3 W (3.8 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Fantech SC50-80-110L (484314) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech SC50-80-110L (484314) (EPA filing PD #2507881) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 114.7 CFM out of 110 CFM (104.3% retention, 16.6 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #2507881 verifies SC50-80-110L (484314) (series: bathfan Select) under Fantech (52 listed models, qualified 2023-05-19). Lighting kit: Yes. At 10.7 CFM/W (#144 of 1,145, top 13.2% of 1,145 rated models, more efficient than 86.8% of rated models, 6.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.3 watts, about 3.8 kWh/yr (~$0.61/yr at $0.16/kWh) for 1 hr/day shower timers or 90.2 kWh/yr (~$14.43/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

## Why avoid unvented attic termination with Fantech SC50-80-110L (484314)?

Under ASHRAE 62.2 best practice, Fantech SC50-80-110L (484314) needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Fantech SC50-80-110L (484314)?

Before cutting ceiling drywall or sizing attic transitions for Fantech SC50-80-110L (484314), confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Fantech (52 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SC50-80-110L (484314) / bathfan Select | PD ID 2507881 (Qualified 2023-05-19) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (114.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What daily runtime and room footprint suit Fantech SC50-80-110L (484314)?

Bathroom ventilation sizing below maps Fantech SC50-80-110L (484314) motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Fantech SC50-80-110L (484314)

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 114 sq ft | 1 CFM/sq ft @ 114.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 101 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 64 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.8 kWh/yr (~$0.61/yr) | 10.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 90.2 kWh/yr (~$14.43/yr) | 10.3 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Fantech SC50-80-110L (484314) in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Fantech SC50-80-110L (484314).

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**DewStop - Breeze Easy BEL110**](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-bel110/) | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| [**Revent RVL110**](https://siematic-charleston.com/ventilation-fans/revent-rvl110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| [**Revent RVLH110**](https://siematic-charleston.com/ventilation-fans/revent-rvlh110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |

## What percentage of room demand does Fantech SC50-80-110L (484314) cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Fantech SC50-80-110L (484314) tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Fantech SC50-80-110L (484314) suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Fantech SC50-80-110L (484314) for your remodel.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 114.7 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Strong scenario:** Target comfort around ENERGY STAR sones up to 114 sq ft
- **Best application:** Paired with rigid galvanized 6 in. diameter transition

## Where do official rules set limits for Fantech SC50-80-110L (484314)?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Fantech SC50-80-110L (484314).

### Does duct resistance cut Fantech SC50-80-110L (484314) airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Fantech SC50-80-110L (484314) achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Fantech SC50-80-110L (484314) occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Fantech SC50-80-110L (484314) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

### How many kWh per year does Fantech SC50-80-110L (484314) add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Fantech SC50-80-110L (484314) averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Fantech SC50-80-110L (484314) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech SC50-80-110L (484314)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Fantech SC50-80-110L (484314)?

Fantech SC50-80-110L (484314) features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Fantech SC50-80-110L (484314)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech SC50-80-110L (484314)'s safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Fantech SC50-80-110L (484314) pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Fantech SC50-80-110L (484314) easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Fantech SC50-80-110L (484314) in a bathroom remodel?

Avoid specifying Fantech SC50-80-110L (484314) in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

## What related resources expand on Fantech SC50-80-110L (484314)?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Greenheck SP-AP0511W Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-ap0511w/)
- [Greenheck SP-AP0511W-1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-ap0511w-1/)
- [Fantech SC50-80-110H (494140) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-sc50-80-110h-494140/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)