title: "Fantech SFC50-80-100HO (484309) Bath Fan (100 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/fantech-sfc50-80-100ho-484309/
description: "ENERGY STAR specs for Fantech SFC50-80-100HO (484309): 100 CFM, 9.3 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Fantech SFC50-80-100HO (484309) Exhaust Fan Specifications

ENERGY STAR PD #2546750 · Bathroom/Utility Room · Qualified 2023-04-28

Verified Specification Summary

Tested under HVI protocols, the Fantech SFC50-80-100HO (484309) exhaust unit achieves 100 CFM at 0.1 in. w.g. (106.5 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 9.3 CFM/W efficacy, covering standard baths up to 106 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech SFC50-80-100HO (484309) Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 106.5 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 9.3 CFM/W (#258/1,145)

- **Static Retention**: 106.5% @ 0.25"

- **Motor Draw**: 10.8 W (3.9 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Fantech SFC50-80-100HO (484309) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech SFC50-80-100HO (484309) (EPA filing PD #2546750) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 106.5 CFM out of 100 CFM (106.5% retention, 18.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Fantech registers 52 certified models, with SKU SFC50-80-100HO (484309) (series: bathfan Select Fit) (PD #2546750) certified since 2023-04-28. Lighting kit: No. At 9.3 CFM/W (#258 of 1,145, top 24.5% of 1,145 rated models, more efficient than 75.5% of rated models, 4.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.8 watts, about 3.9 kWh/yr (~$0.62/yr at $0.16/kWh) for 1 hr/day shower timers or 94.6 kWh/yr (~$15.14/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Delta 100HS (100.0 CFM).

## What attic duct routing preserves Fantech SFC50-80-100HO (484309) CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Fantech SFC50-80-100HO (484309), preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Fantech SFC50-80-100HO (484309) measure up on airflow and noise ratings?

Each row below breaks down Fantech SFC50-80-100HO (484309) certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Fantech (52 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SFC50-80-100HO (484309) / bathfan Select Fit | PD ID 2546750 (Qualified 2023-04-28) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (106.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Fantech SFC50-80-100HO (484309) CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Fantech SFC50-80-100HO (484309)

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 106 sq ft | 1 CFM/sq ft @ 106.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 94 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 56 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.9 kWh/yr (~$0.62/yr) | 10.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 94.6 kWh/yr (~$15.14/yr) | 10.8 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Fantech SFC50-80-100HO (484309)?

Compare Fantech SFC50-80-100HO (484309) side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta GBR100LED-DECOR**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/) | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| [**Delta 100HS**](https://siematic-charleston.com/ventilation-fans/delta-100hs/) | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| [**Delta ITG100ELED**](https://siematic-charleston.com/ventilation-fans/delta-itg100eled/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Delta ITG100RLED**](https://siematic-charleston.com/ventilation-fans/delta-itg100rled/) | 100 / 89.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Utilitech 7115-02**](https://siematic-charleston.com/ventilation-fans/utilitech-7115-02/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## Can you size Fantech SFC50-80-100HO (484309) for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Fantech SFC50-80-100HO (484309) verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Fantech SFC50-80-100HO (484309) fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Fantech SFC50-80-100HO (484309).

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 106.5 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Recommended when:** Target comfort around ENERGY STAR sones up to 106 sq ft
- **Target scenario:** Paired with rigid galvanized 4 in. diameter transition

## How do federal and code standards apply to Fantech SFC50-80-100HO (484309)?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Fantech SFC50-80-100HO (484309).

### Which bathroom layouts should pick a larger blower than Fantech SFC50-80-100HO (484309)?

Do not force Fantech SFC50-80-100HO (484309) into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Fantech SFC50-80-100HO (484309) retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Fantech SFC50-80-100HO (484309) produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

### Will Fantech SFC50-80-100HO (484309) disturb adjacent bedrooms during night use?

Acoustic measurement places Fantech SFC50-80-100HO (484309) at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running Fantech SFC50-80-100HO (484309) continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Fantech SFC50-80-100HO (484309) draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Fantech SFC50-80-100HO (484309) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech SFC50-80-100HO (484309)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Fantech SFC50-80-100HO (484309)?

Fantech SFC50-80-100HO (484309) features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Fantech SFC50-80-100HO (484309)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech SFC50-80-100HO (484309)'s safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Fantech SFC50-80-100HO (484309) code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Fantech SFC50-80-100HO (484309) clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

## What neighboring pages and tools support Fantech SFC50-80-100HO (484309)?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Fantech SFC50-80-100HO (484309).

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Fantech SFC50-80-100L (484310) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-sfc50-80-100l-484310/)
- [Fantech SFC50-80-100LH (484311) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-sfc50-80-100lh-484311/)
- [Fantech SFC50-80-100H (484308) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-sfc50-80-100h-484308/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)