---
title: "Field Controls FAPV-L Bath Fan (138.1 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/field-controls-fapv-l/
description: "ENERGY STAR specs for Field Controls FAPV-L: 138.1 CFM, 5.0 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering."
---

#  Field Controls FAPV-L Exhaust Fan Specifications

ENERGY STAR PD #3892682 · In-line (single-port) · Qualified 2025-01-09

Verified Specification Summary

Tested under HVI protocols, the Field Controls FAPV-L exhaust unit achieves 138.1 CFM at 0.1 in. w.g. (106 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 5.0 CFM/W efficacy, covering standard baths up to 106 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Field Controls FAPV-L Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 138.1 / 106 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 5.0 CFM/W (#514/1,145)

- **Static Retention**: 76.8% @ 0.25"

- **Motor Draw**: 27.6 W (10.1 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Field Controls FAPV-L vs. 1,145-Model ENERGY STAR Benchmarks show?

Field Controls FAPV-L (EPA filing PD #3892682) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Expect noticeable duct drag: airflow moves from 138.1 CFM open-air to 106 CFM at 0.25 in. w.g. (76.8% retention, 10.9 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Field Controls maintains 1 active ENERGY STAR blower; FAPV-L (series: FAPV-L) (PD #3892682) gained qualification on 2025-01-09. Lighting kit: No. At 5.0 CFM/W (#514 of 1,145, top 45.2% of 1,145 rated models, more efficient than 54.8% of rated models, 0.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 27.6 watts, about 10.1 kWh/yr (~$1.62/yr at $0.16/kWh) for 1 hr/day shower timers or 241.8 kWh/yr (~$38.69/yr) continuously. Closest competing matches include Broan QT130E (130.0 CFM) and Broan QT130LE (130.0 CFM).

## What attic duct routing preserves Field Controls FAPV-L CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Field Controls FAPV-L, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Field Controls FAPV-L measure up on airflow and noise ratings?

Each row below breaks down Field Controls FAPV-L certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Field Controls (1 model) | ENERGY STAR Certified Partner |
| **Model Number & Series** | FAPV-L / FAPV-L | PD ID 3892682 (Qualified 2025-01-09) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (106 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Field Controls FAPV-L CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Field Controls FAPV-L

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 106 sq ft | 1 CFM/sq ft @ 106 CFM |
| Tall Bath (9-ft Ceiling) | Up to 94 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 56 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.1 kWh/yr (~$1.62/yr) | 27.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 241.8 kWh/yr (~$38.69/yr) | 27.6 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Field Controls FAPV-L?

Compare Field Controls FAPV-L side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan QT130E**](https://siematic-charleston.com/ventilation-fans/broan-qt130e-4429508/) | 130 / 130.4 CFM | 1.5 sones | 4.7 CFM/W | 6 in. diameter |
| [**Broan QT130LE**](https://siematic-charleston.com/ventilation-fans/broan-qt130le-2404744/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Nutone QTN130LE1**](https://siematic-charleston.com/ventilation-fans/nutone-qtn130le1/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Broan QT150LE**](https://siematic-charleston.com/ventilation-fans/broan-qt150le/) | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Tech Drive TD-BF-24L-5CCT(BL)**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-24l-5cct-bl/) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |

## Can you size Field Controls FAPV-L for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Field Controls FAPV-L verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Field Controls FAPV-L?

Match Field Controls FAPV-L directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 106 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Best for:** Target comfort around ENERGY STAR sones up to 106 sq ft
- **Optimal use:** Paired with rigid galvanized 6 in. diameter transition

## How do federal and code standards apply to Field Controls FAPV-L?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Field Controls FAPV-L.

### What bathroom square footage can Field Controls FAPV-L ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Field Controls FAPV-L covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does Field Controls FAPV-L run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Field Controls FAPV-L.

### What happens to Field Controls FAPV-L CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Field Controls FAPV-L moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.

### Where does Field Controls FAPV-L sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Field Controls FAPV-L produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Field Controls FAPV-L cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Field Controls FAPV-L 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Field Controls FAPV-L pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Field Controls FAPV-L's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Field Controls FAPV-L?

Field Controls FAPV-L features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Field Controls FAPV-L's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Field Controls FAPV-L's safe coverage footprint from 50 sq ft to 44 sq ft.

## What neighboring pages and tools support Field Controls FAPV-L?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Field Controls FAPV-L.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Whirlpool Corporation WVW73UC0LS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/whirlpool-corporation-wvw73uc0ls/)
- [Air King F130D Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-f130d/)
- [GE JVX5305DJBB Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ge-jvx5305djbb/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
