#  Greenheck CSP-A110 Exhaust Fan Specifications

ENERGY STAR PD #2364772 · In-line (single-port) · Qualified 2020-08-10

Verified Specification Summary

Tested under HVI protocols, the Greenheck CSP-A110 exhaust unit achieves 94 CFM at 0.1 in. w.g. (85 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 5.1 CFM/W efficacy, covering standard baths up to 85 sq ft on a 6 x 8 in. rectangular collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck CSP-A110 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 94 / 85 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 5.1 CFM/W (#507/1,145)

- **Static Retention**: 90.4% @ 0.25"

- **Motor Draw**: 18.4 W (6.7 kWh/yr)

- **Duct & Tier**: 6 x 8 in. rectangular · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Greenheck CSP-A110 vs. 1,145-Model ENERGY STAR Benchmarks show?

Greenheck CSP-A110 (EPA filing PD #2364772) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 85 CFM out of 94 CFM (90.4% retention, 2.7 pts higher retention than the 87.7% median). Use a tight rectangular-to-round galvanized transition off the 6 x 8 in. rectangular housing before entering attic bays.

Brand catalog footprint: Greenheck registers 31 certified models, with SKU CSP-A110 (series: CSP) (PD #2364772) certified since 2020-08-10. Lighting kit: No. At 5.1 CFM/W (#507 of 1,145, top 44.8% of 1,145 rated models, more efficient than 55.2% of rated models, 0.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.4 watts, about 6.7 kWh/yr (~$1.07/yr at $0.16/kWh) for 1 hr/day shower timers or 161.2 kWh/yr (~$25.79/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-V80A (90.0 CFM) and Akicon AK1390N2-B (90.0 CFM).

## What attic duct routing preserves Greenheck CSP-A110 CFM output?

Short straight 6 x 8 in. rectangular duct paths retain up to ~82% of open-air capacity on Greenheck CSP-A110, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Greenheck CSP-A110 measure up on airflow and noise ratings?

Each row below breaks down Greenheck CSP-A110 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Greenheck (31 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | CSP-A110 / CSP | PD ID 2364772 (Qualified 2020-08-10) |
| **Duct Connection** | 6 x 8 in. rectangular | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (85 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Greenheck CSP-A110 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Greenheck CSP-A110

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 85 sq ft | 1 CFM/sq ft @ 85 CFM |
| Tall Bath (9-ft Ceiling) | Up to 75 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 35 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.7 kWh/yr (~$1.07/yr) | 18.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 161.2 kWh/yr (~$25.79/yr) | 18.4 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Greenheck CSP-A110?

Compare Greenheck CSP-A110 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Panasonic Eco Solutions RG-V80A**](https://siematic-charleston.com/ventilation-fans/panasonic-eco-solutions-rg-v80a/) | 90 / 79.2 CFM | 1.5 sones | 4.3 CFM/W | 4 in. diameter |
| [**Akicon AK1390N2-B**](https://siematic-charleston.com/ventilation-fans/akicon-ak1390n2-b/) | 90 / 71.7 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Akicon AK1390N2-S**](https://siematic-charleston.com/ventilation-fans/akicon-ak1390n2-s/) | 90 / 71.7 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Akicon AK1390N2-W**](https://siematic-charleston.com/ventilation-fans/akicon-ak1390n2-w/) | 90 / 71.7 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| [**Akicon AK1390N3-W/B/S**](https://siematic-charleston.com/ventilation-fans/akicon-ak1390n3-w-b-s/) | 90 / 71.8 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |

## Can you size Greenheck CSP-A110 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Greenheck CSP-A110 verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Greenheck CSP-A110 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Greenheck CSP-A110.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 85 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Recommended when:** Target comfort around ENERGY STAR sones up to 85 sq ft
- **Target scenario:** Paired with rigid galvanized 6 x 8 in. rectangular transition

## How do federal and code standards apply to Greenheck CSP-A110?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Greenheck CSP-A110.

### How much airflow does Greenheck CSP-A110 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Greenheck CSP-A110 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 x 8 in. rectangular metal duct transitions.

### Will Greenheck CSP-A110 disturb adjacent bedrooms during night use?

Acoustic measurement places Greenheck CSP-A110 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running Greenheck CSP-A110 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Greenheck CSP-A110 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Greenheck CSP-A110 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck CSP-A110's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Greenheck CSP-A110?

Greenheck CSP-A110 features a 6 x 8 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Greenheck CSP-A110's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck CSP-A110's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Greenheck CSP-A110 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Greenheck CSP-A110 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Greenheck CSP-A110?

Do not force Greenheck CSP-A110 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

## What neighboring pages and tools support Greenheck CSP-A110?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Greenheck CSP-A110.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Panasonic Eco Solutions FV-0709VB1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-eco-solutions-fv-0709vb1/)
- [Panasonic FV-0709RM1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/panasonic-fv-0709rm1/)
- [Dayton 3DPE7 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/dayton-3dpe7/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)