title: "Greenheck CSP-A200 Bath Fan (213 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/greenheck-csp-a200/
description: "ENERGY STAR specs for Greenheck CSP-A200: 213 CFM, 3.9 CFM/W, 8 x 6 in. rectangular and 5 closest peer fans. Verified US agency benchmarks, engineering."
---

#  Greenheck CSP-A200 Exhaust Fan Specifications

ENERGY STAR PD #2354803 · In-line (single-port) · Qualified 2020-02-14

Verified Specification Summary

Certified by EPA ENERGY STAR, Greenheck CSP-A200 delivers 213 CFM free-air (204 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 3.9 CFM/W efficacy, clearing residential IRC M1505 sizing up to 204 sq ft (8-ft height) or 181 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck CSP-A200 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 213 / 204 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 3.9 CFM/W (#876/1,145)

- **Static Retention**: 95.8% @ 0.25"

- **Motor Draw**: 54.6 W (19.9 kWh/yr)

- **Duct & Tier**: 8 x 6 in. rectangular · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Greenheck CSP-A200 vs. 1,145-Model ENERGY STAR Benchmarks show?

Greenheck CSP-A200 (EPA filing PD #2354803) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 204 CFM out of 213 CFM (95.8% retention, 8.1 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Manufacturer coverage places CSP-A200 (series: CSP) (PD #2354803) among 31 Greenheck entries qualified through 2020-02-14. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 54.6 watts, about 19.9 kWh/yr (~$3.18/yr at $0.16/kWh) for 1 hr/day shower timers or 478.3 kWh/yr (~$76.53/yr) continuously. Closest competing matches include Dayton 6WZN6 (213.0 CFM) and Broan L150E (210.0 CFM).

## Why does rigid 8 x 6 in. rectangular ducting protect Greenheck CSP-A200 airflow?

Connecting Greenheck CSP-A200 through rigid 8 x 6 in. rectangular steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Greenheck CSP-A200 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Greenheck CSP-A200 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Greenheck (31 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | CSP-A200 / CSP | PD ID 2354803 (Qualified 2020-02-14) |
| **Duct Connection** | 8 x 6 in. rectangular | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (204 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Greenheck CSP-A200?

Calculated coverage metrics translate Greenheck CSP-A200 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Greenheck CSP-A200

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 204 sq ft | 1 CFM/sq ft @ 204 CFM |
| Tall Bath (9-ft Ceiling) | Up to 181 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 154 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 19.9 kWh/yr (~$3.18/yr) | 54.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 478.3 kWh/yr (~$76.53/yr) | 54.6 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Greenheck CSP-A200?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Dayton 6WZN6**](https://siematic-charleston.com/ventilation-fans/dayton-6wzn6/) | 213 / 204 CFM | Unpublished | 3.9 CFM/W | 8 x 8 in. rectangular |
| [**Broan L150E**](https://siematic-charleston.com/ventilation-fans/broan-l150e/) | 210 / 175.2 CFM | Unpublished | 5.0 CFM/W | 8 in. diameter |
| [**Broan L200EL**](https://siematic-charleston.com/ventilation-fans/broan-l200el/) | 200 / N/A CFM | Unpublished | 4.0 CFM/W | 8 in. diameter |
| [**Zephyr ZSI-E30BS-ES**](https://siematic-charleston.com/ventilation-fans/zephyr-zsi-e30bs-es/) | 200 / N/A CFM | Unpublished | 3.5 CFM/W | 8 in. diameter |
| [**Zephyr ZSI-E36BS-ES**](https://siematic-charleston.com/ventilation-fans/zephyr-zsi-e36bs-es/) | 200 / N/A CFM | Unpublished | 3.5 CFM/W | 8 in. diameter |

## Does Greenheck CSP-A200 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Greenheck CSP-A200 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Greenheck CSP-A200 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Greenheck CSP-A200 carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 154 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Choose this if:** Moisture load fits 204 CFM net static output
- **Works well for:** Collar pairs with 8 x 6 in. rectangular duct straight outdoors

## Which homeowner questions come up most for Greenheck CSP-A200?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Greenheck CSP-A200.

### What duct and room conditions disqualify Greenheck CSP-A200?

Rule out Greenheck CSP-A200 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Greenheck CSP-A200 capacity?

Because static drag at 0.25 in. w.g. lowers Greenheck CSP-A200 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 8 x 6 in. rectangular rigid ducting straight to a dedicated exterior damper.

### How loud is Greenheck CSP-A200 compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Greenheck CSP-A200 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Greenheck CSP-A200 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Greenheck CSP-A200 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Greenheck CSP-A200 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck CSP-A200's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Greenheck CSP-A200?

Greenheck CSP-A200 features a 8 x 6 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Greenheck CSP-A200's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck CSP-A200's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Greenheck CSP-A200 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Greenheck CSP-A200 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

## Where can you explore more benchmarks around Greenheck CSP-A200?

Use the related reference pages and estimators below to cross-check Greenheck CSP-A200 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Broan L150E Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-l150e/)
- [Broan L200EL Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-l200el/)
- [Dayton 6WZN6 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/dayton-6wzn6/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)