#  Greenheck CSP-A390-VG Exhaust Fan Specifications

ENERGY STAR PD #2353546 · In-line (single-port) · Qualified 2019-12-10

Verified Specification Summary

Homeowners specifying Greenheck CSP-A390-VG gain 388 CFM at 0.1 in. w.g. (359 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 4.9 CFM/W efficacy, venting bathrooms up to 359 sq ft cleanly through 8 x 8 in. rectangular rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck CSP-A390-VG Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 388 / 359 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 4.9 CFM/W (#519/1,145)

- **Static Retention**: 92.5% @ 0.25"

- **Motor Draw**: 79.2 W (28.9 kWh/yr)

- **Duct & Tier**: 8 x 8 in. rectangular · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Greenheck CSP-A390-VG vs. 1,145-Model ENERGY STAR Benchmarks show?

Greenheck CSP-A390-VG (EPA filing PD #2353546) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 359 CFM out of 388 CFM (92.5% retention, 4.8 pts higher retention than the 87.7% median). Use a tight rectangular-to-round galvanized transition off the 8 x 8 in. rectangular housing before entering attic bays.

Greenheck maintains 31 active ENERGY STAR blowers; CSP-A390-VG (series: CSP) (PD #2353546) gained qualification on 2019-12-10. Lighting kit: No. At 4.9 CFM/W (#519 of 1,145, top 46.6% of 1,145 rated models, more efficient than 53.4% of rated models, 0.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 79.2 watts, about 28.9 kWh/yr (~$4.62/yr at $0.16/kWh) for 1 hr/day shower timers or 693.8 kWh/yr (~$111.01/yr) continuously. Closest competing matches include Delta VDBFRS200HT (200.0 CFM) and Delta VDBFRS200HT-P (200.0 CFM).

## Which exterior damper path suits Greenheck CSP-A390-VG best?

Exterior roof or wall damper termination paired with insulated 8 x 8 in. rectangular metal pipe prevents condensation buildup around Greenheck CSP-A390-VG housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Greenheck CSP-A390-VG acoustic and static metrics stand?

Compare Greenheck CSP-A390-VG published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Greenheck (31 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | CSP-A390-VG / CSP | PD ID 2353546 (Qualified 2019-12-10) |
| **Duct Connection** | 8 x 8 in. rectangular | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (359 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Greenheck CSP-A390-VG handle taller ceilings or walk-in tub steam?

Evaluate how Greenheck CSP-A390-VG scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Greenheck CSP-A390-VG

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 359 sq ft | 1 CFM/sq ft @ 359 CFM |
| Tall Bath (9-ft Ceiling) | Up to 319 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 309 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 28.9 kWh/yr (~$4.62/yr) | 79.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 693.8 kWh/yr (~$111.01/yr) | 79.2 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Greenheck CSP-A390-VG?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta VDBFRS200HT**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200ht/) | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| [**Delta VDBFRS200HT-P**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200ht-p/) | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| [**Delta VDBFRS200**](https://siematic-charleston.com/ventilation-fans/delta-vdbfrs200/) | 200 / N/A CFM | Unpublished | 5.3 CFM/W | 6 in. diameter |
| [**Delta VDB200**](https://siematic-charleston.com/ventilation-fans/delta-vdb200/) | 200 / N/A CFM | Unpublished | 6.6 CFM/W | 6 in. diameter |
| [**Broan FIN-180B**](https://siematic-charleston.com/ventilation-fans/broan-fin-180b/) | 180 / N/A CFM | Unpublished | 6.8 CFM/W | 6 in. diameter |

## Is Greenheck CSP-A390-VG sized right for your shower or tub room?

Check whether Greenheck CSP-A390-VG clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Greenheck CSP-A390-VG?

Compare where Greenheck CSP-A390-VG excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 309 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Moisture load fits 359 CFM net static output
- **Suited to:** Collar pairs with 8 x 8 in. rectangular duct straight outdoors

## Which code checks and cost facts matter for Greenheck CSP-A390-VG?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Greenheck CSP-A390-VG.

### Why might a contractor swap Greenheck CSP-A390-VG for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Greenheck CSP-A390-VG lacks adequate reserve.

### How does Greenheck CSP-A390-VG handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Greenheck CSP-A390-VG yields unlisted 0.25 in. w.g. backpressure figures, so smooth 8 x 8 in. rectangular rigid metal ducting protects real exhaust.

### Is Greenheck CSP-A390-VG quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Greenheck CSP-A390-VG produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Greenheck CSP-A390-VG energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Greenheck CSP-A390-VG pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck CSP-A390-VG's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Greenheck CSP-A390-VG?

Greenheck CSP-A390-VG features a 8 x 8 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Greenheck CSP-A390-VG's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck CSP-A390-VG's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Greenheck CSP-A390-VG serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Greenheck CSP-A390-VG supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

## How can you cross-check Greenheck CSP-A390-VG against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Greenheck CSP-A390-VG.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Fantech FG 8 EC Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-fg-8-ec/)
- [Fantech FGC 8 EC Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-fgc-8-ec/)
- [Fantech FGC 8 (40423) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-fgc-8-40423/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)