#  Greenheck SP-A125 Exhaust Fan Specifications

ENERGY STAR PD #2335073 · Bathroom/Utility Room · Qualified 2015-10-15

Verified Specification Summary

Certified by EPA ENERGY STAR, Greenheck SP-A125 delivers 109 CFM free-air (unpublished 0.25 in. w.g. output) and registers #135 of 607 in quietness (0.7 sones) and delivers 5.8 CFM/W efficacy, clearing residential IRC M1505 sizing up to 109 sq ft (8-ft height) or 96 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-A125 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 109 / N/A CFM

- **Noise @ 0.1"**: 0.7 sones (#135/607)

- **Efficacy Rank**: 5.8 CFM/W (#461/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 18.8 W (6.9 kWh/yr)

- **Duct & Tier**: 6 x 8 in. rectangular · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Greenheck SP-A125 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Free-discharge delivery reaches 109 CFM (#620 of 1,145 certified models) via a 6 x 8 in. rectangular exhaust collar without published 0.25 in. w.g. test points. Use a tight rectangular-to-round galvanized transition off the 6 x 8 in. rectangular housing before entering attic bays.

Greenheck maintains 31 active ENERGY STAR blowers; SP-A125 (series: SP) (PD #2335073) gained qualification on 2015-10-15. Lighting kit: No. At 5.8 CFM/W (#461 of 1,145, top 40.7% of 1,145 rated models, more efficient than 59.3% of rated models, 1.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.8 watts, about 6.9 kWh/yr (~$1.10/yr at $0.16/kWh) for 1 hr/day shower timers or 164.7 kWh/yr (~$26.35/yr) continuously. Closest competing matches include AERO PURE ABF110L5W (110.0 CFM) and AUPU AV11AL1 (110.0 CFM).

## How noisy is Greenheck SP-A125 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Greenheck SP-A125 measures 0.7 sones across the 1,145-model registry.

## Why does rigid 6 x 8 in. rectangular ducting protect Greenheck SP-A125 airflow?

Connecting Greenheck SP-A125 through rigid 6 x 8 in. rectangular steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Greenheck SP-A125 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Greenheck SP-A125 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Greenheck (31 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SP-A125 / SP | PD ID 2335073 (Qualified 2015-10-15) |
| **Duct Connection** | 6 x 8 in. rectangular | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (109 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.7 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Greenheck SP-A125?

Calculated coverage metrics translate Greenheck SP-A125 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Greenheck SP-A125

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 109 sq ft | 1 CFM/sq ft @ 109 CFM |
| Tall Bath (9-ft Ceiling) | Up to 96 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 59 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.9 kWh/yr (~$1.10/yr) | 18.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 164.7 kWh/yr (~$26.35/yr) | 18.8 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Greenheck SP-A125?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**AERO PURE ABF110L5W**](https://siematic-charleston.com/ventilation-fans/aero-pure-abf110l5w/) | 110 / 89 CFM | 0.7 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| [**AUPU AV11AL1**](https://siematic-charleston.com/ventilation-fans/aupu-av11al1/) | 110 / 89 CFM | 0.7 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| [**AUPU AV11AL2**](https://siematic-charleston.com/ventilation-fans/aupu-av11al2/) | 110 / 89 CFM | 0.7 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| [**ACIQ ANP100**](https://siematic-charleston.com/ventilation-fans/aciq-anp100/) | 100 / 97.3 CFM | 0.8 sones (+0.10) | 4.7 CFM/W | 4 in. diameter |
| [**Canarm CNP100**](https://siematic-charleston.com/ventilation-fans/canarm-cnp100/) | 100 / 97.3 CFM | 0.8 sones (+0.10) | 4.7 CFM/W | 4 in. diameter |

## Does Greenheck SP-A125 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Greenheck SP-A125 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Where should contractors skip Greenheck SP-A125 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Greenheck SP-A125 carefully below before approving contractor material schedules.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 59 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Choose this if:** Moisture load fits 109 CFM net static output
- **Works well for:** Collar pairs with 6 x 8 in. rectangular duct straight outdoors

## Which homeowner questions come up most for Greenheck SP-A125?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Greenheck SP-A125.

### What duct and room conditions disqualify Greenheck SP-A125?

Rule out Greenheck SP-A125 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

### Will long attic ducting choke Greenheck SP-A125 capacity?

Because static drag at 0.25 in. w.g. lowers Greenheck SP-A125 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 x 8 in. rectangular rigid ducting straight to a dedicated exterior damper.

### How loud is Greenheck SP-A125 compared with a standard 3.0 sone builder fan?

Tested at 0.7 sones, Greenheck SP-A125 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

### How much power does Greenheck SP-A125 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Greenheck SP-A125 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

### Can Greenheck SP-A125 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-A125's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Greenheck SP-A125?

Greenheck SP-A125 features a 6 x 8 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Greenheck SP-A125's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-A125's safe coverage footprint from 50 sq ft to 44 sq ft.

### How does Greenheck SP-A125 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Greenheck SP-A125 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

## Where can you explore more benchmarks around Greenheck SP-A125?

Use the related reference pages and estimators below to cross-check Greenheck SP-A125 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [KORA SBF90DC-MS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kora-sbf90dc-ms/)
- [Ortech OD-9005PB Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ortech-od-9005pb/)
- [AUPU AV11AL2 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aupu-av11al2/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)