#  Greenheck SP-A200 Exhaust Fan Specifications

ENERGY STAR PD #2335075 · Bathroom/Utility Room · Qualified 2015-10-15

Verified Specification Summary

Rated for 240 CFM open-air (224 CFM at 0.25 in. w.g.), Greenheck SP-A200 registers #405 of 607 in quietness (1.4 sones) and delivers 4.3 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 224 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-A200 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 240 / 224 CFM

- **Noise @ 0.1"**: 1.4 sones (#405/607)

- **Efficacy Rank**: 4.3 CFM/W (#718/1,145)

- **Static Retention**: 93.3% @ 0.25"

- **Motor Draw**: 55.8 W (20.4 kWh/yr)

- **Duct & Tier**: 8 x 8 in. rectangular · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Greenheck SP-A200 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.4 sones (#405 of 607 rated models, 0.40 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 224 CFM out of 240 CFM (93.3% retention, 5.6 pts higher retention than the 87.7% median). Use a tight rectangular-to-round galvanized transition off the 8 x 8 in. rectangular housing before entering attic bays.

Greenheck maintains 31 active ENERGY STAR blowers; SP-A200 (series: SP) (PD #2335075) gained qualification on 2015-10-15. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 55.8 watts, about 20.4 kWh/yr (~$3.26/yr at $0.16/kWh) for 1 hr/day shower timers or 488.8 kWh/yr (~$78.21/yr) continuously. Closest competing matches include Dayton 5AE72A (240.0 CFM) and Broan L200E (240.0 CFM).

## How does Greenheck SP-A200 acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Greenheck SP-A200 (1.4 sones).

## How do flex elbows choke Greenheck SP-A200 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 8 x 8 in. rectangular metal pipe keeps Greenheck SP-A200 moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Greenheck SP-A200 meet residential exhaust fan code specs?

Inspect Greenheck SP-A200 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Greenheck (31 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SP-A200 / SP | PD ID 2335075 (Qualified 2015-10-15) |
| **Duct Connection** | 8 x 8 in. rectangular | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (224 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.4 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Which bathroom duties match Greenheck SP-A200 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Greenheck SP-A200 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Greenheck SP-A200

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 224 sq ft | 1 CFM/sq ft @ 224 CFM |
| Tall Bath (9-ft Ceiling) | Up to 199 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 174 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 20.4 kWh/yr (~$3.26/yr) | 55.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 488.8 kWh/yr (~$78.21/yr) | 55.8 W x 8,760 hrs / 1,000 |

## Which competing models share Greenheck SP-A200 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Dayton 5AE72A**](https://siematic-charleston.com/ventilation-fans/dayton-5ae72a/) | 240 / N/A CFM | 1.4 sones (Same) | 4.3 CFM/W | 8 x 8 in. rectangular |
| [**Broan L200E**](https://siematic-charleston.com/ventilation-fans/broan-l200e/) | 240 / 205.9 CFM | Unpublished | 4.7 CFM/W | 8 in. diameter |
| [**Broan L250EL**](https://siematic-charleston.com/ventilation-fans/broan-l250el/) | 230 / N/A CFM | Unpublished | 3.9 CFM/W | 8 in. diameter |
| [**S&P TD-150**](https://siematic-charleston.com/ventilation-fans/s-p-td-150/) | 260 / N/A CFM | Unpublished | 4.3 CFM/W | 6 in. diameter |
| [**Fantech FG 6 (40406)**](https://siematic-charleston.com/ventilation-fans/fantech-fg-6-40406/) | 260 / N/A CFM | Unpublished | 3.9 CFM/W | 6 in. diameter |

## How much airflow margin does Greenheck SP-A200 give your bath?

Run a quick local room-volume check for Greenheck SP-A200 by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Greenheck SP-A200?

Compare where Greenheck SP-A200 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 174 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Bathroom floor <= 224 sq ft with 8-ft ceilings (199 sq ft at 9-ft height)
- **Suited to:** Exterior run uses smooth rigid metal matched to 8 x 8 in. rectangular

## What should homeowners verify first about Greenheck SP-A200?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Greenheck SP-A200.

### Is Greenheck SP-A200 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Greenheck SP-A200 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-A200's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Greenheck SP-A200?

Greenheck SP-A200 features a 8 x 8 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Greenheck SP-A200's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-A200's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Greenheck SP-A200 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Greenheck SP-A200 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Greenheck SP-A200 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Greenheck SP-A200 lacks adequate reserve.

### How does Greenheck SP-A200 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Greenheck SP-A200 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 8 x 8 in. rectangular rigid metal ducting protects real exhaust.

### Is Greenheck SP-A200 quiet enough for a primary bedroom bathroom?

At 1.4 sones, Greenheck SP-A200 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

## Which GradeMark tools pair best with Greenheck SP-A200?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Greenheck SP-A200.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Utilitech UTLDR110 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/)
- [Utilitech UTLDS110 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/)
- [Dayton 5AE72A Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/dayton-5ae72a/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)