title: "Greenheck SP-A250 Bath Fan (270 CFM, 2.2 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/greenheck-sp-a250/
description: "ENERGY STAR specs for Greenheck SP-A250: 270 CFM, 2.2 sones (#604 of 607), 4.3 CFM/W, 8 x 8 in. rectangular and 5 closest peer fans."
---

#  Greenheck SP-A250 Exhaust Fan Specifications

ENERGY STAR PD #2335076 · Bathroom/Utility Room · Qualified 2015-10-15

Verified Specification Summary

Homeowners specifying Greenheck SP-A250 gain 270 CFM at 0.1 in. w.g. (250 CFM at 0.25 in. w.g.) where it registers #604 of 607 in quietness (2.2 sones) and delivers 4.3 CFM/W efficacy, venting bathrooms up to 250 sq ft cleanly through 8 x 8 in. rectangular rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-A250 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 270 / 250 CFM

- **Noise @ 0.1"**: 2.2 sones (#604/607)

- **Efficacy Rank**: 4.3 CFM/W (#718/1,145)

- **Static Retention**: 92.6% @ 0.25"

- **Motor Draw**: 62.8 W (22.9 kWh/yr)

- **Duct & Tier**: 8 x 8 in. rectangular · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Greenheck SP-A250 vs. 1,145-Model ENERGY STAR Benchmarks show?

Utility-grade 2.2 sones acoustic output (#604 of 607 rated models, 1.20 sones louder than the 1.00 sones median), best reserved for powder rooms or laundry alcoves.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 250 CFM out of 270 CFM (92.6% retention, 4.9 pts higher retention than the 87.7% median). Use a tight rectangular-to-round galvanized transition off the 8 x 8 in. rectangular housing before entering attic bays.

Greenheck maintains 31 active ENERGY STAR blowers; SP-A250 (series: SP) (PD #2335076) gained qualification on 2015-10-15. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 62.8 watts, about 22.9 kWh/yr (~$3.66/yr at $0.16/kWh) for 1 hr/day shower timers or 550.1 kWh/yr (~$88.02/yr) continuously. Closest competing matches include Dayton 3DPE6A (270.0 CFM) and S&P TD-150S (270.0 CFM).

## What acoustic percentile does Greenheck SP-A250 occupy among 1,145 bath blowers?

Inspect how Greenheck SP-A250 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

## Which exterior damper path suits Greenheck SP-A250 best?

Exterior roof or wall damper termination paired with insulated 8 x 8 in. rectangular metal pipe prevents condensation buildup around Greenheck SP-A250 housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Greenheck SP-A250 acoustic and static metrics stand?

Compare Greenheck SP-A250 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Greenheck (31 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SP-A250 / SP | PD ID 2335076 (Qualified 2015-10-15) |
| **Duct Connection** | 8 x 8 in. rectangular | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (250 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (2.2 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Greenheck SP-A250 handle taller ceilings or walk-in tub steam?

Evaluate how Greenheck SP-A250 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Greenheck SP-A250

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 250 sq ft | 1 CFM/sq ft @ 250 CFM |
| Tall Bath (9-ft Ceiling) | Up to 222 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 200 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 22.9 kWh/yr (~$3.66/yr) | 62.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 550.1 kWh/yr (~$88.02/yr) | 62.8 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Greenheck SP-A250?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Dayton 3DPE6A**](https://siematic-charleston.com/ventilation-fans/dayton-3dpe6a/) | 270 / N/A CFM | 2.2 sones (Same) | 4.3 CFM/W | 8 x 8 in. rectangular |
| [**S&P TD-150S**](https://siematic-charleston.com/ventilation-fans/s-p-td-150s/) | 270 / N/A CFM | Unpublished | 4.5 CFM/W | 6 in. diameter |
| [**Broan L250E**](https://siematic-charleston.com/ventilation-fans/broan-l250e/) | 270 / 245 CFM | Unpublished | 4.6 CFM/W | 8 in. diameter |
| [**Broan L300EL**](https://siematic-charleston.com/ventilation-fans/broan-l300el/) | 270 / N/A CFM | Unpublished | 3.9 CFM/W | 8 in. diameter |
| [**Fantech FR 150 (411334)**](https://siematic-charleston.com/ventilation-fans/fantech-fr-150-411334/) | 280 / N/A CFM | Unpublished | 4.3 CFM/W | 6 in. diameter |

## Is Greenheck SP-A250 sized right for your shower or tub room?

Check whether Greenheck SP-A250 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Greenheck SP-A250 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Greenheck SP-A250.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 200 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Recommended when:** Moisture load fits 250 CFM net static output
- **Target scenario:** Collar pairs with 8 x 8 in. rectangular duct straight outdoors

## Which code checks and cost facts matter for Greenheck SP-A250?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Greenheck SP-A250.

### Does running Greenheck SP-A250 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Greenheck SP-A250 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Greenheck SP-A250 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-A250's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Greenheck SP-A250?

Greenheck SP-A250 features a 8 x 8 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Greenheck SP-A250's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-A250's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Greenheck SP-A250 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Greenheck SP-A250 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Greenheck SP-A250?

Do not force Greenheck SP-A250 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Greenheck SP-A250 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Greenheck SP-A250 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 8 x 8 in. rectangular metal duct transitions.

### Will Greenheck SP-A250 disturb adjacent bedrooms during night use?

Acoustic measurement places Greenheck SP-A250 at 2.2 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

## How can you cross-check Greenheck SP-A250 against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Greenheck SP-A250.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Dayton 5AE71 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/dayton-5ae71/)
- [Air King AK280LS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/air-king-ak280ls/)
- [Dayton 3DPE6A Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/dayton-3dpe6a/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)