title: "Greenheck SP-A70 Bath Fan (70 CFM, 0.1 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/greenheck-sp-a70/
description: "ENERGY STAR specs for Greenheck SP-A70: 70 CFM, 0.1 sones (#10 of 607), 5.1 CFM/W, 6 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Greenheck SP-A70 Exhaust Fan Specifications

ENERGY STAR PD #2335043 · Bathroom/Utility Room · Qualified 2015-10-15

Verified Specification Summary

The Greenheck SP-A70 (SP) moves 70 CFM at 0.1 in. w.g. (54 CFM at 0.25 in. w.g.), registers #10 of 607 in quietness (0.1 sones), and delivers 5.1 CFM/W efficacy, sizing bathrooms up to 54 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-A70 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 70 / 54 CFM

- **Noise @ 0.1"**: 0.1 sones (#10/607)

- **Efficacy Rank**: 5.1 CFM/W (#507/1,145)

- **Static Retention**: 77.1% @ 0.25"

- **Motor Draw**: 13.7 W (5.0 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Greenheck SP-A70 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.1 sones (#10 of 607 rated models, quietest 2.8% of 607 rated models, quieter than 97.2% of rated models, 0.90 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 70 CFM open-air to 54 CFM at 0.25 in. w.g. (77.1% retention, 10.6 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Greenheck maintains 31 active ENERGY STAR blowers; SP-A70 (series: SP) (PD #2335043) gained qualification on 2015-10-15. Lighting kit: No. At 5.1 CFM/W (#507 of 1,145, top 44.8% of 1,145 rated models, more efficient than 55.2% of rated models, 0.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.7 watts, about 5.0 kWh/yr (~$0.80/yr at $0.16/kWh) for 1 hr/day shower timers or 120.0 kWh/yr (~$19.20/yr) continuously. Closest competing matches include Cyclone CBP80 (80.0 CFM) and Ortech ODC-8003 (80.0 CFM).

## Where does Greenheck SP-A70 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.1 sones against all 1,145 EPA listings.

## How does duct geometry alter Greenheck SP-A70 static pressure?

Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Greenheck SP-A70?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Greenheck SP-A70 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Greenheck (31 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SP-A70 / SP | PD ID 2335043 (Qualified 2015-10-15) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (54 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.1 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can Greenheck SP-A70 ventilate safely?

Sizing outputs below convert Greenheck SP-A70 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Greenheck SP-A70

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 54 sq ft | 1 CFM/sq ft @ 54 CFM |
| Tall Bath (9-ft Ceiling) | Up to 48 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.0 kWh/yr (~$0.80/yr) | 13.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 120.0 kWh/yr (~$19.20/yr) | 13.7 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Greenheck SP-A70 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Cyclone CBP80**](https://siematic-charleston.com/ventilation-fans/cyclone-cbp80/) | 80 / 62.6 CFM | 0.2 sones (+0.10) | 4.9 CFM/W | 4 in. diameter |
| [**Ortech ODC-8003**](https://siematic-charleston.com/ventilation-fans/ortech-odc-8003/) | 80 / 62.6 CFM | 0.2 sones (+0.10) | 4.9 CFM/W | 4 in. diameter |
| [**QuFresh BC80**](https://siematic-charleston.com/ventilation-fans/qufresh-bc80/) | 80 / 62.6 CFM | 0.2 sones (+0.10) | 4.9 CFM/W | 4 in. diameter |
| [**Tech Drive TD-BF-06**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-06/) | 70 / 60.4 CFM | 0.3 sones (+0.20) | 4.6 CFM/W | 4 in. diameter |
| [**Win Air BPT14-13E**](https://siematic-charleston.com/ventilation-fans/win-air-bpt14-13e/) | 70 / 60.4 CFM | 0.3 sones (+0.20) | 4.6 CFM/W | 4 in. diameter |

## Will Greenheck SP-A70 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Greenheck SP-A70 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Greenheck SP-A70 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Greenheck SP-A70.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Recommended when:** Bathroom floor <= 54 sq ft with 8-ft ceilings (48 sq ft at 9-ft height)
- **Target scenario:** Exterior run uses smooth rigid metal matched to 6 in. diameter

## What key rules and numbers govern Greenheck SP-A70?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Greenheck SP-A70.

### Which bathroom layouts should pick a larger blower than Greenheck SP-A70?

Do not force Greenheck SP-A70 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Greenheck SP-A70 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Greenheck SP-A70 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.

### Will Greenheck SP-A70 disturb adjacent bedrooms during night use?

Acoustic measurement places Greenheck SP-A70 at 0.1 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

### Does running Greenheck SP-A70 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Greenheck SP-A70 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Greenheck SP-A70 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-A70's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Greenheck SP-A70?

Greenheck SP-A70 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Greenheck SP-A70's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-A70's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Greenheck SP-A70 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Greenheck SP-A70 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

## Which guides and calculators connect next to Greenheck SP-A70?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Greenheck SP-A70.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Cyclone CBP80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/cyclone-cbp80/)
- [Ortech ODC-8003 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ortech-odc-8003/)
- [Broan XB80=XB00HwithXB80F Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-xb80-xb00hwithxb80f/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)