#  Greenheck SP-AP0511W-1 Exhaust Fan Specifications

ENERGY STAR PD #2406840 · Bathroom/Utility Room · Qualified 2023-01-13

Verified Specification Summary

In EPA dataset 8dv7-nngq, Greenheck SP-AP0511W-1 tests at 110 CFM free discharge (128.3 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 10.4 CFM/W efficacy, meeting residential IRC M1505 sizing up to 128 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-AP0511W-1 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 128.3 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 10.4 CFM/W (#171/1,145)

- **Static Retention**: 116.6% @ 0.25"

- **Motor Draw**: 10.6 W (3.9 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Greenheck SP-AP0511W-1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Greenheck SP-AP0511W-1 (EPA filing PD #2406840) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 128.3 CFM out of 110 CFM (116.6% retention, 28.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Greenheck's 31-unit lineup, SP-AP0511W-1 (series: Model SP Ceiling Fan, Direct Drive) carries PD #2406840 dating to 2023-01-13. Lighting kit: No. At 10.4 CFM/W (#171 of 1,145, top 15.2% of 1,145 rated models, more efficient than 84.8% of rated models, 5.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.6 watts, about 3.9 kWh/yr (~$0.62/yr at $0.16/kWh) for 1 hr/day shower timers or 92.9 kWh/yr (~$14.86/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

## Why avoid unvented attic termination with Greenheck SP-AP0511W-1?

Under ASHRAE 62.2 best practice, Greenheck SP-AP0511W-1 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Greenheck SP-AP0511W-1?

Before cutting ceiling drywall or sizing attic transitions for Greenheck SP-AP0511W-1, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Greenheck (31 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SP-AP0511W-1 / Model SP Ceiling Fan, Direct Drive | PD ID 2406840 (Qualified 2023-01-13) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (128.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit Greenheck SP-AP0511W-1?

Bathroom ventilation sizing below maps Greenheck SP-AP0511W-1 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Greenheck SP-AP0511W-1

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 128 sq ft | 1 CFM/sq ft @ 128.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 114 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 78 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.9 kWh/yr (~$0.62/yr) | 10.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 92.9 kWh/yr (~$14.86/yr) | 10.6 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Greenheck SP-AP0511W-1 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Greenheck SP-AP0511W-1.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**Delta GBR100LED-DECOR**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/) | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| [**DewStop - Breeze Easy BEL110**](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-bel110/) | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| [**Revent RVL110**](https://siematic-charleston.com/ventilation-fans/revent-rvl110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |

## What percentage of room demand does Greenheck SP-AP0511W-1 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Greenheck SP-AP0511W-1 tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does Greenheck SP-AP0511W-1 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Greenheck SP-AP0511W-1 for your remodel.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 128.3 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Strong scenario:** Target comfort around ENERGY STAR sones up to 128 sq ft
- **Best application:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for Greenheck SP-AP0511W-1?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Greenheck SP-AP0511W-1.

### How many kWh per year does Greenheck SP-AP0511W-1 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Greenheck SP-AP0511W-1 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can Greenheck SP-AP0511W-1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-AP0511W-1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Greenheck SP-AP0511W-1?

Greenheck SP-AP0511W-1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Greenheck SP-AP0511W-1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-AP0511W-1's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Greenheck SP-AP0511W-1 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Greenheck SP-AP0511W-1 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install Greenheck SP-AP0511W-1 in a bathroom remodel?

Avoid specifying Greenheck SP-AP0511W-1 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut Greenheck SP-AP0511W-1 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Greenheck SP-AP0511W-1 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does Greenheck SP-AP0511W-1 occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Greenheck SP-AP0511W-1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

## What related resources expand on Greenheck SP-AP0511W-1?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Greenheck SP-AP0511W Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-ap0511w-2405572/)
- [Greenheck SP-AP0511WL Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-ap0511wl/)
- [Greenheck SP-AP0511W-1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-ap0511w-1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)