#  Greenheck SP-AP0511W Exhaust Fan Specifications

ENERGY STAR PD #2405571 · Bathroom/Utility Room · Qualified 2022-12-09

Verified Specification Summary

Certified by EPA ENERGY STAR, Greenheck SP-AP0511W delivers 110 CFM free-air (126.1 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 11.8 CFM/W efficacy, clearing residential IRC M1505 sizing up to 126 sq ft (8-ft height) or 112 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-AP0511W Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 126.1 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 11.8 CFM/W (#90/1,145)

- **Static Retention**: 114.6% @ 0.25"

- **Motor Draw**: 9.3 W (3.4 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Greenheck SP-AP0511W vs. 1,145-Model ENERGY STAR Benchmarks show?

Greenheck SP-AP0511W (EPA filing PD #2405571) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 126.1 CFM out of 110 CFM (114.6% retention, 26.9 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Brand catalog footprint: Greenheck registers 31 certified models, with SKU SP-AP0511W (series: Model SP Ceiling Fan, Direct Drive) (PD #2405571) certified since 2022-12-09. Lighting kit: No. At 11.8 CFM/W (#90 of 1,145, top 8.9% of 1,145 rated models, more efficient than 91.1% of rated models, 7.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.3 watts, about 3.4 kWh/yr (~$0.54/yr at $0.16/kWh) for 1 hr/day shower timers or 81.5 kWh/yr (~$13.04/yr) continuously. Closest competing matches include Revent RVL110 (110.0 CFM) and Revent RVLH110 (110.0 CFM).

## Why does rigid 6 in. diameter ducting protect Greenheck SP-AP0511W airflow?

Connecting Greenheck SP-AP0511W through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Greenheck SP-AP0511W performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Greenheck SP-AP0511W lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Greenheck (31 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SP-AP0511W / Model SP Ceiling Fan, Direct Drive | PD ID 2405571 (Qualified 2022-12-09) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (126.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Greenheck SP-AP0511W?

Calculated coverage metrics translate Greenheck SP-AP0511W airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Greenheck SP-AP0511W

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 126 sq ft | 1 CFM/sq ft @ 126.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 112 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 76 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.4 kWh/yr (~$0.54/yr) | 9.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 81.5 kWh/yr (~$13.04/yr) | 9.3 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Greenheck SP-AP0511W?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Revent RVL110**](https://siematic-charleston.com/ventilation-fans/revent-rvl110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| [**Revent RVLH110**](https://siematic-charleston.com/ventilation-fans/revent-rvlh110/) | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| [**DewStop - Breeze Easy BEL110**](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-bel110/) | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Loren Cook Company GCVF 100**](https://siematic-charleston.com/ventilation-fans/loren-cook-company-gcvf-100/) | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |

## Does Greenheck SP-AP0511W match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Greenheck SP-AP0511W percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Greenheck SP-AP0511W fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Greenheck SP-AP0511W.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 76 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Recommended when:** Moisture load fits 126.1 CFM net static output
- **Target scenario:** Collar pairs with 6 in. diameter duct straight outdoors

## Which homeowner questions come up most for Greenheck SP-AP0511W?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Greenheck SP-AP0511W.

### Is Greenheck SP-AP0511W code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Greenheck SP-AP0511W clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Greenheck SP-AP0511W?

Do not force Greenheck SP-AP0511W into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Greenheck SP-AP0511W retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Greenheck SP-AP0511W produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.

### Will Greenheck SP-AP0511W disturb adjacent bedrooms during night use?

Acoustic measurement places Greenheck SP-AP0511W at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running Greenheck SP-AP0511W continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Greenheck SP-AP0511W draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Greenheck SP-AP0511W pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-AP0511W's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Greenheck SP-AP0511W?

Greenheck SP-AP0511W features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Greenheck SP-AP0511W's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-AP0511W's safe coverage footprint from 50 sq ft to 44 sq ft.

## Where can you explore more benchmarks around Greenheck SP-AP0511W?

Use the related reference pages and estimators below to cross-check Greenheck SP-AP0511W against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Greenheck SP-AP0511W-1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-ap0511w-1/)
- [Greenheck SP-AP0511W-1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-ap0511w-1-2406840/)
- [Fantech SC50-80-110L (484314) Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/fantech-sc50-80-110l-484314/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)