#  Greenheck SP-B50 Exhaust Fan Specifications

ENERGY STAR PD #2364769 · Bathroom/Utility Room · Qualified 2020-08-10

Verified Specification Summary

Certified by EPA ENERGY STAR, Greenheck SP-B50 delivers 63 CFM free-air (unpublished 0.25 in. w.g. output) and registers #50 of 607 in quietness (0.4 sones) and delivers 4.0 CFM/W efficacy, clearing residential IRC M1505 sizing up to 63 sq ft (8-ft height) or 56 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-B50 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 63 / N/A CFM

- **Noise @ 0.1"**: 0.4 sones (#50/607)

- **Efficacy Rank**: 4.0 CFM/W (#847/1,145)

- **Static Retention**: 0.1" test only

- **Motor Draw**: 15.8 W (5.8 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Greenheck SP-B50 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Free-discharge delivery reaches 63 CFM (#1,060 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Greenheck's 31-unit lineup, SP-B50 (series: SP) carries PD #2364769 dating to 2020-08-10. Lighting kit: No. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 15.8 watts, about 5.8 kWh/yr (~$0.93/yr at $0.16/kWh) for 1 hr/day shower timers or 138.4 kWh/yr (~$22.14/yr) continuously. Closest competing matches include Dayton 3DPE2 (63.0 CFM) and Tech Drive TD-BF-06-plus (60.0 CFM).

## How noisy is Greenheck SP-B50 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Greenheck SP-B50 measures 0.4 sones across the 1,145-model registry.

## Why does rigid 6 in. diameter ducting protect Greenheck SP-B50 airflow?

Connecting Greenheck SP-B50 through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Greenheck SP-B50 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Greenheck SP-B50 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Greenheck (31 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SP-B50 / SP | PD ID 2364769 (Qualified 2020-08-10) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (63 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.4 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What room sizes and annual power draw fit Greenheck SP-B50?

Calculated coverage metrics translate Greenheck SP-B50 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Greenheck SP-B50

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 63 sq ft | 1 CFM/sq ft @ 63 CFM |
| Tall Bath (9-ft Ceiling) | Up to 56 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.8 kWh/yr (~$0.93/yr) | 15.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 138.4 kWh/yr (~$22.14/yr) | 15.8 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Greenheck SP-B50?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Dayton 3DPE2**](https://siematic-charleston.com/ventilation-fans/dayton-3dpe2/) | 63 / N/A CFM | 0.4 sones (Same) | 4.0 CFM/W | 6 in. diameter |
| [**Tech Drive TD-BF-06-plus**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-06-plus/) | 60 / 51.5 CFM | 0.3 sones (-0.10) | 3.7 CFM/W | 4 in. diameter |
| [**Dayton 1UBH6B**](https://siematic-charleston.com/ventilation-fans/dayton-1ubh6b/) | 70 / N/A CFM | 0.5 sones (+0.10) | 4.4 CFM/W | 6 in. diameter |
| [**Tech Drive TD-BF-06**](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-06/) | 70 / 60.4 CFM | 0.3 sones (-0.10) | 4.6 CFM/W | 4 in. diameter |
| [**Win Air BPT14-13E**](https://siematic-charleston.com/ventilation-fans/win-air-bpt14-13e/) | 70 / 60.4 CFM | 0.3 sones (-0.10) | 4.6 CFM/W | 4 in. diameter |

## Does Greenheck SP-B50 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Greenheck SP-B50 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Greenheck SP-B50?

Compare where Greenheck SP-B50 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Moisture load fits 63 CFM net static output
- **Suited to:** Collar pairs with 6 in. diameter duct straight outdoors

## Which homeowner questions come up most for Greenheck SP-B50?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Greenheck SP-B50.

### Is Greenheck SP-B50 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Greenheck SP-B50 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-B50's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Greenheck SP-B50?

Greenheck SP-B50 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Greenheck SP-B50's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-B50's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Greenheck SP-B50 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Greenheck SP-B50 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Greenheck SP-B50 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Greenheck SP-B50 lacks adequate reserve.

### How does Greenheck SP-B50 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Greenheck SP-B50 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

### Is Greenheck SP-B50 quiet enough for a primary bedroom bathroom?

At 0.4 sones, Greenheck SP-B50 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

## Where can you explore more benchmarks around Greenheck SP-B50?

Use the related reference pages and estimators below to cross-check Greenheck SP-B50 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [ACIQ ANP50 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aciq-anp50/)
- [ACIQ AP50 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/aciq-ap50/)
- [Dayton 3DPE2 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/dayton-3dpe2/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)