---
title: "Greenheck SP-LP0511 Bath Fan (110 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/greenheck-sp-lp0511/
description: "ENERGY STAR specs for Greenheck SP-LP0511: 110 CFM, 9.5 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes."
---

#  Greenheck SP-LP0511 Exhaust Fan Specifications

ENERGY STAR PD #4511652 · Bathroom/Utility Room · Qualified 2025-10-03

Verified Specification Summary

Homeowners specifying Greenheck SP-LP0511 gain 110 CFM at 0.1 in. w.g. (121.1 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 9.5 CFM/W efficacy, venting bathrooms up to 121 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-LP0511 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 121.1 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 9.5 CFM/W (#234/1,145)

- **Static Retention**: 110.1% @ 0.25"

- **Motor Draw**: 11.6 W (4.2 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Greenheck SP-LP0511 vs. 1,145-Model ENERGY STAR Benchmarks show?

Greenheck SP-LP0511 (EPA filing PD #4511652) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 121.1 CFM out of 110 CFM (110.1% retention, 22.4 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places SP-LP0511 (series: Model SP Ceiling Fan, Direct Drive) (PD #4511652) among 31 Greenheck entries qualified through 2025-10-03. Lighting kit: No. At 9.5 CFM/W (#234 of 1,145, top 22.1% of 1,145 rated models, more efficient than 77.9% of rated models, 4.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.6 watts, about 4.2 kWh/yr (~$0.67/yr at $0.16/kWh) for 1 hr/day shower timers or 101.6 kWh/yr (~$16.26/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

## Which exterior damper path suits Greenheck SP-LP0511 best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Greenheck SP-LP0511 housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Greenheck SP-LP0511 acoustic and static metrics stand?

Compare Greenheck SP-LP0511 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Greenheck (31 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SP-LP0511 / Model SP Ceiling Fan, Direct Drive | PD ID 4511652 (Qualified 2025-10-03) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (121.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Greenheck SP-LP0511 handle taller ceilings or walk-in tub steam?

Evaluate how Greenheck SP-LP0511 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Greenheck SP-LP0511

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 121 sq ft | 1 CFM/sq ft @ 121.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 107 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 71 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.2 kWh/yr (~$0.67/yr) | 11.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 101.6 kWh/yr (~$16.26/yr) | 11.6 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Greenheck SP-LP0511?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**Delta GBR100LED-DECOR**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/) | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| [**Delta 100HS**](https://siematic-charleston.com/ventilation-fans/delta-100hs/) | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| [**Delta ITG100ELED**](https://siematic-charleston.com/ventilation-fans/delta-itg100eled/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## Is Greenheck SP-LP0511 sized right for your shower or tub room?

Check whether Greenheck SP-LP0511 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install Greenheck SP-LP0511 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Greenheck SP-LP0511 for residential use.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 71 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Ideal fit:** Moisture load fits 121.1 CFM net static output
- **Primary match:** Collar pairs with 4 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Greenheck SP-LP0511?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Greenheck SP-LP0511.

### What electrical efficiency and runtime kWh define Greenheck SP-LP0511?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can Greenheck SP-LP0511 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-LP0511's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Greenheck SP-LP0511?

Greenheck SP-LP0511 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Greenheck SP-LP0511's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-LP0511's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does Greenheck SP-LP0511 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Greenheck SP-LP0511 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is Greenheck SP-LP0511 undersized or poorly matched for a bath renovation?

Skip Greenheck SP-LP0511 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

### Why check Greenheck SP-LP0511 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Greenheck SP-LP0511 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

### How does Greenheck SP-LP0511 sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Greenheck SP-LP0511 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

## How can you cross-check Greenheck SP-LP0511 against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Greenheck SP-LP0511.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Greenheck SP-LP0511-1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-lp0511-1/)
- [Greenheck SP-LP0511H Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-lp0511h/)
- [Greenheck SP-AP0511WL Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-ap0511wl-4667655/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
