Verified Specification Summary

Homeowners specifying Greenheck SP-LP0511H gain 110 CFM at 0.1 in. w.g. (121.1 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 9.5 CFM/W efficacy, venting bathrooms up to 121 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-LP0511H Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 121.1 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 9.5 CFM/W (#234/1,145)

- **Static Retention**: 110.1% @ 0.25"

- **Motor Draw**: 11.6 W (4.2 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Greenheck SP-LP0511H vs. 1,145-Model ENERGY STAR Benchmarks show?

Greenheck SP-LP0511H (EPA filing PD #4511651) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 121.1 CFM out of 110 CFM (110.1% retention, 22.4 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Greenheck SP-LP0511H (series: Model SP Ceiling Fan, Direct Drive) under PD #4511651 (31 models registered, 2025-10-03). Lighting kit: No. At 9.5 CFM/W (#234 of 1,145, top 22.1% of 1,145 rated models, more efficient than 77.9% of rated models, 4.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.6 watts, about 4.2 kWh/yr (~$0.67/yr at $0.16/kWh) for 1 hr/day shower timers or 101.6 kWh/yr (~$16.26/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

## Which exterior damper path suits Greenheck SP-LP0511H best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Greenheck SP-LP0511H housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do Greenheck SP-LP0511H acoustic and static metrics stand?

Compare Greenheck SP-LP0511H published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Greenheck (31 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SP-LP0511H / Model SP Ceiling Fan, Direct Drive | PD ID 4511651 (Qualified 2025-10-03) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (121.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can Greenheck SP-LP0511H handle taller ceilings or walk-in tub steam?

Evaluate how Greenheck SP-LP0511H scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Greenheck SP-LP0511H

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 121 sq ft | 1 CFM/sq ft @ 121.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 107 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 71 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.2 kWh/yr (~$0.67/yr) | 11.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 101.6 kWh/yr (~$16.26/yr) | 11.6 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near Greenheck SP-LP0511H?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**Delta GBR100LED-DECOR**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/) | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| [**Delta 100HS**](https://siematic-charleston.com/ventilation-fans/delta-100hs/) | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| [**Delta ITG100ELED**](https://siematic-charleston.com/ventilation-fans/delta-itg100eled/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## Is Greenheck SP-LP0511H sized right for your shower or tub room?

Check whether Greenheck SP-LP0511H clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Greenheck SP-LP0511H fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Greenheck SP-LP0511H.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 71 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Recommended when:** Moisture load fits 121.1 CFM net static output
- **Target scenario:** Collar pairs with 4 in. diameter duct straight outdoors

## Which code checks and cost facts matter for Greenheck SP-LP0511H?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Greenheck SP-LP0511H.

### Is Greenheck SP-LP0511H code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Greenheck SP-LP0511H clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Greenheck SP-LP0511H?

Do not force Greenheck SP-LP0511H into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Greenheck SP-LP0511H retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Greenheck SP-LP0511H produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

### Will Greenheck SP-LP0511H disturb adjacent bedrooms during night use?

Acoustic measurement places Greenheck SP-LP0511H at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

### Does running Greenheck SP-LP0511H continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Greenheck SP-LP0511H draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Greenheck SP-LP0511H pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-LP0511H's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Greenheck SP-LP0511H?

Greenheck SP-LP0511H features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Greenheck SP-LP0511H's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-LP0511H's safe coverage footprint from 50 sq ft to 44 sq ft.

## How can you cross-check Greenheck SP-LP0511H against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for Greenheck SP-LP0511H.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Greenheck SP-LP0511HL Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-lp0511hl/)
- [Greenheck SP-LP0511L Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-lp0511l/)
- [Greenheck SP-LP0511-1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-lp0511-1/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)