title: "Greenheck SP-LP0511L Bath Fan (110 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/greenheck-sp-lp0511l/
description: "ENERGY STAR specs for Greenheck SP-LP0511L: 110 CFM, 8.3 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes."
---

#  Greenheck SP-LP0511L Exhaust Fan Specifications

ENERGY STAR PD #4517844 · Bathroom/Utility Room · Qualified 2025-12-05

Verified Specification Summary

The Greenheck SP-LP0511L (Model SP Ceiling Fan, Direct Drive) moves 110 CFM at 0.1 in. w.g. (117.7 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 8.3 CFM/W efficacy, sizing bathrooms up to 117 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-LP0511L Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 117.7 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 8.3 CFM/W (#321/1,145)

- **Static Retention**: 107.0% @ 0.25"

- **Motor Draw**: 13.3 W (4.9 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Greenheck SP-LP0511L vs. 1,145-Model ENERGY STAR Benchmarks show?

Greenheck SP-LP0511L (EPA filing PD #4517844) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 117.7 CFM out of 110 CFM (107.0% retention, 19.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Greenheck's 31-unit lineup, SP-LP0511L (series: Model SP Ceiling Fan, Direct Drive) carries PD #4517844 dating to 2025-12-05. Lighting kit: Yes. At 8.3 CFM/W (#321 of 1,145, top 28.7% of 1,145 rated models, more efficient than 71.3% of rated models, 3.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.3 watts, about 4.9 kWh/yr (~$0.78/yr at $0.16/kWh) for 1 hr/day shower timers or 116.5 kWh/yr (~$18.64/yr) continuously. Closest competing matches include Utilitech UTLDS110 (110.0 CFM) and Delta GBR100LED-DECOR (100.0 CFM).

## How does duct geometry alter Greenheck SP-LP0511L static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to Greenheck SP-LP0511L?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Greenheck SP-LP0511L alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Greenheck (31 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SP-LP0511L / Model SP Ceiling Fan, Direct Drive | PD ID 4517844 (Qualified 2025-12-05) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (117.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How much bathroom area can Greenheck SP-LP0511L ventilate safely?

Sizing outputs below convert Greenheck SP-LP0511L tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Greenheck SP-LP0511L

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 117 sq ft | 1 CFM/sq ft @ 117.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 104 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 67 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.9 kWh/yr (~$0.78/yr) | 13.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 116.5 kWh/yr (~$18.64/yr) | 13.3 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match Greenheck SP-LP0511L closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**Delta GBR100LED-DECOR**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/) | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Delta ITG100ELED**](https://siematic-charleston.com/ventilation-fans/delta-itg100eled/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| [**Delta ITG100RLED**](https://siematic-charleston.com/ventilation-fans/delta-itg100rled/) | 100 / 89.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## Will Greenheck SP-LP0511L clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Greenheck SP-LP0511L satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Greenheck SP-LP0511L?

Match Greenheck SP-LP0511L directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 67 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Best for:** Bathroom floor <= 117 sq ft with 8-ft ceilings (104 sq ft at 9-ft height)
- **Optimal use:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern Greenheck SP-LP0511L?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Greenheck SP-LP0511L.

### What does Greenheck SP-LP0511L cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Greenheck SP-LP0511L 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Greenheck SP-LP0511L pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-LP0511L's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Greenheck SP-LP0511L?

Greenheck SP-LP0511L features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Greenheck SP-LP0511L's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-LP0511L's safe coverage footprint from 50 sq ft to 44 sq ft.

### What bathroom square footage can Greenheck SP-LP0511L ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Greenheck SP-LP0511L covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does Greenheck SP-LP0511L run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Greenheck SP-LP0511L.

### What happens to Greenheck SP-LP0511L CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Greenheck SP-LP0511L moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

### Where does Greenheck SP-LP0511L sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Greenheck SP-LP0511L produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

## Which guides and calculators connect next to Greenheck SP-LP0511L?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for Greenheck SP-LP0511L.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Greenheck SP-LP0511L-1 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-lp0511l-1/)
- [Nutone PEN811 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/nutone-pen811/)
- [Greenheck SP-LP0511HL Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-lp0511hl/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)