---
title: "Greenheck SP-LP0810WL Bath Fan (100 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/greenheck-sp-lp0810wl/
description: "ENERGY STAR specs for Greenheck SP-LP0810WL: 100 CFM, 9.5 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering."
---

#  Greenheck SP-LP0810WL Exhaust Fan Specifications

ENERGY STAR PD #2856281 · Bathroom/Utility Room · Qualified 2023-12-15

Verified Specification Summary

Rated for 100 CFM open-air (106.9 CFM at 0.25 in. w.g.), Greenheck SP-LP0810WL omits a published 0.1-inch sone rating and delivers 9.5 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 106 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-LP0810WL Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 106.9 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 9.5 CFM/W (#234/1,145)

- **Static Retention**: 106.9% @ 0.25"

- **Motor Draw**: 10.5 W (3.8 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Greenheck SP-LP0810WL vs. 1,145-Model ENERGY STAR Benchmarks show?

Greenheck SP-LP0810WL (EPA filing PD #2856281) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 106.9 CFM out of 100 CFM (106.9% retention, 19.2 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Greenheck maintains 31 active ENERGY STAR blowers; SP-LP0810WL (series: Model SP Ceiling Fan, Direct Drive) (PD #2856281) gained qualification on 2023-12-15. Lighting kit: Yes. At 9.5 CFM/W (#234 of 1,145, top 22.1% of 1,145 rated models, more efficient than 77.9% of rated models, 4.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.5 watts, about 3.8 kWh/yr (~$0.61/yr at $0.16/kWh) for 1 hr/day shower timers or 92.0 kWh/yr (~$14.72/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Utilitech UTLDR110 (110.0 CFM).

## How do flex elbows choke Greenheck SP-LP0810WL at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Greenheck SP-LP0810WL moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Greenheck SP-LP0810WL meet residential exhaust fan code specs?

Inspect Greenheck SP-LP0810WL mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Greenheck (31 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SP-LP0810WL / Model SP Ceiling Fan, Direct Drive | PD ID 2856281 (Qualified 2023-12-15) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (106.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## Which bathroom duties match Greenheck SP-LP0810WL airflow output?

Annual electricity figures and room square-footage ceilings below reflect Greenheck SP-LP0810WL tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Greenheck SP-LP0810WL

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 106 sq ft | 1 CFM/sq ft @ 106.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 95 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 56 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.8 kWh/yr (~$0.61/yr) | 10.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 92.0 kWh/yr (~$14.72/yr) | 10.5 W x 8,760 hrs / 1,000 |

## Which competing models share Greenheck SP-LP0810WL airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Delta GBR100LED-DECOR**](https://siematic-charleston.com/ventilation-fans/delta-gbr100led-decor/) | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| [**Utilitech UTLDR110**](https://siematic-charleston.com/ventilation-fans/utilitech-utldr110/) | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| [**Delta 100HS**](https://siematic-charleston.com/ventilation-fans/delta-100hs/) | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| [**Utilitech UTLDS110**](https://siematic-charleston.com/ventilation-fans/utilitech-utlds110/) | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| [**Delta ITG100ELED**](https://siematic-charleston.com/ventilation-fans/delta-itg100eled/) | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |

## How much airflow margin does Greenheck SP-LP0810WL give your bath?

Run a quick local room-volume check for Greenheck SP-LP0810WL by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying Greenheck SP-LP0810WL?

Match Greenheck SP-LP0810WL directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 56 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Best for:** Bathroom floor <= 106 sq ft with 8-ft ceilings (95 sq ft at 9-ft height)
- **Optimal use:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What should homeowners verify first about Greenheck SP-LP0810WL?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Greenheck SP-LP0810WL.

### What bathroom square footage can Greenheck SP-LP0810WL ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Greenheck SP-LP0810WL covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does Greenheck SP-LP0810WL run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Greenheck SP-LP0810WL.

### What happens to Greenheck SP-LP0810WL CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Greenheck SP-LP0810WL moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

### Where does Greenheck SP-LP0810WL sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Greenheck SP-LP0810WL produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does Greenheck SP-LP0810WL cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Greenheck SP-LP0810WL 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can Greenheck SP-LP0810WL pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-LP0810WL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Greenheck SP-LP0810WL?

Greenheck SP-LP0810WL features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Greenheck SP-LP0810WL's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-LP0810WL's safe coverage footprint from 50 sq ft to 44 sq ft.

## Which GradeMark tools pair best with Greenheck SP-LP0810WL?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Greenheck SP-LP0810WL.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Ortech ODDSS-100-3 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ortech-oddss-100-3/)
- [Ortech ODDSS-100-3HS Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ortech-oddss-100-3hs/)
- [Greenheck SP-LP0810W Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/greenheck-sp-lp0810w/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
