title: "Hampton Bay 7114-02 Bath Fan (50 CFM, 1.0 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/hampton-bay-7114-02/
description: "ENERGY STAR specs for Hampton Bay 7114-02: 50 CFM, 1.0 sones (#265 of 607), 10.2 CFM/W, 3 in. diameter and 5 closest peer fans."
---

#  Hampton Bay 7114-02 Exhaust Fan Specifications

ENERGY STAR PD #2589712 · Bathroom/Utility Room · Qualified 2023-06-09

Verified Specification Summary

In EPA dataset 8dv7-nngq, Hampton Bay 7114-02 tests at 50 CFM free discharge (36.9 CFM at 0.25 in. w.g.) and registers #265 of 607 in quietness (1.0 sones) and delivers 10.2 CFM/W efficacy, meeting residential IRC M1505 sizing up to 36 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Hampton Bay 7114-02 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 50 / 36.9 CFM

- **Noise @ 0.1"**: 1.0 sones (#265/607)

- **Efficacy Rank**: 10.2 CFM/W (#179/1,145)

- **Static Retention**: 73.8% @ 0.25"

- **Motor Draw**: 4.9 W (1.8 kWh/yr)

- **Duct & Tier**: 3 in. diameter · Most Eff.

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Hampton Bay 7114-02 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 50 CFM open-air to 36.9 CFM at 0.25 in. w.g. (73.8% retention, 13.9 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Hampton Bay maintains 4 active ENERGY STAR blowers; 7114-02 (series: 7114-02) (PD #2589712) gained qualification on 2023-06-09. Lighting kit: No. At 10.2 CFM/W (#179 of 1,145, top 16.2% of 1,145 rated models, more efficient than 83.8% of rated models, 5.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 4.9 watts, about 1.8 kWh/yr (~$0.29/yr at $0.16/kWh) for 1 hr/day shower timers or 42.9 kWh/yr (~$6.86/yr) continuously. Closest competing matches include HomeWerks Worldwide 7114-02-HW (50.0 CFM) and Utilitech 7114-02-L (50.0 CFM).

## Does Hampton Bay 7114-02 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Hampton Bay 7114-02 at 1.0 sones.

## Why avoid unvented attic termination with Hampton Bay 7114-02?

Under ASHRAE 62.2 best practice, Hampton Bay 7114-02 needs insulated 3 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern Hampton Bay 7114-02?

Before cutting ceiling drywall or sizing attic transitions for Hampton Bay 7114-02, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Hampton Bay (4 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 7114-02 / 7114-02 | PD ID 2589712 (Qualified 2023-06-09) |
| **Duct Connection** | 3 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | CONTINUOUS ONLY (36.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (1.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## What daily runtime and room footprint suit Hampton Bay 7114-02?

Bathroom ventilation sizing below maps Hampton Bay 7114-02 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Hampton Bay 7114-02

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 36 sq ft | 1 CFM/sq ft @ 36.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 32 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 1.8 kWh/yr (~$0.29/yr) | 4.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 42.9 kWh/yr (~$6.86/yr) | 4.9 W x 8,760 hrs / 1,000 |

## What peer models sit nearest Hampton Bay 7114-02 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Hampton Bay 7114-02.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**HomeWerks Worldwide 7114-02-HW**](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7114-02-hw/) | 50 / 36.9 CFM | 1.0 sones (Same) | 10.2 CFM/W | 3 in. diameter |
| [**Utilitech 7114-02-L**](https://siematic-charleston.com/ventilation-fans/utilitech-7114-02-l/) | 50 / 36.9 CFM | 1.0 sones (Same) | 10.2 CFM/W | 3 in. diameter |
| [**Revent RVS50**](https://siematic-charleston.com/ventilation-fans/revent-rvs50/) | 50 / 50 CFM | 1.0 sones (Same) | 9.1 CFM/W | 4 in. diameter |
| [**Revent RVSH50**](https://siematic-charleston.com/ventilation-fans/revent-rvsh50/) | 50 / 50 CFM | 1.0 sones (Same) | 9.1 CFM/W | 4 in. diameter |
| [**Delta 50F**](https://siematic-charleston.com/ventilation-fans/delta-50f/) | 50 / 41.3 CFM | 1.0 sones (Same) | 11.6 CFM/W | 3 in. diameter |

## What percentage of room demand does Hampton Bay 7114-02 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Hampton Bay 7114-02 tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Hampton Bay 7114-02 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Hampton Bay 7114-02.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 36.9 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Recommended when:** Target comfort around 1.0 sones up to 36 sq ft
- **Target scenario:** Paired with rigid galvanized 3 in. diameter transition

## Where do official rules set limits for Hampton Bay 7114-02?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Hampton Bay 7114-02.

### How much airflow does Hampton Bay 7114-02 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Hampton Bay 7114-02 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 3 in. diameter metal duct transitions.

### Will Hampton Bay 7114-02 disturb adjacent bedrooms during night use?

Acoustic measurement places Hampton Bay 7114-02 at 1.0 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

### Does running Hampton Bay 7114-02 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Hampton Bay 7114-02 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Hampton Bay 7114-02 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Hampton Bay 7114-02's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Hampton Bay 7114-02?

Hampton Bay 7114-02 features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Hampton Bay 7114-02's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Hampton Bay 7114-02's safe coverage footprint from 50 sq ft to 44 sq ft.

### Is Hampton Bay 7114-02 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Hampton Bay 7114-02 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Hampton Bay 7114-02?

Do not force Hampton Bay 7114-02 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

## What related resources expand on Hampton Bay 7114-02?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [HomeWerks Worldwide 7114-02-HW Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7114-02-hw/)
- [Utilitech 7114-02-L Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/utilitech-7114-02-l/)
- [Delta SLM50 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-slm50/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)