#  HomeWerks Worldwide 7105-10 Exhaust Fan Specifications

ENERGY STAR PD #2400223 · Bathroom/Utility Room · Qualified 2022-08-12

Verified Specification Summary

The HomeWerks Worldwide 7105-10 (7105-10) moves 70 CFM at 0.1 in. w.g. (55.7 CFM at 0.25 in. w.g.), registers #265 of 607 in quietness (1.0 sones), and delivers 3.4 CFM/W efficacy, sizing bathrooms up to 55 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside HomeWerks Worldwide 7105-10 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 70 / 55.7 CFM

- **Noise @ 0.1"**: 1.0 sones (#265/607)

- **Efficacy Rank**: 3.4 CFM/W (#1,060/1,145)

- **Static Retention**: 79.6% @ 0.25"

- **Motor Draw**: 20.6 W (7.5 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does HomeWerks Worldwide 7105-10 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 70 CFM open-air to 55.7 CFM at 0.25 in. w.g. (79.6% retention, 8.1 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2400223 verifies 7105-10 (series: 7105-10) under HomeWerks Worldwide (31 listed models, qualified 2022-08-12). Lighting kit: Yes. At 3.4 CFM/W (#1,060 of 1,145, below median tier among 1,145 rated models; more efficient than 6.0% of rated models, 1.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.6 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 180.5 kWh/yr (~$28.88/yr) continuously. Closest competing matches include Nektra 33003851 (70.0 CFM) and Tuscany 7105-11-M (70.0 CFM).

## Where does HomeWerks Worldwide 7105-10 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.0 sones against all 1,145 EPA listings.

## How does duct geometry alter HomeWerks Worldwide 7105-10 static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to HomeWerks Worldwide 7105-10?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for HomeWerks Worldwide 7105-10 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | HomeWerks Worldwide (31 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 7105-10 / 7105-10 | PD ID 2400223 (Qualified 2022-08-12) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (55.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (1.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## How much bathroom area can HomeWerks Worldwide 7105-10 ventilate safely?

Sizing outputs below convert HomeWerks Worldwide 7105-10 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for HomeWerks Worldwide 7105-10

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 55 sq ft | 1 CFM/sq ft @ 55.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 49 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.5 kWh/yr (~$1.20/yr) | 20.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 180.5 kWh/yr (~$28.88/yr) | 20.6 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match HomeWerks Worldwide 7105-10 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Nektra 33003851**](https://siematic-charleston.com/ventilation-fans/nektra-33003851/) | 70 / 55.7 CFM | 1.0 sones (Same) | 3.4 CFM/W | 4 in. diameter |
| [**Tuscany 7105-11-M**](https://siematic-charleston.com/ventilation-fans/tuscany-7105-11-m/) | 70 / 55.7 CFM | 1.0 sones (Same) | 3.4 CFM/W | 4 in. diameter |
| [**Broan EZ80**](https://siematic-charleston.com/ventilation-fans/broan-ez80/) | 70 / 60.5 CFM | 1.1 sones (+0.10) | 3.4 CFM/W | 3 in. diameter |
| [**Broan LP80**](https://siematic-charleston.com/ventilation-fans/broan-lp80/) | 70 / 60.5 CFM | 1.1 sones (+0.10) | 3.4 CFM/W | 3 in. diameter |
| [**Broan LP80=LP80HwithLP80F**](https://siematic-charleston.com/ventilation-fans/broan-lp80-lp80hwithlp80f/) | 70 / 60.5 CFM | 1.1 sones (+0.10) | 3.4 CFM/W | 3 in. diameter |

## Will HomeWerks Worldwide 7105-10 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether HomeWerks Worldwide 7105-10 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Which bath layouts should avoid specifying HomeWerks Worldwide 7105-10?

Match HomeWerks Worldwide 7105-10 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

### Limitations & Who Should Skip

- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Best for:** Bathroom floor <= 55 sq ft with 8-ft ceilings (49 sq ft at 9-ft height)
- **Optimal use:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern HomeWerks Worldwide 7105-10?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting HomeWerks Worldwide 7105-10.

### What bathroom square footage can HomeWerks Worldwide 7105-10 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), HomeWerks Worldwide 7105-10 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

### Where does HomeWerks Worldwide 7105-10 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with HomeWerks Worldwide 7105-10.

### What happens to HomeWerks Worldwide 7105-10 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, HomeWerks Worldwide 7105-10 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

### Where does HomeWerks Worldwide 7105-10 sit on acoustic comfort for senior homeowners?

Measuring 1.0 sones, HomeWerks Worldwide 7105-10 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

### What does HomeWerks Worldwide 7105-10 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running HomeWerks Worldwide 7105-10 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

### Can HomeWerks Worldwide 7105-10 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from HomeWerks Worldwide 7105-10's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing HomeWerks Worldwide 7105-10?

HomeWerks Worldwide 7105-10 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change HomeWerks Worldwide 7105-10's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing HomeWerks Worldwide 7105-10's safe coverage footprint from 50 sq ft to 44 sq ft.

## Which guides and calculators connect next to HomeWerks Worldwide 7105-10?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for HomeWerks Worldwide 7105-10.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [HomeWerks Worldwide 7105-10-MB Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7105-10-mb/)
- [Nektra 33003851 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/nektra-33003851/)
- [Utilitech 7141-80-L Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/utilitech-7141-80-l/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)