#  HomeWerks Worldwide 7140-110-G3 Exhaust Fan Specifications

ENERGY STAR PD #2400708 · Bathroom/Utility Room · Qualified 2022-08-26

Verified Specification Summary

The HomeWerks Worldwide 7140-110-G3 (7140-110-G3) moves 110 CFM at 0.1 in. w.g. (95.3 CFM at 0.25 in. w.g.), registers #522 of 607 in quietness (2.0 sones), and delivers 4.5 CFM/W efficacy, sizing bathrooms up to 95 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside HomeWerks Worldwide 7140-110-G3 Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 95.3 CFM

- **Noise @ 0.1"**: 2.0 sones (#522/607)

- **Efficacy Rank**: 4.5 CFM/W (#632/1,145)

- **Static Retention**: 86.6% @ 0.25"

- **Motor Draw**: 24.4 W (8.9 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does HomeWerks Worldwide 7140-110-G3 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 95.3 CFM out of 110 CFM (86.6% retention, 1.1 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places 7140-110-G3 (series: 7140-110-G3) (PD #2400708) among 31 HomeWerks Worldwide entries qualified through 2022-08-26. Lighting kit: No. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 24.4 watts, about 8.9 kWh/yr (~$1.42/yr at $0.16/kWh) for 1 hr/day shower timers or 213.7 kWh/yr (~$34.19/yr) continuously. Closest competing matches include Air King E80S (110.0 CFM) and Air King E80SH (110.0 CFM).

## Where does HomeWerks Worldwide 7140-110-G3 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 2.0 sones against all 1,145 EPA listings.

## How does duct geometry alter HomeWerks Worldwide 7140-110-G3 static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Which certified test ratings apply to HomeWerks Worldwide 7140-110-G3?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for HomeWerks Worldwide 7140-110-G3 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | HomeWerks Worldwide (31 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 7140-110-G3 / 7140-110-G3 | PD ID 2400708 (Qualified 2022-08-26) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (95.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (2.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How much bathroom area can HomeWerks Worldwide 7140-110-G3 ventilate safely?

Sizing outputs below convert HomeWerks Worldwide 7140-110-G3 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for HomeWerks Worldwide 7140-110-G3

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 95 sq ft | 1 CFM/sq ft @ 95.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 84 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 45 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.9 kWh/yr (~$1.42/yr) | 24.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 213.7 kWh/yr (~$34.19/yr) | 24.4 W x 8,760 hrs / 1,000 |

## Which ENERGY STAR fans match HomeWerks Worldwide 7140-110-G3 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Air King E80S**](https://siematic-charleston.com/ventilation-fans/air-king-e80s/) | 110 / 115.9 CFM | Unpublished | 4.5 CFM/W | 6 in. diameter |
| [**Air King E80SH**](https://siematic-charleston.com/ventilation-fans/air-king-e80sh/) | 110 / 115.9 CFM | Unpublished | 4.5 CFM/W | 6 in. diameter |
| [**Win Air BPT14-24A-2**](https://siematic-charleston.com/ventilation-fans/win-air-bpt14-24a-2/) | 110 / 100.4 CFM | Unpublished | 4.5 CFM/W | 4 in. diameter |
| [**Commercial Electric BF1107**](https://siematic-charleston.com/ventilation-fans/commercial-electric-bf1107/) | 110 / 88.6 CFM | Unpublished | 4.3 CFM/W | 4 in. diameter |
| [**Akicon AK13110N4-B**](https://siematic-charleston.com/ventilation-fans/akicon-ak13110n4-b/) | 110 / 87.4 CFM | 2.0 sones (Same) | 4.2 CFM/W | 4 in. diameter |

## Will HomeWerks Worldwide 7140-110-G3 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether HomeWerks Worldwide 7140-110-G3 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Who should not install HomeWerks Worldwide 7140-110-G3 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting HomeWerks Worldwide 7140-110-G3 for residential use.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 45 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Ideal fit:** Bathroom floor <= 95 sq ft with 8-ft ceilings (84 sq ft at 9-ft height)
- **Primary match:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What key rules and numbers govern HomeWerks Worldwide 7140-110-G3?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting HomeWerks Worldwide 7140-110-G3.

### Why check HomeWerks Worldwide 7140-110-G3 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, HomeWerks Worldwide 7140-110-G3 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

### How does HomeWerks Worldwide 7140-110-G3 sound output compare to noisy contractor-grade fans?

Rated at 2.0 sones, HomeWerks Worldwide 7140-110-G3 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

### What electrical efficiency and runtime kWh define HomeWerks Worldwide 7140-110-G3?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

### Can HomeWerks Worldwide 7140-110-G3 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from HomeWerks Worldwide 7140-110-G3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing HomeWerks Worldwide 7140-110-G3?

HomeWerks Worldwide 7140-110-G3 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change HomeWerks Worldwide 7140-110-G3's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing HomeWerks Worldwide 7140-110-G3's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does HomeWerks Worldwide 7140-110-G3 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), HomeWerks Worldwide 7140-110-G3 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

### When is HomeWerks Worldwide 7140-110-G3 undersized or poorly matched for a bath renovation?

Skip HomeWerks Worldwide 7140-110-G3 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

## Which guides and calculators connect next to HomeWerks Worldwide 7140-110-G3?

Follow the linked specification directories, state wage tables, and interactive tools below to verify permits, grants, and contractor bids for HomeWerks Worldwide 7140-110-G3.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [HomeWerks Worldwide 7141-110 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-110/)
- [HomeWerks Worldwide 7141-110-G4 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-110-g4/)
- [Akicon AK13110N4-W Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/akicon-ak13110n4-w/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator