Rated for 110 CFM open-air (94.2 CFM at 0.25 in. w.g.), HomeWerks Worldwide 7141-110-G4 registers #522 of 607 in quietness (2.0 sones) and delivers 4.4 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 94 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside HomeWerks Worldwide 7141-110-G4 Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 94.2 CFM

- **Noise @ 0.1"**: 2.0 sones (#522/607)

- **Efficacy Rank**: 4.4 CFM/W (#679/1,145)

- **Static Retention**: 85.6% @ 0.25"

- **Motor Draw**: 25.0 W (9.1 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does HomeWerks Worldwide 7141-110-G4 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 94.2 CFM out of 110 CFM (85.6% retention, 2.1 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside HomeWerks Worldwide's 31-unit lineup, 7141-110-G4 (series: 7141-110-G4) carries PD #2400224 dating to 2022-08-12. Lighting kit: Yes. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.0 watts, about 9.1 kWh/yr (~$1.46/yr at $0.16/kWh) for 1 hr/day shower timers or 219.0 kWh/yr (~$35.04/yr) continuously. Closest competing matches include Air King E80S (110.0 CFM) and Air King E80SH (110.0 CFM).

## How does HomeWerks Worldwide 7141-110-G4 acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against HomeWerks Worldwide 7141-110-G4 (2.0 sones).

## How do flex elbows choke HomeWerks Worldwide 7141-110-G4 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps HomeWerks Worldwide 7141-110-G4 moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does HomeWerks Worldwide 7141-110-G4 meet residential exhaust fan code specs?

Inspect HomeWerks Worldwide 7141-110-G4 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | HomeWerks Worldwide (31 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 7141-110-G4 / 7141-110-G4 | PD ID 2400224 (Qualified 2022-08-12) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (94.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (2.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## Which bathroom duties match HomeWerks Worldwide 7141-110-G4 airflow output?

Annual electricity figures and room square-footage ceilings below reflect HomeWerks Worldwide 7141-110-G4 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for HomeWerks Worldwide 7141-110-G4

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 94 sq ft | 1 CFM/sq ft @ 94.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 83 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 44 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.1 kWh/yr (~$1.46/yr) | 25.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 219.0 kWh/yr (~$35.04/yr) | 25.0 W x 8,760 hrs / 1,000 |

## Which competing models share HomeWerks Worldwide 7141-110-G4 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Air King E80S**](https://siematic-charleston.com/ventilation-fans/air-king-e80s/) | 110 / 115.9 CFM | Unpublished | 4.5 CFM/W | 6 in. diameter |
| [**Air King E80SH**](https://siematic-charleston.com/ventilation-fans/air-king-e80sh/) | 110 / 115.9 CFM | Unpublished | 4.5 CFM/W | 6 in. diameter |
| [**Win Air BPT14-24A-2**](https://siematic-charleston.com/ventilation-fans/win-air-bpt14-24a-2/) | 110 / 100.4 CFM | Unpublished | 4.5 CFM/W | 4 in. diameter |
| [**Commercial Electric BF1107**](https://siematic-charleston.com/ventilation-fans/commercial-electric-bf1107/) | 110 / 88.6 CFM | Unpublished | 4.3 CFM/W | 4 in. diameter |
| [**Akicon AK13110N4-B**](https://siematic-charleston.com/ventilation-fans/akicon-ak13110n4-b/) | 110 / 87.4 CFM | 2.0 sones (Same) | 4.2 CFM/W | 4 in. diameter |

## How much airflow margin does HomeWerks Worldwide 7141-110-G4 give your bath?

Run a quick local room-volume check for HomeWerks Worldwide 7141-110-G4 by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out HomeWerks Worldwide 7141-110-G4?

Compare where HomeWerks Worldwide 7141-110-G4 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 44 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Bathroom floor <= 94 sq ft with 8-ft ceilings (83 sq ft at 9-ft height)
- **Suited to:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What should homeowners verify first about HomeWerks Worldwide 7141-110-G4?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to HomeWerks Worldwide 7141-110-G4.

### Why might a contractor swap HomeWerks Worldwide 7141-110-G4 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, HomeWerks Worldwide 7141-110-G4 lacks adequate reserve.

### How does HomeWerks Worldwide 7141-110-G4 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., HomeWerks Worldwide 7141-110-G4 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

### Is HomeWerks Worldwide 7141-110-G4 quiet enough for a primary bedroom bathroom?

At 2.0 sones, HomeWerks Worldwide 7141-110-G4 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is HomeWerks Worldwide 7141-110-G4 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can HomeWerks Worldwide 7141-110-G4 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from HomeWerks Worldwide 7141-110-G4's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing HomeWerks Worldwide 7141-110-G4?

HomeWerks Worldwide 7141-110-G4 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change HomeWerks Worldwide 7141-110-G4's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing HomeWerks Worldwide 7141-110-G4's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can HomeWerks Worldwide 7141-110-G4 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: HomeWerks Worldwide 7141-110-G4 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

## Which GradeMark tools pair best with HomeWerks Worldwide 7141-110-G4?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to HomeWerks Worldwide 7141-110-G4.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [HomeWerks Worldwide 7148-110-G4 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7148-110-g4/)
- [Nektra Pro 33003855 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/nektra-pro-33003855/)
- [HomeWerks Worldwide 7141-110 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-110/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)