title: "HomeWerks Worldwide 7141-80-G4 Bath Fan (80 CFM, 1.1 Sone)"
url: https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-80-g4/
description: "ENERGY STAR specs for HomeWerks Worldwide 7141-80-G4: 80 CFM, 1.1 sones (#357 of 607), 3.7 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  HomeWerks Worldwide 7141-80-G4 Exhaust Fan Specifications

ENERGY STAR PD #2400085 · Bathroom/Utility Room · Qualified 2022-08-12

Verified Specification Summary

In EPA dataset 8dv7-nngq, HomeWerks Worldwide 7141-80-G4 tests at 80 CFM free discharge (61.2 CFM at 0.25 in. w.g.) and registers #357 of 607 in quietness (1.1 sones) and delivers 3.7 CFM/W efficacy, meeting residential IRC M1505 sizing up to 61 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside HomeWerks Worldwide 7141-80-G4 Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 61.2 CFM

- **Noise @ 0.1"**: 1.1 sones (#357/607)

- **Efficacy Rank**: 3.7 CFM/W (#987/1,145)

- **Static Retention**: 76.5% @ 0.25"

- **Motor Draw**: 21.6 W (7.9 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does HomeWerks Worldwide 7141-80-G4 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.1 sones (#357 of 607 rated models, 0.10 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 61.2 CFM at 0.25 in. w.g. (76.5% retention, 11.2 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places 7141-80-G4 (series: 7141-80-G4) (PD #2400085) among 31 HomeWerks Worldwide entries qualified through 2022-08-12. Lighting kit: Yes. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 21.6 watts, about 7.9 kWh/yr (~$1.26/yr at $0.16/kWh) for 1 hr/day shower timers or 189.2 kWh/yr (~$30.27/yr) continuously. Closest competing matches include Broan (Canada) EZ80C (80.0 CFM) and Utilitech 7105-08-L (80.0 CFM).

## Does HomeWerks Worldwide 7141-80-G4 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with HomeWerks Worldwide 7141-80-G4 at 1.1 sones.

## Why avoid unvented attic termination with HomeWerks Worldwide 7141-80-G4?

Under ASHRAE 62.2 best practice, HomeWerks Worldwide 7141-80-G4 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What installation parameters govern HomeWerks Worldwide 7141-80-G4?

Before cutting ceiling drywall or sizing attic transitions for HomeWerks Worldwide 7141-80-G4, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | HomeWerks Worldwide (31 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 7141-80-G4 / 7141-80-G4 | PD ID 2400085 (Qualified 2022-08-12) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (61.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.1 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What daily runtime and room footprint suit HomeWerks Worldwide 7141-80-G4?

Bathroom ventilation sizing below maps HomeWerks Worldwide 7141-80-G4 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for HomeWerks Worldwide 7141-80-G4

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 61 sq ft | 1 CFM/sq ft @ 61.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 54 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.9 kWh/yr (~$1.26/yr) | 21.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 189.2 kWh/yr (~$30.27/yr) | 21.6 W x 8,760 hrs / 1,000 |

## What peer models sit nearest HomeWerks Worldwide 7141-80-G4 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to HomeWerks Worldwide 7141-80-G4.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan (Canada) EZ80C**](https://siematic-charleston.com/ventilation-fans/broan-canada-ez80c-2406836/) | 80 / 65.6 CFM | 1.1 sones (Same) | 3.7 CFM/W | 4 in. diameter |
| [**Utilitech 7105-08-L**](https://siematic-charleston.com/ventilation-fans/utilitech-7105-08-l/) | 80 / 59.9 CFM | 1.1 sones (Same) | 3.5 CFM/W | 4 in. diameter |
| [**Commercial Electric 7132-12-CE**](https://siematic-charleston.com/ventilation-fans/commercial-electric-7132-12-ce/) | 80 / 57.1 CFM | 1.1 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| [**Broan EZ80**](https://siematic-charleston.com/ventilation-fans/broan-ez80-2248924/) | 80 / 65.6 CFM | 1.0 sones (-0.10) | 3.7 CFM/W | 4 in. diameter |
| [**Broan LP80**](https://siematic-charleston.com/ventilation-fans/broan-lp80-2248890/) | 80 / 65.6 CFM | 1.0 sones (-0.10) | 3.7 CFM/W | 4 in. diameter |

## What percentage of room demand does HomeWerks Worldwide 7141-80-G4 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against HomeWerks Worldwide 7141-80-G4 tested delivery.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out HomeWerks Worldwide 7141-80-G4?

Compare where HomeWerks Worldwide 7141-80-G4 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 61.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Target comfort around 1.1 sones up to 61 sq ft
- **Suited to:** Paired with rigid galvanized 4 in. diameter transition

## Where do official rules set limits for HomeWerks Worldwide 7141-80-G4?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing HomeWerks Worldwide 7141-80-G4.

### Is HomeWerks Worldwide 7141-80-G4 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can HomeWerks Worldwide 7141-80-G4 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from HomeWerks Worldwide 7141-80-G4's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing HomeWerks Worldwide 7141-80-G4?

HomeWerks Worldwide 7141-80-G4 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change HomeWerks Worldwide 7141-80-G4's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing HomeWerks Worldwide 7141-80-G4's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can HomeWerks Worldwide 7141-80-G4 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: HomeWerks Worldwide 7141-80-G4 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap HomeWerks Worldwide 7141-80-G4 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, HomeWerks Worldwide 7141-80-G4 lacks adequate reserve.

### How does HomeWerks Worldwide 7141-80-G4 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., HomeWerks Worldwide 7141-80-G4 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

### Is HomeWerks Worldwide 7141-80-G4 quiet enough for a primary bedroom bathroom?

At 1.1 sones, HomeWerks Worldwide 7141-80-G4 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

## What related resources expand on HomeWerks Worldwide 7141-80-G4?

Explore connected product catalogs, federal grant guides, and interactive estimators below before requesting written contractor proposals.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Utilitech 7105-08-L Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/utilitech-7105-08-l/)
- [Broan EZ80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/broan-ez80/)
- [HomeWerks Worldwide 7141-80 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-80/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)