title: "HomeWerks Worldwide 7148-110-G4 Bath Fan (110 CFM, 2.0 Sone)"
url: https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7148-110-g4/
description: "ENERGY STAR specs for HomeWerks Worldwide 7148-110-G4: 110 CFM, 2.0 sones (#522 of 607), 4.1 CFM/W, 4 in. diameter and 5 closest peer fans."
---

#  HomeWerks Worldwide 7148-110-G4 Exhaust Fan Specifications

ENERGY STAR PD #4610276 · Bathroom/Utility Room · Qualified 2026-03-25

Verified Specification Summary

Certified by EPA ENERGY STAR, HomeWerks Worldwide 7148-110-G4 delivers 110 CFM free-air (89.5 CFM at 0.25 in. w.g.) and registers #522 of 607 in quietness (2.0 sones) and delivers 4.1 CFM/W efficacy, clearing residential IRC M1505 sizing up to 89 sq ft (8-ft height) or 79 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside HomeWerks Worldwide 7148-110-G4 Exhaust Fan before installation.

- **Airflow @ 0.1" / 0.25"**: 110 / 89.5 CFM

- **Noise @ 0.1"**: 2.0 sones (#522/607)

- **Efficacy Rank**: 4.1 CFM/W (#821/1,145)

- **Static Retention**: 81.4% @ 0.25"

- **Motor Draw**: 26.8 W (9.8 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does HomeWerks Worldwide 7148-110-G4 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 89.5 CFM at 0.25 in. w.g. (81.4% retention, 6.3 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

HomeWerks Worldwide maintains 31 active ENERGY STAR blowers; 7148-110-G4 (series: 7148-110-G4) (PD #4610276) gained qualification on 2026-03-25. Lighting kit: Yes. At 4.1 CFM/W (#821 of 1,145, below median tier among 1,145 rated models; more efficient than 26.1% of rated models, 0.6 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.8 watts, about 9.8 kWh/yr (~$1.57/yr at $0.16/kWh) for 1 hr/day shower timers or 234.8 kWh/yr (~$37.57/yr) continuously. Closest competing matches include DewStop - Breeze Easy FL300-2W (110.0 CFM) and RAB CEP10S (110.0 CFM).

## How noisy is HomeWerks Worldwide 7148-110-G4 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while HomeWerks Worldwide 7148-110-G4 measures 2.0 sones across the 1,145-model registry.

## Why does rigid 4 in. diameter ducting protect HomeWerks Worldwide 7148-110-G4 airflow?

Connecting HomeWerks Worldwide 7148-110-G4 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify HomeWerks Worldwide 7148-110-G4 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for HomeWerks Worldwide 7148-110-G4 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | HomeWerks Worldwide (31 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 7148-110-G4 / 7148-110-G4 | PD ID 4610276 (Qualified 2026-03-25) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (89.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (2.0 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What room sizes and annual power draw fit HomeWerks Worldwide 7148-110-G4?

Calculated coverage metrics translate HomeWerks Worldwide 7148-110-G4 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for HomeWerks Worldwide 7148-110-G4

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 89 sq ft | 1 CFM/sq ft @ 89.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 79 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 39 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.8 kWh/yr (~$1.57/yr) | 26.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 234.8 kWh/yr (~$37.57/yr) | 26.8 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to HomeWerks Worldwide 7148-110-G4?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**DewStop - Breeze Easy FL300-2W**](https://siematic-charleston.com/ventilation-fans/dewstop-breeze-easy-fl300-2w/) | 110 / 89.7 CFM | Unpublished | 4.1 CFM/W | 4 in. diameter |
| [**RAB CEP10S**](https://siematic-charleston.com/ventilation-fans/rab-cep10s/) | 110 / 100.8 CFM | Unpublished | 4.1 CFM/W | 4 in. diameter |
| [**RAB CEP10SNL**](https://siematic-charleston.com/ventilation-fans/rab-cep10snl/) | 110 / 100.8 CFM | Unpublished | 4.1 CFM/W | 4 in. diameter |
| [**Commercial Electric BF1109**](https://siematic-charleston.com/ventilation-fans/commercial-electric-bf1109/) | 110 / 93.3 CFM | Unpublished | 4.0 CFM/W | 4 in. diameter |
| [**Commercial Electric BF1110**](https://siematic-charleston.com/ventilation-fans/commercial-electric-bf1110/) | 110 / 93.3 CFM | Unpublished | 4.0 CFM/W | 4 in. diameter |

## Does HomeWerks Worldwide 7148-110-G4 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check HomeWerks Worldwide 7148-110-G4 percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does HomeWerks Worldwide 7148-110-G4 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying HomeWerks Worldwide 7148-110-G4 for your remodel.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 39 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Strong scenario:** Moisture load fits 89.5 CFM net static output
- **Best application:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for HomeWerks Worldwide 7148-110-G4?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around HomeWerks Worldwide 7148-110-G4.

### How many kWh per year does HomeWerks Worldwide 7148-110-G4 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, HomeWerks Worldwide 7148-110-G4 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can HomeWerks Worldwide 7148-110-G4 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from HomeWerks Worldwide 7148-110-G4's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing HomeWerks Worldwide 7148-110-G4?

HomeWerks Worldwide 7148-110-G4 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change HomeWerks Worldwide 7148-110-G4's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing HomeWerks Worldwide 7148-110-G4's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does HomeWerks Worldwide 7148-110-G4 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), HomeWerks Worldwide 7148-110-G4 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install HomeWerks Worldwide 7148-110-G4 in a bathroom remodel?

Avoid specifying HomeWerks Worldwide 7148-110-G4 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut HomeWerks Worldwide 7148-110-G4 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, HomeWerks Worldwide 7148-110-G4 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

### What acoustic sone tier does HomeWerks Worldwide 7148-110-G4 occupy in EPA filings?

With 2.0 sones at 0.1 in. w.g., HomeWerks Worldwide 7148-110-G4 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

## Where can you explore more benchmarks around HomeWerks Worldwide 7148-110-G4?

Use the related reference pages and estimators below to cross-check HomeWerks Worldwide 7148-110-G4 against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Nektra Pro 33003855 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/nektra-pro-33003855/)
- [Wintek BPT13B-110N4 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/wintek-bpt13b-110n4/)
- [HomeWerks Worldwide 7141-110-G4 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/homewerks-worldwide-7141-110-g4/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)