title: "Hunter 90065A Bath Fan (100 CFM, 1.5 Sone) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/hunter-90065a/
description: "ENERGY STAR specs for Hunter 90065A: 100 CFM, 1.5 sones (#412 of 607), 3.9 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks."
---

#  Hunter 90065A Exhaust Fan Specifications

ENERGY STAR PD #4498421 · Bathroom/Utility Room · Qualified 2025-09-05

Verified Specification Summary

Certified by EPA ENERGY STAR, Hunter 90065A delivers 100 CFM free-air (89.6 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 3.9 CFM/W efficacy, clearing residential IRC M1505 sizing up to 89 sq ft (8-ft height) or 79 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Hunter 90065A Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 100 / 89.6 CFM

- **Noise @ 0.1"**: 1.5 sones (#412/607)

- **Efficacy Rank**: 3.9 CFM/W (#876/1,145)

- **Static Retention**: 89.6% @ 0.25"

- **Motor Draw**: 25.6 W (9.3 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Hunter 90065A vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 89.6 CFM out of 100 CFM (89.6% retention, 1.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #4498421 verifies 90065A (series: 90065A) under Hunter (4 listed models, qualified 2025-09-05). Lighting kit: Yes. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include Anzzi EF-AZ106MB (100.0 CFM) and Anzzi EF-AZ106WH (100.0 CFM).

## How noisy is Hunter 90065A compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Hunter 90065A measures 1.5 sones across the 1,145-model registry.

## Why does rigid 4 in. diameter ducting protect Hunter 90065A airflow?

Connecting Hunter 90065A through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## What laboratory specs verify Hunter 90065A performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Hunter 90065A lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Hunter (4 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 90065A / 90065A | PD ID 4498421 (Qualified 2025-09-05) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (89.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | NO (1.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## What room sizes and annual power draw fit Hunter 90065A?

Calculated coverage metrics translate Hunter 90065A airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Hunter 90065A

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 89 sq ft | 1 CFM/sq ft @ 89.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 79 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 39 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.3 kWh/yr (~$1.49/yr) | 25.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 224.3 kWh/yr (~$35.89/yr) | 25.6 W x 8,760 hrs / 1,000 |

## What alternative bath fans offer similar CFM to Hunter 90065A?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Anzzi EF-AZ106MB**](https://siematic-charleston.com/ventilation-fans/anzzi-ef-az106mb/) | 100 / 92.8 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| [**Anzzi EF-AZ106WH**](https://siematic-charleston.com/ventilation-fans/anzzi-ef-az106wh/) | 100 / 92.8 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| [**Fantech SMPL100 (484302)**](https://siematic-charleston.com/ventilation-fans/fantech-smpl100-484302/) | 100 / 91.2 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| [**Fantech SMPL100L (484303)**](https://siematic-charleston.com/ventilation-fans/fantech-smpl100l-484303/) | 100 / 91.2 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| [**ACIQ AES100**](https://siematic-charleston.com/ventilation-fans/aciq-aes100/) | 100 / 90.2 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |

## Does Hunter 90065A match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Hunter 90065A percentage capacity without sending data.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Hunter 90065A?

Compare where Hunter 90065A excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 39 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Moisture load fits 89.6 CFM net static output
- **Suited to:** Collar pairs with 4 in. diameter duct straight outdoors

## Which homeowner questions come up most for Hunter 90065A?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Hunter 90065A.

### Is Hunter 90065A quiet enough for a primary bedroom bathroom?

At 1.5 sones, Hunter 90065A produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Hunter 90065A energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Hunter 90065A pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Hunter 90065A's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Hunter 90065A?

Hunter 90065A features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Hunter 90065A's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Hunter 90065A's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Hunter 90065A serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Hunter 90065A supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Hunter 90065A for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Hunter 90065A lacks adequate reserve.

### How does Hunter 90065A handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Hunter 90065A yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

## Where can you explore more benchmarks around Hunter 90065A?

Use the related reference pages and estimators below to cross-check Hunter 90065A against state labor wages, WaterSense rebates, and federal grant rules.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [S&P PCLP100XP Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/s-p-pclp100xp/)
- [Utilitech 7115-01 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/utilitech-7115-01/)
- [Hunter 90064A Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/hunter-90064a/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)