Verified Specification Summary

Rated for 80 CFM open-air (70.5 CFM at 0.25 in. w.g.), Hunter 90705 registers #107 of 607 in quietness (0.6 sones) and delivers 3.5 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 70 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Hunter 90705 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 80 / 70.5 CFM

- **Noise @ 0.1"**: 0.6 sones (#107/607)

- **Efficacy Rank**: 3.5 CFM/W (#1,038/1,145)

- **Static Retention**: 88.1% @ 0.25"

- **Motor Draw**: 22.9 W (8.4 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Hunter 90705 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.6 sones (#107 of 607 rated models, quietest 22.1% of 607 rated models, quieter than 77.9% of rated models, 0.40 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 70.5 CFM out of 80 CFM (88.1% retention, 0.4 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places 90705 (series: 90705) (PD #4498418) among 4 Hunter entries qualified through 2025-09-05. Lighting kit: Yes. At 3.5 CFM/W (#1,038 of 1,145, below median tier among 1,145 rated models; more efficient than 7.5% of rated models, 1.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.9 watts, about 8.4 kWh/yr (~$1.34/yr at $0.16/kWh) for 1 hr/day shower timers or 200.6 kWh/yr (~$32.10/yr) continuously. Closest competing matches include Broan AE80 (80.0 CFM) and Broan AE80K (80.0 CFM).

## How does Hunter 90705 acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Hunter 90705 (0.6 sones).

## How do flex elbows choke Hunter 90705 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Hunter 90705 moving full rated CFM.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Does Hunter 90705 meet residential exhaust fan code specs?

Inspect Hunter 90705 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Hunter (4 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 90705 / 90705 | PD ID 4498418 (Qualified 2025-09-05) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (70.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.6 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | Yes | Verify switched neutral wiring |

## Which bathroom duties match Hunter 90705 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Hunter 90705 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Hunter 90705

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 70 sq ft | 1 CFM/sq ft @ 70.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 62 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 20 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.4 kWh/yr (~$1.34/yr) | 22.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 200.6 kWh/yr (~$32.10/yr) | 22.9 W x 8,760 hrs / 1,000 |

## Which competing models share Hunter 90705 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan AE80**](https://siematic-charleston.com/ventilation-fans/broan-ae80/) | 80 / 74.5 CFM | 0.6 sones (Same) | 3.9 CFM/W | 6 in. diameter |
| [**Broan AE80K**](https://siematic-charleston.com/ventilation-fans/broan-ae80k-2369230/) | 80 / 74.5 CFM | 0.6 sones (Same) | 3.9 CFM/W | 6 in. diameter |
| [**Broan AE80K = A000HFKT with AE80KF**](https://siematic-charleston.com/ventilation-fans/broan-ae80k-a000hfkt-with-ae80kf/) | 80 / 74.5 CFM | 0.6 sones (Same) | 3.9 CFM/W | 6 in. diameter |
| [**Broan AE80K = A000HFKTC WITH AE80KF**](https://siematic-charleston.com/ventilation-fans/broan-ae80k-a000hfktc-with-ae80kf/) | 80 / 74.5 CFM | 0.6 sones (Same) | 3.9 CFM/W | 6 in. diameter |
| [**Broan AE80K = A000HFNF with AE80KF**](https://siematic-charleston.com/ventilation-fans/broan-ae80k-a000hfnf-with-ae80kf/) | 80 / 74.5 CFM | 0.6 sones (Same) | 3.9 CFM/W | 6 in. diameter |

## How much airflow margin does Hunter 90705 give your bath?

Run a quick local room-volume check for Hunter 90705 by entering square footage and ceiling height to spot under-vented steam risks early.

Bathroom Area (sq ft)

Ceiling Height (ft)

## When does Hunter 90705 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Hunter 90705.

### Limitations & Who Should Skip

- Steam or walk-in tub room > 20 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex

### Best-Fit Homeowner Profiles

- **Recommended when:** Bathroom floor <= 70 sq ft with 8-ft ceilings (62 sq ft at 9-ft height)
- **Target scenario:** Exterior run uses smooth rigid metal matched to 4 in. diameter

## What should homeowners verify first about Hunter 90705?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Hunter 90705.

### Is Hunter 90705 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Hunter 90705 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

### Which bathroom layouts should pick a larger blower than Hunter 90705?

Do not force Hunter 90705 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

### How much airflow does Hunter 90705 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Hunter 90705 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

### Will Hunter 90705 disturb adjacent bedrooms during night use?

Acoustic measurement places Hunter 90705 at 0.6 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

### Does running Hunter 90705 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Hunter 90705 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

### Can Hunter 90705 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Hunter 90705's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Hunter 90705?

Hunter 90705 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Hunter 90705's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Hunter 90705's safe coverage footprint from 50 sq ft to 44 sq ft.

## Which GradeMark tools pair best with Hunter 90705?

Open related specification pages, county profiles, and cost estimators below to validate bids and building codes connected to Hunter 90705.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Tech Drive TD-BF-04-plus Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/tech-drive-td-bf-04-plus/)
- [VENTECHLATION VF-BF-03 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ventechlation-vf-bf-03/)
- [Hunter 90704 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/hunter-90704/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)