#  Kaze Appliance SEP150 Exhaust Fan Specifications

ENERGY STAR PD #2546735 · Bathroom/Utility Room · Qualified 2023-06-23

Verified Specification Summary

Tested under HVI protocols, the Kaze Appliance SEP150 exhaust unit achieves 150 CFM at 0.1 in. w.g. (123.8 CFM at 0.25 in. w.g.), registers #83 of 607 in quietness (0.5 sones) and delivers 4.6 CFM/W efficacy, covering standard baths up to 123 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Kaze Appliance SEP150 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 150 / 123.8 CFM

- **Noise @ 0.1"**: 0.5 sones (#83/607)

- **Efficacy Rank**: 4.6 CFM/W (#578/1,145)

- **Static Retention**: 82.5% @ 0.25"

- **Motor Draw**: 32.6 W (11.9 kWh/yr)

- **Duct & Tier**: 6 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does Kaze Appliance SEP150 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.5 sones (#83 of 607 rated models, quietest 17.5% of 607 rated models, quieter than 82.5% of rated models, 0.50 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 150 CFM open-air to 123.8 CFM at 0.25 in. w.g. (82.5% retention, 5.2 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #2546735 verifies SEP150 (series: SEP) under Kaze Appliance (4 listed models, qualified 2023-06-23). Lighting kit: No. At 4.6 CFM/W (#578 of 1,145, below median tier among 1,145 rated models; more efficient than 44.9% of rated models, 0.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 32.6 watts, about 11.9 kWh/yr (~$1.90/yr at $0.16/kWh) for 1 hr/day shower timers or 285.6 kWh/yr (~$45.70/yr) continuously. Closest competing matches include ACIQ AEP150 (150.0 CFM) and Anzzi EF-AZ104WH (150.0 CFM).

## Where do Kaze Appliance SEP150 sones rank across EPA ENERGY STAR fans?

Comparing Kaze Appliance SEP150 (0.5 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

## What attic duct routing preserves Kaze Appliance SEP150 CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Kaze Appliance SEP150, preventing premature peeling paint and mold growth.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## How does Kaze Appliance SEP150 measure up on airflow and noise ratings?

Each row below breaks down Kaze Appliance SEP150 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | Kaze Appliance (4 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | SEP150 / SEP | PD ID 2546735 (Qualified 2023-06-23) |
| **Duct Connection** | 6 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (123.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | YES (0.5 sones) | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## How does ceiling height affect Kaze Appliance SEP150 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Kaze Appliance SEP150

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 123 sq ft | 1 CFM/sq ft @ 123.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 110 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 73 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 11.9 kWh/yr (~$1.90/yr) | 32.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 285.6 kWh/yr (~$45.70/yr) | 32.6 W x 8,760 hrs / 1,000 |

## How do nearby ENERGY STAR blowers compare against Kaze Appliance SEP150?

Compare Kaze Appliance SEP150 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**ACIQ AEP150**](https://siematic-charleston.com/ventilation-fans/aciq-aep150/) | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| [**Anzzi EF-AZ104WH**](https://siematic-charleston.com/ventilation-fans/anzzi-ef-az104wh/) | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| [**Anzzi EF-AZ105WH**](https://siematic-charleston.com/ventilation-fans/anzzi-ef-az105wh/) | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| [**Cyclone ESCBP150**](https://siematic-charleston.com/ventilation-fans/cyclone-escbp150/) | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| [**Ortech OD-1505PB**](https://siematic-charleston.com/ventilation-fans/ortech-od-1505pb/) | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |

## Can you size Kaze Appliance SEP150 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Kaze Appliance SEP150 verified capacity.

Bathroom Area (sq ft)

Ceiling Height (ft)

## What plumbing or duct constraints rule out Kaze Appliance SEP150?

Compare where Kaze Appliance SEP150 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

### Limitations & Who Should Skip

- High-ceiling bath (10+ ft) pushing demand past 123.8 CFM
- Sharp multiple 90-degree flex bends choking static pressure

### Best-Fit Homeowner Profiles

- **Homeowner profile:** Target comfort around 0.5 sones up to 123 sq ft
- **Suited to:** Paired with rigid galvanized 6 in. diameter transition

## How do federal and code standards apply to Kaze Appliance SEP150?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Kaze Appliance SEP150.

### How does Kaze Appliance SEP150 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Kaze Appliance SEP150 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

### Is Kaze Appliance SEP150 quiet enough for a primary bedroom bathroom?

At 0.5 sones, Kaze Appliance SEP150 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

### Is Kaze Appliance SEP150 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

### Can Kaze Appliance SEP150 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Kaze Appliance SEP150's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing Kaze Appliance SEP150?

Kaze Appliance SEP150 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change Kaze Appliance SEP150's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Kaze Appliance SEP150's safe coverage footprint from 50 sq ft to 44 sq ft.

### Can Kaze Appliance SEP150 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Kaze Appliance SEP150 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

### Why might a contractor swap Kaze Appliance SEP150 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Kaze Appliance SEP150 lacks adequate reserve.

## What neighboring pages and tools support Kaze Appliance SEP150?

Jump to adjacent product series, state licensing directories, and browser calculators linked below to finish planning around Kaze Appliance SEP150.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [Ortech OD-1505PB Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/ortech-od-1505pb/)
- [S&P PC150XP Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/s-p-pc150xp/)
- [Delta 150LED-ADJ Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-150led-adj/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)