---
title: "KOHLER 34454 Bath Fan (130 CFM) | GradeMark"
url: https://siematic-charleston.com/ventilation-fans/kohler-34454/
description: "ENERGY STAR specs for KOHLER 34454: 130 CFM, 3.9 CFM/W, 4 in. diameter and 5 closest peer fans. Verified US agency benchmarks, engineering codes, and."
---

#  KOHLER 34454 Exhaust Fan Specifications

ENERGY STAR PD #3626814 · Bathroom/Utility Room · Qualified 2024-08-30

Verified Specification Summary

Homeowners specifying KOHLER 34454 gain 130 CFM at 0.1 in. w.g. (106 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 3.9 CFM/W efficacy, venting bathrooms up to 106 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside KOHLER 34454 Exhaust Fan Specifications before installation.

- **Airflow @ 0.1" / 0.25"**: 130 / 106 CFM

- **Noise @ 0.1"**: Unpublished

- **Efficacy Rank**: 3.9 CFM/W (#876/1,145)

- **Static Retention**: 81.5% @ 0.25"

- **Motor Draw**: 33.3 W (12.2 kWh/yr)

- **Duct & Tier**: 4 in. diameter · Standard

Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

## What does KOHLER 34454 vs. 1,145-Model ENERGY STAR Benchmarks show?

KOHLER 34454 (EPA filing PD #3626814) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 130 CFM open-air to 106 CFM at 0.25 in. w.g. (81.5% retention, 6.2 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside KOHLER's 32-unit lineup, 34454 (series: ATMO) carries PD #3626814 dating to 2024-08-30. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 33.3 watts, about 12.2 kWh/yr (~$1.95/yr at $0.16/kWh) for 1 hr/day shower timers or 291.7 kWh/yr (~$46.67/yr) continuously. Closest competing matches include Broan QT130LE (130.0 CFM) and Nutone QTN130LE1 (130.0 CFM).

## Which exterior damper path suits KOHLER 34454 best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around KOHLER 34454 housings.

Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

## Where do KOHLER 34454 acoustic and static metrics stand?

Compare KOHLER 34454 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks

| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| **Manufacturer / Brand Share** | KOHLER (32 models) | ENERGY STAR Certified Partner |
| **Model Number & Series** | 34454 / ATMO | PD ID 3626814 (Qualified 2024-08-30) |
| **Duct Connection** | 4 in. diameter | Use smooth rigid metal outdoors |
| **IRC M1505 (>=50 CFM) Check** | PASS (106 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| **Acoustic Suite (<=1.0 Sone)** | Unpublished | Fleet median 1.0 sones |
| **Integrated Lighting** | No | Verify switched neutral wiring |

## Can KOHLER 34454 handle taller ceilings or walk-in tub steam?

Evaluate how KOHLER 34454 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for KOHLER 34454

| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 106 sq ft | 1 CFM/sq ft @ 106 CFM |
| Tall Bath (9-ft Ceiling) | Up to 94 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 56 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.2 kWh/yr (~$1.95/yr) | 33.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 291.7 kWh/yr (~$46.67/yr) | 33.3 W x 8,760 hrs / 1,000 |

## Are quieter or higher-efficacy peers available near KOHLER 34454?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy

| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| [**Broan QT130LE**](https://siematic-charleston.com/ventilation-fans/broan-qt130le-2404744/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Nutone QTN130LE1**](https://siematic-charleston.com/ventilation-fans/nutone-qtn130le1/) | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| [**Broan QT130E**](https://siematic-charleston.com/ventilation-fans/broan-qt130e-4429508/) | 130 / 130.4 CFM | 1.5 sones | 4.7 CFM/W | 6 in. diameter |
| [**Greenheck SP-B110ES**](https://siematic-charleston.com/ventilation-fans/greenheck-sp-b110es/) | 118 / 100 CFM | 1.5 sones | 4.0 CFM/W | 6 in. diameter |
| [**KORA SBF110N**](https://siematic-charleston.com/ventilation-fans/kora-sbf110n/) | 119.2 / N/A CFM | 1.6 sones | 3.5 CFM/W | 4 in. diameter |

## Is KOHLER 34454 sized right for your shower or tub room?

Check whether KOHLER 34454 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Bathroom Area (sq ft)

Ceiling Height (ft)

## Does KOHLER 34454 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying KOHLER 34454 for your remodel.

### Limitations & Who Should Skip

- Enclosed jetted tub exceeds 56 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper

### Best-Fit Homeowner Profiles

- **Strong scenario:** Moisture load fits 106 CFM net static output
- **Best application:** Collar pairs with 4 in. diameter duct straight outdoors

## Which code checks and cost facts matter for KOHLER 34454?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to KOHLER 34454.

### What acoustic sone tier does KOHLER 34454 occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., KOHLER 34454 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

### How many kWh per year does KOHLER 34454 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, KOHLER 34454 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

### Can KOHLER 34454 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from KOHLER 34454's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

### What duct diameter and termination rules apply when installing KOHLER 34454?

KOHLER 34454 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

### How does ceiling height above 8 feet change KOHLER 34454's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing KOHLER 34454's safe coverage footprint from 50 sq ft to 44 sq ft.

### Does KOHLER 34454 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), KOHLER 34454 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

### Who should NOT install KOHLER 34454 in a bathroom remodel?

Avoid specifying KOHLER 34454 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

### Does duct resistance cut KOHLER 34454 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, KOHLER 34454 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

## How can you cross-check KOHLER 34454 against local rules?

Browse linked state atlases, peer pages, and local budget calculators below to confirm regional applicability for KOHLER 34454.

- [Calculate exact bathroom CFM & duct elbows](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
- [Browse all 1,145 ENERGY STAR fan models](https://siematic-charleston.com/ventilation-fans/)
- [Prevent bathroom ceiling condensation & peeling paint](https://siematic-charleston.com/is-it-normal/bathroom-ceiling-condensation-peeling-paint/)
- [KOHLER 34454-NA Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kohler-34454-na/)
- [KOHLER 34455 Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/kohler-34455/)
- [Delta SMT130M Exhaust Fan Specifications](https://siematic-charleston.com/ventilation-fans/delta-smt130m/)

## Sources

1. [ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq)](https://data.energystar.gov/resource/8dv7-nngq.json) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
2. [DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC)](https://basc.pnnl.gov/resource-guides/bathroom-exhaust-fans) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

On This Page

- 01. Summary Verdict
- 02. Key Specs
- 03. Benchmark Notes
- 04. Full Specifications
- 05. Computed Outputs
- 06. Peer Alternatives
- 07. Fit Calculator
- 08. FAQ

Verification Tools

### Compare All 1,145 Exhaust Fans

Filter fans by exact duct diameter, static loss, and <= 1.0 sone quietness.
[Open CFM & Duct Tool](https://siematic-charleston.com/tools/bathroom-exhaust-fan-cfm-calculator/)
